Author
A. A. Garcia-Granada
Bio: A. A. Garcia-Granada is an academic researcher from University of Bristol. The author has contributed to research in topics: Residual stress & Fracture (geology). The author has an hindex of 10, co-authored 20 publications receiving 255 citations.
Papers
More filters
••
TL;DR: In this paper, a Fourier series is used to represent the residual stresses in cylindrical components and the correctness of the new procedure is demonstrated using a finite element simulation where a set of non-axisymmetric residual stresses are determined.
49 citations
••
TL;DR: In this article, the authors used a three-dimensional finite element model of a cold expanded hole combined with a Paris law fit to fatigue data derived from tests for corner cracks emanating from a plain hole.
43 citations
••
TL;DR: In this article, the incremental hole drilling (IHD) technique is tested to measure residual stresses, being able to reach a 2-mm measuring depth, and a commercial strain gage is used and calibrated using finite element model simulations.
Abstract: Ball-burnishing induces compressive residual stresses on treated materials by the effect of plastic deformation. The result is an increase in the fatigue life of the treated part, retarding the initiation of cracks on the surface. Compressive residual stresses have been previously measured by X-ray diffraction near the surface, revealing considerably high values at the maximum analyzed depth, in relation to other finishing processes such as shot peening. However, the maximum analyzed depth is very limited by using this technique. In this paper, the incremental hole drilling (IHD) technique is tested to measure residual stresses, being able to reach a 2-mm measuring depth. To that objective, a commercial strain gage is used and calibrated using finite element model simulations. A second Finite Element Model based on material removal rate is developed to obtain the equations to calculate the strain release through IHD. Finally, residual stresses are measured experimentally with that technique on two...
35 citations
••
TL;DR: An osteogenesis-on-a-chip device that comprises a 3D environment and fluid shear stresses, both important features of bone is developed to aid the development of ‘next-generation’ tools for investigating novel therapeutics for bone in comparison with standard laboratory and animal testing.
Abstract: Microfluidic-based tissue-on-a-chip devices have generated significant research interest for biomedical applications, such as pharmaceutical development, as they can be used for small volume, high throughput studies on the effects of therapeutics on tissue-mimics. Tissue-on-a-chip devices are evolving from basic 2D cell cultures incorporated into microfluidic devices to complex 3D approaches, with modern designs aimed at recapitulating the dynamic and mechanical environment of the native tissue. Thus far, most tissue-on-a-chip research has concentrated on organs involved with drug uptake, metabolism and removal (e.g., lung, skin, liver, and kidney); however, models of the drug metabolite target organs will be essential to provide information on therapeutic efficacy. Here, we develop an osteogenesis-on-a-chip device that comprises a 3D environment and fluid shear stresses, both important features of bone. This inexpensive, easy-to-fabricate system based on a polymerized High Internal Phase Emulsion (polyHIPE) supports proliferation, differentiation and extracellular matrix production of human embryonic stem cell-derived mesenchymal progenitor cells (hES-MPs) over extended time periods (up to 21 days). Cells respond positively to both chemical and mechanical stimulation of osteogenesis, with an intermittent flow profile containing rest periods strongly promoting differentiation and matrix formation in comparison to static and continuous flow. Flow and shear stresses were modeled using computational fluid dynamics. Primary cilia were detectable on cells within the device channels demonstrating that this mechanosensory organelle is present in the complex 3D culture environment. In summary, this device aids the development of ‘next-generation’ tools for investigating novel therapeutics for bone in comparison with standard laboratory and animal testing.
31 citations
••
TL;DR: In this article, the effect of layer orientation on the mixed-mode I/II fracture behavior of additively manufactured poly-carbonate produced using a fused deposition modelling (FDM) printer is investigated.
30 citations
Cited by
More filters
••
31 Oct 2001
TL;DR: The American Society for Testing and Materials (ASTM) as mentioned in this paper is an independent organization devoted to the development of standards for testing and materials, and is a member of IEEE 802.11.
Abstract: The American Society for Testing and Materials (ASTM) is an independent organization devoted to the development of standards.
