A. D. White

Bio: A. D. White is an academic researcher from Bell Labs. The author has contributed to research in topics: Wavefront & Interferometry. The author has an hindex of 5, co-authored 5 publications receiving 2448 citations.

Papers
More filters
Journal Article
TL;DR: In this article, a self-scanned 1024 element photodiode array and a minicomputer are used to measure the phase (wavefront) in the interference pattern of an interferometer to lambda/100.
Abstract: A self-scanned 1024 element photodiode array and minicomputer are used to measure the phase (wavefront) in the interference pattern of an interferometer to lambda/100. The photodiode array samples intensities over a 32 x 32 matrix in the interference pattern as the length of the reference arm is varied piezoelectrically. Using these data the minicomputer synchronously detects the phase at each of the 1024 points by a Fourier series method and displays the wavefront in contour and perspective plot on a storage oscilloscope in less than 1 min (Bruning et al. Paper WE16, OSA Annual Meeting, Oct. 1972). The array of intensities is sampled and averaged many times in a random fashion so that the effects of air turbulence, vibrations, and thermal drifts are minimized. Very significant is the fact that wavefront errors in the interferometer are easily determined and may be automatically subtracted from current or subsequent wavefrots. Various programs supporting the measurement system include software for determining the aperture boundary, sum and difference of wavefronts, removal or insertion of tilt and focus errors, and routines for spatial manipulation of wavefronts. FFT programs transform wavefront data into point spread function and modulus and phase of the optical transfer function of lenses. Display programs plot these functions in contour and perspective. The system has been designed to optimize the collection of data to give higher than usual accuracy in measuring the individual elements and final performance of assembled diffraction limited optical systems, and furthermore, the short loop time of a few minutes makes the system an attractive alternative to constraints imposed by test glasses in the optical shop.

1,300 citations

Journal ArticleDOI
TL;DR: The system has been designed to optimize the collection of data to give higher than usual accuracy in measuring the individual elements and final performance of assembled diffraction limited optical systems, and furthermore, the short loop time of a few minutes makes the system an attractive alternative to constraints imposed by test glasses in the optical shop.
Abstract: A self-scanned 1024 element photodiode array and minicomputer are used to measure the phase (wavefront) in the interference pattern of an interferometer to lambda/100. The photodiode array samples intensities over a 32 x 32 matrix in the interference pattern as the length of the reference arm is varied piezoelectrically. Using these data the minicomputer synchronously detects the phase at each of the 1024 points by a Fourier series method and displays the wavefront in contour and perspective plot on a storage oscilloscope in less than 1 min (Bruning et al. Paper WE16, OSA Annual Meeting, Oct. 1972). The array of intensities is sampled and averaged many times in a random fashion so that the effects of air turbulence, vibrations, and thermal drifts are minimized. Very significant is the fact that wavefront errors in the interferometer are easily determined and may be automatically subtracted from current or subsequent wavefrots. Various programs supporting the measurement system include software for determining the aperture boundary, sum and difference of wavefronts, removal or insertion of tilt and focus errors, and routines for spatial manipulation of wavefronts. FFT programs transform wavefront data into point spread function and modulus and phase of the optical transfer function of lenses. Display programs plot these functions in contour and perspective. The system has been designed to optimize the collection of data to give higher than usual accuracy in measuring the individual elements and final performance of assembled diffraction limited optical systems, and furthermore, the short loop time of a few minutes makes the system an attractive alternative to constraints imposed by test glasses in the optical shop.

1,206 citations

Journal ArticleDOI
A. D. White1

20 citations

Journal ArticleDOI
A. D. White1

8 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: A new method is proposed in which the distribution of complex amplitude at a plane is measured by phase-shifting interferometry and then Fresnel transformed by a digital computer, which can reconstruct an arbitrary cross section of a three-dimensional object with higher image quality and a wider viewing angle than from conventional digital holography using an off-axis configuration.
Abstract: A new method for three-dimensional image formation is proposed in which the distribution of complex amplitude at a plane is measured by phase-shifting interferometry and then Fresnel transformed by a digital computer. The method can reconstruct an arbitrary cross section of a three-dimensional object with higher image quality and a wider viewing angle than from conventional digital holography using an off-axis configuration. Basic principles and experimental verification are described.

