scispace - formally typeset
Search or ask a question
Author

Alexander J. Yeh

Bio: Alexander J. Yeh is an academic researcher from Stanford University. The author has contributed to research in topics: Wireless power transfer & Transmitter. The author has an hindex of 7, co-authored 20 publications receiving 859 citations.

Papers
More filters
Journal ArticleDOI
TL;DR: It is shown how three adaptations of the implant allow for untethered optogenetic control throughout the nervous system (brain, spinal cord and peripheral nerve endings) of behaving mice.
Abstract: Small, lightweight LED implants and a radio-frequency transducer as a power source enable wireless optogenetic stimulation in the brain, spinal cord and peripheral nervous system of behaving mice.

441 citations

Journal ArticleDOI
TL;DR: A wireless powering method is reported that overcomes the challenge of energy transfer beyond superficial depths in tissue by inducing spatially focused and adaptive electromagnetic energy transport via propagating modes in tissue and is used to power a tiny electrostimulator that is orders of magnitude smaller than conventional pacemakers.
Abstract: The ability to implant electronic systems in the human body has led to many medical advances. Progress in semiconductor technology paved the way for devices at the scale of a millimeter or less (“microimplants”), but the miniaturization of the power source remains challenging. Although wireless powering has been demonstrated, energy transfer beyond superficial depths in tissue has so far been limited by large coils (at least a centimeter in diameter) unsuitable for a microimplant. Here, we show that this limitation can be overcome by a method, termed midfield powering, to create a high-energy density region deep in tissue inside of which the power-harvesting structure can be made extremely small. Unlike conventional near-field (inductively coupled) coils, for which coupling is limited by exponential field decay, a patterned metal plate is used to induce spatially confined and adaptive energy transport through propagating modes in tissue. We use this method to power a microimplant (2 mm, 70 mg) capable of closed-chest wireless control of the heart that is orders of magnitude smaller than conventional pacemakers. With exposure levels below human safety thresholds, milliwatt levels of power can be transferred to a deep-tissue (>5 cm) microimplant for both complex electronic function and physiological stimulation. The approach developed here should enable new generations of implantable systems that can be integrated into the body at minimal cost and risk.

430 citations

Journal ArticleDOI
TL;DR: In this paper, an approach for wirelessly powering implantable stimulators using electromagnetic midfield is presented. But it is not suitable for in vivo optogenetic stimulation, as it requires optical fibers or mounted prosthesis.
Abstract: Conventional methods for in vivo optogenetic stimulation require optical fibers or mounted prosthesis. We present an approach for wirelessly powering implantable stimulators using electromagnetic midfield. By exploiting the properties of the midfield, we demonstrate the ability to generate high intensity light pulses in a freely moving animal.

42 citations

Proceedings ArticleDOI
01 Dec 2012
TL;DR: In this article, a highly sensitive field effect sensor with an extended gate ISFET was proposed, achieving a remarkable sensitivity of 130mV/pH, exceeding the conventional Nernst limit of 59mV /pH.
Abstract: A highly sensitive field-effect sensor immune to environmental potential fluctuation is proposed. The sensor circuit consists of two sensors each with a charge sensing field effect transistor (FET) and an extended sensing gate (SG). By enlarging the sensing gate of an extended gate ISFET, a remarkable sensitivity of 130mV/pH is achieved, exceeding the conventional Nernst limit of 59mV/pH. The proposed differential sensing circuit consists of a pair of matching n-channel and p-channel ion sensitive sensors connected in parallel and biased at a matched transconductance bias point. Potential fluctuations in the electrolyte appear as common mode signal to the differential pair and are cancelled by the matched transistors. This novel differential measurement technique eliminates the need for a true reference electrode such as the bulky Ag/AgCl reference electrode and enables the use of the sensor for autonomous and implantable applications.

34 citations

Patent
Ada S. Y. Poon1, Alexander J. Yeh1, Yuji Tanabe1, John S. Ho1, Sanghoek Kim1 
16 Sep 2014
TL;DR: In this paper, the authors describe implantable devices/sensors that can be implanted at target locations in a patient, to stimulate areas such as the heart, brain, spinal cord, or muscle tissue, and/or to sense biological, physiological, chemical attributes of the blood, tissue and other patient parameters.
Abstract: Implantable devices and/or sensors can be wirelessly powered by controlling and propagating electromagnetic waves in a patient's tissue. Such implantable devices/sensors can be implanted at target locations in a patient, to stimulate areas such as the heart, brain, spinal cord, or muscle tissue, and/or to sense biological, physiological, chemical attributes of the blood, tissue, and other patient parameters. The propagating electromagnetic waves can be generated with sub-wavelength structures configured to manipulate evanescent fields outside of tissue to generate the propagating waves inside the tissue. Methods of use are also described.

23 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: This Review will cover materials and devices designed for mimicking the skin's ability to sense and generate biomimetic signals.
Abstract: Skin plays an important role in mediating our interactions with the world. Recreating the properties of skin using electronic devices could have profound implications for prosthetics and medicine. The pursuit of artificial skin has inspired innovations in materials to imitate skin's unique characteristics, including mechanical durability and stretchability, biodegradability, and the ability to measure a diversity of complex sensations over large areas. New materials and fabrication strategies are being developed to make mechanically compliant and multifunctional skin-like electronics, and improve brain/machine interfaces that enable transmission of the skin's signals into the body. This Review will cover materials and devices designed for mimicking the skin's ability to sense and generate biomimetic signals.

