scispace - formally typeset
Search or ask a question
Author

Ajit J. Deshmukh

Bio: Ajit J. Deshmukh is an academic researcher from New York University. The author has contributed to research in topics: Arthroplasty & Harris Hip Score. The author has an hindex of 17, co-authored 51 publications receiving 925 citations. Previous affiliations of Ajit J. Deshmukh include Lenox Hill Hospital & Hospital for Special Surgery.


Papers
More filters
Journal ArticleDOI
TL;DR: Very modest functional advantages early in recovery after direct anterior THA compared to posterior-approach THA are observed, and these findings may not generalize well to lower-volume practice settings or to surgeons earlier in the learning curve of direct anterior ThA.
Abstract: Background Newer surgical approaches to THA, such as the direct anterior approach, may influence a patient’s time to recovery, but it is important to make sure that these approaches do not compromise reconstructive safety or accuracy.

190 citations

Journal ArticleDOI
TL;DR: Use of fluoroscopy with the patient in the supine position during direct anterior THA enables intraoperative assessment of cup orientation resulting in decreased variability of acetabular cup anteversion, but there is a learning curve associated with achieving this accuracy.
Abstract: Background The direct anterior approach for THA offers some advantages, but is associated with a significant learning curve. Some of the technical difficulties can be addressed by the use of intraoperative fluoroscopy which may improve the accuracy of acetabular component placement.

124 citations

Journal ArticleDOI
TL;DR: In this paper, the authors compared gait parameters prior to, at 6 months and 1 year following total hip arthroplasty (THA) performed via direct anterior approach (DAA) and posterior approach (PA) by a single surgeon in 22 patients.
Abstract: We compared gait parameters prior to, at 6 months and 1 year following total hip arthroplasty (THA) performed via direct anterior approach (DAA) and posterior approach (PA) by a single surgeon in 22 patients. A gait analysis system involving reflective markers, infrared cameras and a multicomponent force plate was utilized. Postoperatively, the study cohort demonstrated improvement in flexion/extension range of motion (ROM) (P = 0.001), peak flexion (P = 0.005) and extension (P = 0.002) moments with no differences between groups. Internal/external ROM improved significantly in the DAA group (P = 0.04) with no change in the PA group. THA performed via DAA and PA offers similar improvement in gait parameters with the exception of internal/external ROM which might be related to the release and repair of external rotators during PA THA.

68 citations

Journal ArticleDOI
TL;DR: TKA improves knee adduction moment at 6 months, but this effect is lost with time (1 year), and there is a correlation between the increase in dynamic varus angle and increase in adduction moments from the 6-month to 1 year followups.
Abstract: Background Dynamic knee varus angle and adduction moments have been reported to be reduced after TKA. However, it is unclear whether this reduction is maintained long term.

63 citations

Journal ArticleDOI
TL;DR: Rotating hinge knee prostheses are most commonly indicated for infection, aseptic loosening, instability and bone loss in the literature, but continue to have high complication and revision rates.
Abstract: Introduction The rotating hinge prosthesis was originally used and designed as a primary total knee arthroplasty implant, but was hampered due to poor outcomes and catastrophic failures. Newer rotating hinge implants can be utilized in complex revision total knee arthroplasties when appropriately indicated, but their outcome data is very difficult to interpret due to the strict and varied indications for use and subsequently small number of procedures performed. The goal of this review is to evaluate the current evidence on large cohort, rotating hinge knee prostheses used in the revision setting, in order to provide a clearer understanding of the indications, outcomes and complications. Methods The PubMed database was utilized to search the available literature regarding “hinged knee,” or “rotating hinge” devices. Exclusion criteria included papers focusing on primary arthroplasty, revision for oncologic issues, one-stage revision for infection or studies with less than fifty cases. Results Review of 115 abstracts after initial search, led to ten studies in the literature that met our inclusion and exclusion criteria. The data shows that rotating hinge knee implants have good survivorship ranging from 51% to 92.5% at 10 years post-operatively. Complication rates range from 9.2% to 63% with infection and aseptic loosening as the most common complications. Conclusion Rotating hinge knee prostheses are most commonly indicated for infection, aseptic loosening, instability and bone loss in the literature. They have good outcome scores and survivorship, but continue to have high complication and revision rates. The implant is a good option when utilized appropriately for patients that are not candidates for less constrained devices.

