scispace - formally typeset
Search or ask a question
Author

Andreas Manz

Other affiliations: Bayer, University of Vienna, Technical University of Dortmund  ...read more
Bio: Andreas Manz is an academic researcher from Imperial College London. The author has contributed to research in topics: Capillary electrophoresis & Surface micromachining. The author has an hindex of 64, co-authored 170 publications receiving 24589 citations. Previous affiliations of Andreas Manz include Bayer & University of Vienna.


Papers
More filters
Journal ArticleDOI
Andreas Manz1, N. Graber1, H.M. Widmer1
TL;DR: In this paper, a modular construction of a miniaturized "total chemical analysis system" is proposed, and theoretical performances of such systems based on flow injection analysis, chromatography and electrophoresis are compared with those of existing chemical sensors and analysis systems.
Abstract: Following the trend towards smaller channel inner diameter for better separation performance and shorter channel length for shorter transport time, a modular construction of a miniaturized 'total chemical analysis system' is proposed. The theoretical performances of such systems based on flow injection analysis, chromatography and electrophoresis, are compared with those of existing chemical sensors and analysis systems.

3,017 citations

Journal ArticleDOI
TL;DR: In this article, the authors present a review of the book.http://www.reviewreviews.com/reviews/book-reviews-of-the-book
Abstract: Review

2,157 citations

Journal ArticleDOI
13 Aug 1993-Science
TL;DR: In this article, the authors demonstrated a miniaturized system for sample handling and separation using electrophoresis-based separations of amino acids with up to 75,000 theoretical plates in about 15 seconds.
Abstract: Micromachining technology was used to prepare chemical analysis systems on glass chips (1 centimeter by 2 centimeters or larger) that utilize electroosmotic pumping to drive fluid flow and electrophoretic separation to distinguish sample components. Capillaries 1 to 10 centimeters long etched in the glass (cross section, 10 micrometers by 30 micrometers) allow for capillary electrophoresis-based separations of amino acids with up to 75,000 theoretical plates in about 15 seconds, and separations of about 600 plates can be effected within 4 seconds. Sample treatment steps within a manifold of intersecting capillaries were demonstrated for a simple sample dilution process. Manipulation of the applied voltages controlled the directions of fluid flow within the manifold. The principles demonstrated in this study can be used to develop a miniaturized system for sample handling and separation with no moving parts.

1,815 citations

Journal ArticleDOI
TL;DR: This second part of the review of microfluidic system preparation will cover a number of standard operations as well as some biological applications of micro total analysis systems.
Abstract: After having reviewed some aspects of microfluidic system preparation in the first part (1), in this second part of the review we will cover a number of standard operations (namely: sample preparation, sample injection, sample manipulation, reaction, separation, and detection) as well as some biological applications of micro total analysis systems (namely: cell culture, polymerase chain reaction, DNA separation, DNA sequencing, and clinical diagnostics). As previously, we will include papers issued from different scientific journals as well as useful abstracts from three conference proceedings: MEMS, Transducers, and μTAS. In this second part, we do not include the period covered by the history section (1975-1997) from part 1 but try to cover the relevant examples of the literature published between January 1998 and March 2002. We briefly describe articles that struck us as needing special attention, while more “standard” papers are dutifully reported in groups of interest. An article might be included in more than one section, depending on the ideas developed in it.

1,541 citations

Journal ArticleDOI
15 May 1998-Science
TL;DR: A micromachined chemical amplifier was successfully used to perform the polymerase chain reaction (PCR) in continuous flow at high speed.
Abstract: A micromachined chemical amplifier was successfully used to perform the polymerase chain reaction (PCR) in continuous flow at high speed. The device is analogous to an electronic amplifier and relies on the movement of sample through thermostated temperature zones on a glass microchip. Input and output of material (DNA) is continuous, and amplification is independent of input concentration. A 20-cycle PCR amplification of a 176-base pair fragment from the DNA gyrase gene of Neisseria gonorrhoeae was performed at various flow rates, resulting in total reaction times of 90 seconds to 18.7 minutes.

