Alberto Martegani

Bio: Alberto Martegani is an academic researcher. The author has contributed to research in topics: Contrast-enhanced ultrasound & Ultrasound. The author has an hindex of 13, co-authored 17 publications receiving 1848 citations.

Papers
More filters
Journal ArticleDOI
01 Feb 2008
TL;DR: EFSUMB study group M. Claudon, D. Cosgrove, T. Tranquart, L. Thorelius, and H. Whittingham study group L. de.
Abstract: EFSUMB study group M. Claudon1, D. Cosgrove2, T. Albrecht3, L. Bolondi4, M. Bosio5, F. Calliada6, J.-M. Correas7, K. Darge8, C. Dietrich9, M. D'On ofrio10, D. H. Evans11, C. Filice12, L. Greiner13, K. Jäger14, N. de. Jong15, E. Leen16, R. Lencioni17, D. Lindsell18, A. Martegani19, S. Meairs20, C. Nolsøe21, F. Piscaglia22, P. Ricci23, G. Seidel24, B. Skjoldbye25, L. Solbiati26, L. Thorelius27, F. Tranquart28, H. P. Weskott29, T. Whittingham30

755 citations

Journal ArticleDOI
TL;DR: There is no guidance document providing a description of essential technical requirements, proposed investigator qualifications, suggested investigational procedures and steps, guidance on image interpretation, recommended and established clinical indications and safety considerations.
Abstract: specific imaging techniques, are increasingly accepted in clinical use for diagnostic imaging and post-interventional workup in several organs. Presently, there is no guidance document providing a description of essential technical requirements, proposed investigator qualifications, suggested investigational procedures and steps, guidance on image interpretation, recommended and established clinical indications and safety considerations.

429 citations

Journal ArticleDOI
TL;DR: This study is the first large-scale implementation of i CEUS in neurosurgery as a dynamic and continuous real-time imaging tool for brain surgery and provides the first iCEUS characterization of different brain neoplasms.
Abstract: Background Contrast-enhanced ultrasound (CEUS) is a dynamic and continuous modality that offers a real-time, direct view of vascularization patterns and tissue resistance for many organs. Thanks to newer ultrasound contrast agents, CEUS has become a well-established, live-imaging technique in many contexts, but it has never been used extensively for brain imaging. The use of intraoperative CEUS (iCEUS) imaging in neurosurgery is limited. Objective To provide the first dynamic and continuous iCEUS evaluation of a variety of brain lesions. Methods We evaluated 71 patients undergoing iCEUS imaging in an off-label setting while being operated on for different brain lesions; iCEUS imaging was obtained before resecting each lesion, after intravenous injection of ultrasound contrast agent. A semiquantitative, offline interobserver analysis was performed to visualize each brain lesion and to characterize its perfusion features, correlated with histopathology. Results In all cases, the brain lesion was visualized intraoperatively with iCEUS. The afferent and efferent blood vessels were identified, allowing evaluation of the time and features of the arterial and venous phases and facilitating the surgical strategy. iCEUS also proved to be useful in highlighting the lesion compared with standard B-mode imaging and showing its perfusion patterns. No adverse effects were observed. Conclusion Our study is the first large-scale implementation of iCEUS in neurosurgery as a dynamic and continuous real-time imaging tool for brain surgery and provides the first iCEUS characterization of different brain neoplasms. The ability of CEUS to highlight and characterize brain tumor will possibly provide the neurosurgeon with important information anytime during a surgical procedure.

148 citations

Journal ArticleDOI
TL;DR: The ability of CEUS to distinguish between tumor and artifacts or normal brain on B-mode is based on its capacity to show the vascularization degree and not the echogenicity of the tissues, therefore CEUS can play a decisive role in the process of maximizing GBM resection.
Abstract: OBJECTIVE The purpose of this study was to assess the capability of contrast-enhanced ultrasound (CEUS) to identify residual tumor mass during glioblastoma multiforme (GBM) surgery, to increase the extent of resection. METHODS The authors prospectively evaluated 10 patients who underwent surgery for GBM removal with navigated ultrasound guidance. Navigated B-mode and CEUS were performed prior to resection, during resection, and after complete tumor resection. Areas suspected for residual tumors on B-mode and CEUS studies were localized within the surgical field with navigated ultrasound and samples were sent separately for histopathological analysis to confirm tumor presence. RESULTS In all cases tumor remnants were visualized as hyperechoic areas on B-mode, highlighted as CEUS-positive areas, and confirmed as tumoral areas on histopathological analysis. In 1 case only, CEUS partially failed to demonstrate residual tumor because the residual hyperechoic area was devascularized prior to ultrasound contrast...