58 citations


Cited by
More filters
01 Jan 2012
TL;DR: Compared with usual care, bariatric surgery was associated with reduced number of cardiovascular deaths and lower incidence of cardiovascular events in obese adults.
Abstract: Context Obesity is a risk factor for cardiovascular events. Weight loss might protect against cardiovascular events, but solid evidence is lacking. Objective To study the association between bariatric surgery, weight loss, and cardiovascular events. Design, Setting, and Participants The Swedish Obese Subjects (SOS) study is an ongoing, nonrandomized, prospective, controlled study conducted at 25 public surgical departments and 480 primary health care centers in Sweden of 2010 obese participants who underwent bariatric surgery and 2037 contemporaneously matched obese controls who received usual care. Patients were recruited between September 1, 1987, and January 31, 2001. Date of analysis was December 31, 2009, with median follow-up of 14.7 years (range, 0-20 years). Inclusion criteria were age 37 to 60 years and a body mass index of at least 34 in men and at least 38 in women. Exclusion criteria were identical in surgery and control patients. Surgery patients underwent gastric bypass (13.2%), banding (18.7%), or vertical banded gastroplasty (68.1%), and controls received usual care in the Swedish primary health care system. Physical and biochemical examinations and database cross-checks were undertaken at preplanned intervals. Main Outcome Measures The primary end point of the SOS study (total mortality) was published in 2007. Myocardial infarction and stroke were predefined secondary end points, considered separately and combined. Results Bariatric surgery was associated with a reduced number of cardiovascular deaths (28 events among 2010 patients in the surgery group vs 49 events among 2037 patients in the control group; adjusted hazard ratio [HR], 0.47; 95% CI, 0.29-0.76; P = .002). The number of total first time (fatal or nonfatal) cardiovascular events (myocardial infarction or stroke, whichever came first) was lower in the surgery group (199 events among 2010 patients) than in the control group (234 events among 2037 patients; adjusted HR, 0.67; 95% CI, 0.54-0.83; P Conclusion Compared with usual care, bariatric surgery was associated with reduced number of cardiovascular deaths and lower incidence of cardiovascular events in obese adults.

1,117 citations

Journal ArticleDOI
TL;DR: The research suggests that there are several advantages to 3D-printed applications, but that further research is needed to determine whether the increased intervention costs can be balanced with the observable advantages of this new technology.
Abstract: Three-dimensional (3D) printing has numerous applications and has gained much interest in the medical world. The constantly improving quality of 3D-printing applications has contributed to their increased use on patients. This paper summarizes the literature on surgical 3D-printing applications used on patients, with a focus on reported clinical and economic outcomes. Three major literature databases were screened for case series (more than three cases described in the same study) and trials of surgical applications of 3D printing in humans. 227 surgical papers were analyzed and summarized using an evidence table. The papers described the use of 3D printing for surgical guides, anatomical models, and custom implants. 3D printing is used in multiple surgical domains, such as orthopedics, maxillofacial surgery, cranial surgery, and spinal surgery. In general, the advantages of 3D-printed parts are said to include reduced surgical time, improved medical outcome, and decreased radiation exposure. The costs of printing and additional scans generally increase the overall cost of the procedure. 3D printing is well integrated in surgical practice and research. Applications vary from anatomical models mainly intended for surgical planning to surgical guides and implants. Our research suggests that there are several advantages to 3D-printed applications, but that further research is needed to determine whether the increased intervention costs can be balanced with the observable advantages of this new technology. There is a need for a formal cost–effectiveness analysis.

698 citations

Journal ArticleDOI
TL;DR: A model of budget impact, in the perspective of the Italian NHS, is built from the data related to cases of major surgical orthopedic procedures and a meta-analysis on the pivotal RCT, which aims to measure the differential effects in terms of prevention of VTE, showing that the financial impact of the NOA in the prophylaxis of major Orthopedic surgery is not particularly relevant.
Abstract: Venous thromboembolism (VTE) is defined as the obstruction, partial or complete, of one or more veins of deep circulation. It is a condition that can lead to a deterioration in his state of health until death, manifesting as deep vein thrombosis (DVT) or pulmonary embolism (PE). The major orthopedic surgery and the surgical oncology are frequently associated with thromboembolic complications, because of conditions that are often critical in these patients. It is estimated that in Italy DVT has an incidence that varies between 50 and 150 new cases per 100,000 population, while the prevalence would be between 2.5 and 5%. In the absence of thromboprophylaxis, the orthopedic surgery lead to a high increased risk of VTE. In elective hip replacement, in the absence of prophylaxis, the incidence of DVT and of fatal PE is about 50% and 2% respectively. In elective knee arthroplasty the risk of venous thromboembolic complications is even higher. It is estimated that 56.2% of the costs of prophylaxis with Low Molecular Weight Heparin (LMWH) in patients undergoing major orthopedic surgery are attributable to the cost of drugs (about € 200), followed (with 44.8%) by the cost of administration (approximately € 159). The average total cost/day was estimated at € 8 per patient. In Italy, it has been estimated an annual cost for new cases between 215 and 260 million €. The clinical advantages of the New Oral Anticoagulants (NOA) appear to be substantially clear, the major concern with regard to their reimbursement is therefore linked to the financial impact, due to the higher cost per day of the NOA compared with LMWH. To this end, it was built a model of budget impact, in the perspective of the Italian NHS, from the data related to cases of major surgical orthopedic procedures and a meta-analysis on the pivotal RCT, which aims to measure the differential effects in terms of prevention of VTE. The results show that the financial impact of the NOA in the prophylaxis of major orthopedic surgery is not particularly relevant. In fact, the major pharmaceutical costs that, at national level, amount to € 10.8 mil. (€ 15.2 mil. in the case of prolonged prophylaxis in knee operations) would be more than offset by savings in terms of fewer treatments of VTE, which is based on the assumption of more than 4,000 cases, up to about 6,600 in hypothesis best efficacy.