1,426 citations


Cited by
More filters
Journal ArticleDOI
27 Jul 2006-Nature
TL;DR: The manipulation of fluids in channels with dimensions of tens of micrometres — microfluidics — has emerged as a distinct new field that has the potential to influence subject areas from chemical synthesis and biological analysis to optics and information technology.
Abstract: The manipulation of fluids in channels with dimensions of tens of micrometres--microfluidics--has emerged as a distinct new field. Microfluidics has the potential to influence subject areas from chemical synthesis and biological analysis to optics and information technology. But the field is still at an early stage of development. Even as the basic science and technological demonstrations develop, other problems must be addressed: choosing and focusing on initial applications, and developing strategies to complete the cycle of development, including commercialization. The solutions to these problems will require imagination and ingenuity.

8,260 citations

Journal ArticleDOI
TL;DR: A procedure that makes it possible to design and fabricate microfluidic systems in an elastomeric material poly(dimethylsiloxane) (PDMS) in less than 24 h by fabricating a miniaturized capillary electrophoresis system is described.
Abstract: This paper describes a procedure that makes it possible to design and fabricate (including sealing) microfluidic systems in an elastomeric materialpoly(dimethylsiloxane) (PDMS)in less than 24 h. A network of microfluidic channels (with width >20 μm) is designed in a CAD program. This design is converted into a transparency by a high-resolution printer; this transparency is used as a mask in photolithography to create a master in positive relief photoresist. PDMS cast against the master yields a polymeric replica containing a network of channels. The surface of this replica, and that of a flat slab of PDMS, are oxidized in an oxygen plasma. These oxidized surfaces seal tightly and irreversibly when brought into conformal contact. Oxidized PDMS also seals irreversibly to other materials used in microfluidic systems, such as glass, silicon, silicon oxide, and oxidized polystyrene; a number of substrates for devices are, therefore, practical options. Oxidation of the PDMS has the additional advantage that it ...

5,491 citations

Journal ArticleDOI
07 Apr 2000-Science
TL;DR: An extension to the soft lithography paradigm, multilayersoft lithography, with which devices consisting of multiple layers may be fabricated from soft materials is described, to build active microfluidic systems containing on-off valves, switching valves, and pumps entirely out of elastomer.
Abstract: Soft lithography is an alternative to silicon-based micromachining that uses replica molding of nontraditional elastomeric materials to fabricate stamps and microfluidic channels. We describe here an extension to the soft lithography paradigm, multilayer soft lithography, with which devices consisting of multiple layers may be fabricated from soft materials. We used this technique to build active microfluidic systems containing on-off valves, switching valves, and pumps entirely out of elastomer. The softness of these materials allows the device areas to be reduced by more than two orders of magnitude compared with silicon-based devices. The other advantages of soft lithography, such as rapid prototyping, ease of fabrication, and biocompatibility, are retained.

4,218 citations

Journal ArticleDOI
TL;DR: A review of the physics of small volumes (nanoliters) of fluids is presented, as parametrized by a series of dimensionless numbers expressing the relative importance of various physical phenomena as mentioned in this paper.
Abstract: Microfabricated integrated circuits revolutionized computation by vastly reducing the space, labor, and time required for calculations. Microfluidic systems hold similar promise for the large-scale automation of chemistry and biology, suggesting the possibility of numerous experiments performed rapidly and in parallel, while consuming little reagent. While it is too early to tell whether such a vision will be realized, significant progress has been achieved, and various applications of significant scientific and practical interest have been developed. Here a review of the physics of small volumes (nanoliters) of fluids is presented, as parametrized by a series of dimensionless numbers expressing the relative importance of various physical phenomena. Specifically, this review explores the Reynolds number Re, addressing inertial effects; the Peclet number Pe, which concerns convective and diffusive transport; the capillary number Ca expressing the importance of interfacial tension; the Deborah, Weissenberg, and elasticity numbers De, Wi, and El, describing elastic effects due to deformable microstructural elements like polymers; the Grashof and Rayleigh numbers Gr and Ra, describing density-driven flows; and the Knudsen number, describing the importance of noncontinuum molecular effects. Furthermore, the long-range nature of viscous flows and the small device dimensions inherent in microfluidics mean that the influence of boundaries is typically significant. A variety of strategies have been developed to manipulate fluids by exploiting boundary effects; among these are electrokinetic effects, acoustic streaming, and fluid-structure interactions. The goal is to describe the physics behind the rich variety of fluid phenomena occurring on the nanoliter scale using simple scaling arguments, with the hopes of developing an intuitive sense for this occasionally counterintuitive world.

4,044 citations