1,681 citations

Journal ArticleDOI
01 Sep 2018-Nature
TL;DR: Self-powered ultra-flexible electronic devices that can measure biometric signals with very high signal-to-noise ratios when applied to skin or other tissue are realized and offer a general platform for next-generation self-powered electronics.
Abstract: Next-generation biomedical devices1-9 will need to be self-powered and conformable to human skin or other tissue. Such devices would enable the accurate and continuous detection of physiological signals without the need for an external power supply or bulky connecting wires. Self-powering functionality could be provided by flexible photovoltaics that can adhere to moveable and complex three-dimensional biological tissues1-4 and skin5-9. Ultra-flexible organic power sources10-13 that can be wrapped around an object have proven mechanical and thermal stability in long-term operation13, making them potentially useful in human-compatible electronics. However, the integration of these power sources with functional electric devices including sensors has not yet been demonstrated because of their unstable output power under mechanical deformation and angular change. Also, it will be necessary to minimize high-temperature and energy-intensive processes10,12 when fabricating an integrated power source and sensor, because such processes can damage the active material of the functional device and deform the few-micrometre-thick polymeric substrates. Here we realize self-powered ultra-flexible electronic devices that can measure biometric signals with very high signal-to-noise ratios when applied to skin or other tissue. We integrated organic electrochemical transistors used as sensors with organic photovoltaic power sources on a one-micrometre-thick ultra-flexible substrate. A high-throughput room-temperature moulding process was used to form nano-grating morphologies (with a periodicity of 760 nanometres) on the charge transporting layers. This substantially increased the efficiency of the organophotovoltaics, giving a high power-conversion efficiency that reached 10.5 per cent and resulted in a high power-per-weight value of 11.46 watts per gram. The organic electrochemical transistors exhibited a transconductance of 0.8 millisiemens and fast responsivity above one kilohertz under physiological conditions, which resulted in a maximum signal-to-noise ratio of 40.02 decibels for cardiac signal detection. Our findings offer a general platform for next-generation self-powered electronics.

617 citations

Journal ArticleDOI
TL;DR: The power of this technology by modulating peripheral and spinal pain circuitry is demonstrated, providing evidence for the potential widespread use of these devices in research and future clinical applications of optogenetics outside the brain.
Abstract: Optogenetics allows rapid, temporally specific control of neuronal activity by targeted expression and activation of light-sensitive proteins. Implementation typically requires remote light sources and fiber-optic delivery schemes that impose considerable physical constraints on natural behaviors. In this report we bypass these limitations using technologies that combine thin, mechanically soft neural interfaces with fully implantable, stretchable wireless radio power and control systems. The resulting devices achieve optogenetic modulation of the spinal cord and peripheral nervous system. This is demonstrated with two form factors; stretchable film appliques that interface directly with peripheral nerves, and flexible filaments that insert into the narrow confines of the spinal epidural space. These soft, thin devices are minimally invasive, and histological tests suggest they can be used in chronic studies. We demonstrate the power of this technology by modulating peripheral and spinal pain circuitry, providing evidence for the potential widespread use of these devices in research and future clinical applications of optogenetics outside the brain.

613 citations

Journal ArticleDOI
TL;DR: An integrated approach now supports optogenetic identification of the native, necessary and sufficient causal underpinnings of physiology and behaviour on acute or chronic timescales and across cellular, circuit-level or brain-wide spatial scales.
Abstract: Modern optogenetics can be tuned to evoke activity that corresponds to naturally occurring local or global activity in timing, magnitude or individual-cell patterning. This outcome has been facilitated not only by the development of core features of optogenetics over the past 10 years (microbial-opsin variants, opsin-targeting strategies and light-targeting devices) but also by the recent integration of optogenetics with complementary technologies, spanning electrophysiology, activity imaging and anatomical methods for structural and molecular analysis. This integrated approach now supports optogenetic identification of the native, necessary and sufficient causal underpinnings of physiology and behaviour on acute or chronic timescales and across cellular, circuit-level or brain-wide spatial scales.

512 citations

Journal ArticleDOI
TL;DR: A battery-free implantable pressure sensor made entirely of biodegradable materials and based on fringe-field capacitor technology can wirelessly measure arterial blood flow in live rats and may be advantageous in real-time post-operative monitoring of blood flow after reconstructive surgery.
Abstract: The ability to monitor blood flow is critical to patient recovery and patient outcomes after complex reconstructive surgeries. Clinically available wired implantable monitoring technology requires careful fixation for accurate detection and needs to be removed after use. Here, we report the design of a pressure sensor, made entirely of biodegradable materials and based on fringe-field capacitor technology, for measuring arterial blood flow in both contact and non-contact modes. The sensor is operated wirelessly through inductive coupling, has minimal hysteresis, fast response times, excellent cycling stability, is highly robust, allows for easy mounting and eliminates the need for removal, thus reducing the risk of vessel trauma. We demonstrate the operation of the sensor with a custom-made artificial artery model and in vivo in rats. This technology may be advantageous in real-time post-operative monitoring of blood flow after reconstructive surgery.

495 citations