98 citations

Journal ArticleDOI
TL;DR: CEUS is more sensitive than US in the detection of solid organ injury, potentially reducing the need for further imaging and false negatives from CEUS are due to minor injuries, without relevant consequences for patient management and prognosis.
Abstract: The objective of this study was to evaluate the concordance of US and contrast-enhanced US (CEUS) with CT in the assessment of solid organ injury following blunt trauma. Patients underwent complete US examination, including free fluid search and solid organ analysis. CEUS followed, using low-mechanical index techniques and SonoVue. CT was performed within 1 h. Among 156 enrolled patients, 91 had one or more abnormalities (n = 107) at CT: 26 renal, 38 liver, 43 spleen. Sensitivity, specificity, and accuracy for renal trauma at baseline US were 36%, 98%, and 88%, respectively, after CEUS values increased to 69%, 99%, and 94%. For liver baseline US values were 68%, 97%, and 90%; after CEUS were 84%, 99%, and 96%. For spleen, results were 77%, 96%, and 91% at baseline US and 93%, 99%, and 97% after CEUS. Per patient evaluation gave the following results in terms of sensitivity, specificity and accuracy: 79%, 82%, 80% at baseline US; 94%, 89%, and 92% following CEUS. CEUS is more sensitive than US in the detection of solid organ injury, potentially reducing the need for further imaging. False negatives from CEUS are due to minor injuries, without relevant consequences for patient management and prognosis.

92 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: These liver CEUS guidelines and recommendations are intended to create standard protocols for the use and administration of UCA in liver applications on an international basis and improve the management of patients worldwide.
Abstract: Initially, a set of guidelines for the use of ultrasound contrast agents was published in 2004 dealing only with liver applications. A second edition of the guidelines in 2008 reflected changes in the available contrast agents and updated the guidelines for the liver, as well as implementing some non-liver applications. Time has moved on, and the need for international guidelines on the use of CEUS in the liver has become apparent. The present document describes the third iteration of recommendations for the hepatic use of contrast enhanced ultrasound (CEUS) using contrast specific imaging techniques. This joint WFUMB-EFSUMB initiative has implicated experts from major leading ultrasound societies worldwide. These liver CEUS guidelines are simultaneously published in the official journals of both organizing federations (i.e., Ultrasound in Medicine and Biology for WFUMB and Ultraschall in der Medizin/European Journal of Ultrasound for EFSUMB). These guidelines and recommendations provide general advice on the use of all currently clinically available ultrasound contrast agents (UCA). They are intended to create standard protocols for the use and administration of UCA in liver applications on an international basis and improve the management of patients worldwide.

1,042 citations

Journal ArticleDOI
TL;DR: Authors F. Piscaglia, C. Nolsøe, M. M. Gilja, and H. P. Weskott review the manuscript and suggest ways in which the manuscript could have been improved.
Abstract: Authors F. Piscaglia1, C. Nolsøe2, C. F. Dietrich3, D. O. Cosgrove4, O. H. Gilja5, M. Bachmann Nielsen6, T. Albrecht7, L. Barozzi8, M. Bertolotto9, O. Catalano10, M. Claudon11, D. A. Clevert12, J. M. Correas13, M. D’Onofrio14, F. M. Drudi15, J. Eyding16, M. Giovannini17, M. Hocke18, A. Ignee19, E. M. Jung20, A. S. Klauser21, N. Lassau22, E. Leen23, G. Mathis24, A. Saftoiu25, G. Seidel26, P. S. Sidhu27, G. ter. Haar28, D. Timmerman29, H. P. Weskott30

975 citations

Journal ArticleDOI
01 Feb 2008
TL;DR: EFSUMB study group M. Claudon, D. Cosgrove, T. Tranquart, L. Thorelius, and H. Whittingham study group L. de.
Abstract: EFSUMB study group M. Claudon1, D. Cosgrove2, T. Albrecht3, L. Bolondi4, M. Bosio5, F. Calliada6, J.-M. Correas7, K. Darge8, C. Dietrich9, M. D'On ofrio10, D. H. Evans11, C. Filice12, L. Greiner13, K. Jäger14, N. de. Jong15, E. Leen16, R. Lencioni17, D. Lindsell18, A. Martegani19, S. Meairs20, C. Nolsøe21, F. Piscaglia22, P. Ricci23, G. Seidel24, B. Skjoldbye25, L. Solbiati26, L. Thorelius27, F. Tranquart28, H. P. Weskott29, T. Whittingham30

755 citations

Journal ArticleDOI
TL;DR: The updated version of the EFSUMB guidelines on the application of non-hepatic contrast-enhanced ultrasound (CEUS) deals with the use of microbubble ultrasound contrast outside the liver in the many established and emerging applications.
Abstract: The updated version of the EFSUMB guidelines on the application of non-hepatic contrast-enhanced ultrasound (CEUS) deals with the use of microbubble ultrasound contrast outside the liver in the many established and emerging applications.

638 citations

Journal ArticleDOI
TL;DR: The present large-scale retrospective analysis showed that SonoVue has a good safety profile in abdominal applications, with an AE reporting rate lower than or similar to that reported for radiologic and magnetic resonance contrast agents.
Abstract: The aim of the present retrospective study was to assess the incidence of adverse events (AE) of a second-generation ultrasound contrast agent in real clinical practice. A total of 28 Italian Centres provided data on the postmarketing use of SonoVue (Bracco Spa, Milan, Italy) in abdominal examination performed between December 2001 and December 2004. A total of 23 188 investigations were reported. No fatal event occurred. AEs were reported in 29 cases, of which only two were graded as serious; the rest, 27, were nonserious (23 mild, three moderate and one severe). The overall reporting rate of serious AE was 0.0086%. Overall, only four AEs required treatment (two serious, two nonserious including one moderate and one severe AEs). In conclusion, the present large-scale retrospective analysis showed that SonoVue has a good safety profile in abdominal applications, with an AE reporting rate lower than or similar to that reported for radiologic and magnetic resonance contrast agents.

632 citations