3,792 citations
•
TL;DR: Validity and reliability are two important characteristics of behavioral measure and are referred to as credibility and reliability.
Abstract: For the statistical consultant working with social science researchers the estimation of reliability and validity is a task frequently encountered. Measurement issues differ in the social sciences in that they are related to the quantification of abstract, intangible and unobservable constructs. In many instances, then, the meaning of quantities is only inferred. Let us begin by a general description of the paradigm that we are dealing with. Most concepts in the behavioral sciences have meaning within the context of the theory that they are a part of. Each concept, thus, has an operational definition which is governed by the overarching theory. If a concept is involved in the testing of hypothesis to support the theory it has to be measured. So the first decision that the research is faced with is \" how shall the concept be measured? \" That is the type of measure. At a very broad level the type of measure can be observational, self-report, interview, etc. These types ultimately take shape of a more specific form like observation of ongoing activity, observing video-taped events, self-report measures like questionnaires that can be open-ended or close-ended, Likert-type scales, interviews that are structured, semi-structured or unstructured and open-ended or close-ended. Needless to say, each type of measure has specific types of issues that need to be addressed to make the measurement meaningful, accurate, and efficient. Another important feature is the population for which the measure is intended. This decision is not entirely dependent on the theoretical paradigm but more to the immediate research question at hand. 6/14/2016 2 A third point that needs mentioning is the purpose of the scale or measure. What is it that the researcher wants to do with the measure? Is it developed for a specific study or is it developed with the anticipation of extensive use with similar populations? Once some of these decisions are made and a measure is developed, which is a careful and tedious process, the relevant questions to raise are \" how do we know that we are indeed measuring what we want to measure? \" since the construct that we are measuring is abstract, and \" can we be sure that if we repeated the measurement we will get the same result? \". The first question is related to validity and second to reliability. Validity and reliability are two important characteristics of behavioral measure and are referred to as …
939 citations
01 Feb 2011
TL;DR: Optimal stent geometries and surfaces, as demonstrated with thin stent struts, help reduce the potential for thrombosis despite complex stent configurations and variability in deployment.
Abstract: Background—Stent thrombosis is a lethal complication of endovascular intervention. Concern has been raised about the inherent risk associated with specific stent designs and drug-eluting coatings, yet clinical and animal support is equivocal. Methods and Results—We examined whether drug-eluting coatings are inherently thrombogenic and if the response to these materials was determined to a greater degree by stent design and deployment with custom-built stents. Drug/polymer coatings uniformly reduce rather than increase thrombogenicity relative to matched bare metal counterparts (0.65-fold; P=0.011). Thick-strutted (162 μm) stents were 1.5-fold more thrombogenic than otherwise identical thin-strutted (81 μm) devices in ex vivo flow loops (P<0.001), commensurate with 1.6-fold greater thrombus coverage 3 days after implantation in porcine coronary arteries (P=0.004). When bare metal stents were deployed in malapposed or overlapping configurations, thrombogenicity increased compared with apposed, length-matche...
539 citations
••
TL;DR: In this paper, a non-destructive method for measuring residual stresses in structural engineering components is described. But the method is not suitable for the analysis of the residual stress distributions introduced by welding and the beneficial stresses produced by autofrettage, cold hole expansion and shot peening.
385 citations
01 Aug 2010
TL;DR: Stereolithography is a solid freeform technique (SFF) that was introduced in the late 1980s as discussed by the authors, which has the highest fabrication accuracy and an increasing number of materials that can be processed is becoming available.
Abstract: Stereolithography is a solid freeform technique (SFF) that was introduced in the late 1980s Although many other techniques have been developed since then, stereolithography remains one of the most powerful and versatile of all SFF techniques It has the highest fabrication accuracy and an increasing number of materials that can be processed is becoming available In this paper we discuss the characteristic features of the stereolithography technique and compare it to other SFF techniques The biomedical applications of stereolithography are reviewed, as well as the biodegradable resin materials that have been developed for use with stereolithography Finally, an overview of the application of stereolithography in preparing porous structures for tissue engineering is given
319 citations