507 citations

Journal ArticleDOI
TL;DR: The defensin system may operate in conjunction with or independently from oxygen-dependent microbicidal processes to enable human neutrophils to inactivate and destroy potential pathogens.
Abstract: We extracted a granule-rich sediment from normal human neutrophils and subjected it to chromatographic, electrophoretic, and functional analysis. The extract contained three small (molecular weight less than 3,500) antibiotic peptides that were named human neutrophil peptide (HNP)-1, HNP-2, and HNP-3, and which will be referred to as "defensins." HNP 1-3, a mixture of the three defensins, killed Staphylococcus aureus, Pseudomonas aeruginosa, and Escherichia coli effectively in vitro when tested in 10 mM phosphate buffer containing certain nutrients, but it had little or no bactericidal activity in nutrient-free buffer. In contrast, the nutrient-free buffer supported a high degree of activity by HNP 1-3 against Cryptococcus neoformans. In addition to its antibacterial and antifungal properties, HNP 1-3 directly inactivated herpes simplex virus, Type 1. Two of the individual purified defensins, HNP-1 and HNP-2, were as microbicidal as the mixture HNP 1-3. HNP-3 was less active than the other defensins against most but not all of the microbes tested. Immunoperoxidase stains revealed HNP 1-3 to have a granular localization in the neutrophil's cytoplasm by light microscopy. Frozen thin section immunogold transmission electron microscopy showed HNP 1-3 to be localized in azurophil granules. These studies define a broad-spectrum antimicrobial system in human neutrophils. The defensin system may operate in conjunction with or independently from oxygen-dependent microbicidal processes to enable human neutrophils to inactivate and destroy potential pathogens.

468 citations

Journal Article
TL;DR: In this paper, a series of 437 consecutive, unselected patients who had 494 primary total hip arthroplasty surgeries done through an anterior approach on an orthopaedic table from September 1996 to September 2004 was reviewed.
Abstract: Dislocation remains the leading early complication of total hip arthroplasty; surgical approach and implant positioning have been recognized as factors influencing total hip arthroplasty stability. We describe a total hip arthroplasty technique done through a single, tissue sparing anterior approach that allows implantation of the femoral and acetabular components without detaching or sectioning any of the muscles and tendons around the hip joint. A series of 437 consecutive, unselected patients who had 494 primary total hip arthroplasty surgeries done through an anterior approach on an orthopaedic table from September 1996 to September 2004 was reviewed. There were 54 hybrid and 442 uncemented hips in the 437 patients (57 bilateral). The average patient age was 64 years. Radiographic analysis showed an average abduction angle of 42°, with 96% in the range of 35° to 50° abduction. The average cup anteversion was 19° with 93% within the target range of 10° to 25°. Postoperative leg length discrepancy averaged 3 ± 2 mm (range, 0-26 mm). Three patients sustained dislocations for an overall dislocation rate of 0.61%, and no patients required revision surgery for recurrent dislocation. There were 17 operative complications, including one deep infection, three wound infections, one transient femoral nerve palsy, three greater trochanter fracture, two femoral shaft fractures four calcar fractures, and three ankle fractures. Operative time averaged 75 minutes (range 40-150 minutes), and the average blood loss was 350 mL (range, 100-1300 mL). The mean hospital stay was 3 days (range, 1-17 days). The anterior approach on the orthopaedic table is a minimally invasive technique applicable to all primary hip patients. This technique allows accurate and reproducible component positioning and leg-length restoration and does not increase the rate of hip dislocation.

457 citations