1,813 citations

Book ChapterDOI
TL;DR: The phase modulation in an interferometer can be induced by moving a mirror, tilting a glass plate, moving a grating, rotating a half-wave plate or analyzer, using an acoustooptic or electro-optic modulator, or using a Zeeman laser as mentioned in this paper.
Abstract: Publisher Summary This chapter describes the phase-measurement interferometry techniques. For all techniques, a temporal phase modulation is introduced to perform the measurement. By measuring the interferogram intensity as the phase is shifted, the phase of the wavefront can be determined with the aid of electronics or a computer. Phase modulation in an interferometer can be induced by moving a mirror, tilting a glass plate, moving a grating, rotating a half-wave plate or analyzer, using an acousto-optic or electro-optic modulator, or using a Zeeman laser. Phase-measurement techniques using analytical means to determine phase all have some common denominators. There are different equations for calculating the phase of a wavefront from interference fringe intensity measurements. The precision of a phase-measuring interferometer system can be determined by taking two measurements, subtracting them, and looking at the root-meansquare of the difference wavefront. The chapter discusses the simulation results. The elimination of the errors that reduce the measurement accuracy depends on the type of measurement being performed. Phase-measurement interferometry (PMI) can be applied to any two-beam interferometer, including holographic interferometers. Applications can be divided into: surface figure, surface roughness, and metrology.

1,340 citations

Journal ArticleDOI
TL;DR: The high resolution surface profile of a 3-D diffuse object is obtained by measurement of the phase distribution across the image of a projected sinusoidal grating deformed by the surface, based on phase-shifting interferometric techniques.
Abstract: The high resolution surface profile of a 3-D diffuse object is obtained by measurement of the phase distribution across the image of a projected sinusoidal grating deformed by the surface. A shearing polarization interferometer is used for projection. Deformed grating images are detected by an array camera and processed by a microcomputer. Surface height resolutions of better than 10 μm have been attained, limited essentially by electronic quantization noise. In contrast to direct deformed grating analysis, this method, based on phase-shifting interferometric techniques, is capable of accurate measurement even with coarse projected gratings and low density image sensing arrays. Areas of application include industrial quality control, biostereometrics, robotics, and solid modeling for computer graphics.

990 citations

Journal ArticleDOI
TL;DR: La difference de phase entre les 2 faisceaux interferant varie de maniere connue et on fait des mesures de the distribution d'intensite a travers la pupille correspondant a au moins 3 dephasages differents.
Abstract: La difference de phase entre les 2 faisceaux interferant varie de maniere connue et on fait des mesures de la distribution d'intensite a travers la pupille correspondant a au moins 3 dephasages differents

979 citations

Journal ArticleDOI
TL;DR: To study the occurrence of wave-front irregularities caused by dust particles a model has been developed and countermeasures derived which assure sufficient regularity of contour line plots, and the repeatability of the present experimental setup was better than λ/200 within the 3σ limits.
Abstract: Digital wave-front measuring interferometry is a well-established technique but only few investigations of systematic error sources have been carried out so far. In this work three especially serious error sources are discussed in some detail: inaccuracies of the reference phase values needed for this type of evaluation technique; disturbances due to extraneous fringes; and spatially high frequency noise on the wave fronts caused by dust particles, inhomogeneities, etc. For the first two error sources formulas of the resulting phase deviation are derived and compensation possibilities discussed and experimentally verified. To study the occurrence of wave-front irregularities caused by dust particles a model has been developed and countermeasures derived which assure sufficient regularity of contour line plots. The repeatability of the present experimental setup was better than λ/200 within the 3σ limits.

792 citations