scispace - formally typeset
Search or ask a question
Author

Anupama Gupta

Bio: Anupama Gupta is an academic researcher. The author has contributed to research in topics: Light intensity. The author has an hindex of 2, co-authored 2 publications receiving 18 citations.

Papers
More filters
Journal ArticleDOI
TL;DR: The type of obturation may play more important role than the type of instrument or retained/non-retained instrument factor in sealing properties of different obTuration systems placed over apically fractured rotary NiTi files.
Abstract: Aim: To evaluate sealing properties of different obturation systems placed over apically fractured rotary NiTi files. Materials and Methods: Forty freshly extracted human mandibular premolars were prepared by using Protaper (Dentsply-Maillefer, Ballaigues, Switzerland) or the RaCe (FKG Dentaire, La Chaux-de-Fonds, Switzerland) systems (n=20 for each), after which half of the specimens were subjected to instrument separation at the apical level. Roots with and without apically separated instruments (n=5) were filled with the two obturation systems i.e. Thermafil and lateral compaction technique. The modified glucose penetration setup was used to assess the microleakage. The leakage data was statistically analyzed. Results: The amount of leakage was significantly lower in specimens containing fractured instruments, regardless of the obturation method used. Roots obturated with Thermafil displayed significantly less leakage than cold lateral compaction technique, both, in the presence and absence of separated instruments. There was no significant difference among specimens prepared with ProTaper and RaCe when Thermafil obturation was done. But with cold lateral compaction technique, RaCe system showed less leakage as compared to ProTaper system. Conclusion: The type of obturation may play more important role than the type of instrument or retained/non-retained instrument factor.

12 citations

Journal ArticleDOI
TL;DR: Cementation of fibre post with superior light transmitting ability using dual cured resin cement resulted in increased degree of polymerization.
Abstract: Aim: To measure the light transmission through different esthetic posts and to evaluate the degree of polymerization of dual cure resin cement cured through these posts Materials and Methods: The posts were divided into two experimental groups ie Group A (DT Light post); Group B (DT White post) and control ie Group C (metal post), each group having 10 samples Posts of each group were illuminated with curing light and photographs were taken keeping the parameters standardized to evaluate the intensity of light transmission at different levels The degree of polymerization of dual cure resin cement was evaluated using Fourier Transform Infrared spectroscopy The data obtained was subjected to statistical analysis Results: DT Light post showed highest light transmission and degree of polymerization The light intensity decreased from cervical to apical for both esthetic post but the decrease from middle to apical third was insignificant for DT White post group No light transmission was detected in metal post but the degree of polymerization decreased significantly from cervical to middle third Conclusion: Cementation of fibre post with superior light transmitting ability using dual cured resin cement resulted in increased degree of polymerization

11 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: The mean push-out bond strengths were higher for Groups I and III where Variolink II resin cement was used for luting the fiber post, which is based on the total etch adhesive approach, compared with Group I and Group III, which had significantly higher values.
Abstract: Introduction: The concept of using a post for the restoration of teeth has been practiced to restore the endodontically treated tooth. Metallic posts have been commonly used, but their delirious effects have led to the development of fiber-reinforced materials that have overcome the limitations of metallic posts. The use of glass and quartz fibers was proposed as an alternative to the dark color of carbon fiber posts as far as esthetics was concerned. Debonding is the most common failure in fiber-reinforced composite type of posts. This study was aimed to compare the push-out bond strength of a self-adhesive dual-cured luting agent (RelyX U100) with a total etch resin luting agent (Variolink II) used to cement two different FRC posts. Materials and Methods: Eighty human maxillary anterior single-rooted teeth were decoronated, endodontically treated, post space prepared and divided into four groups (n = 20); Group I: D.T. light post (RTD) and Variolink II (Ivoclare vivadent), Group II: D.T. light post (RTD) and RelyX U100 (3M ESPE), Group III: Glassix post (Nordin) and Variolink II (Ivoclare vivadent) and Group IV: Glassix post (Nordin) and RelyX U100 (3M ESPE). Each root was sectioned to get slices of 2 ± 0.05-mm thickness. Push-out tests were performed using a triaxial loading frame. To express bond strength in megapascals (Mpa), load value recorded in Newton (N) was divided by the area of the bonded interface. After testing the push-out strengths, the samples were analyzed under a stereomicroscope. Results: The mean values of the push-out bond strength show that Group I and Group III had significantly higher values than Group II and Group IV. The most common mode of failure observed was adhesive between dentin and luting material and between post and luting material. Conclusions: The mean push-out bond strengths were higher for Groups I and III where Variolink II resin cement was used for luting the fiber post, which is based on the total etch adhesive approach. In most of the samples, failure was observed between cement-dentine interface, followed by post-cement interface, which shows difficulty in bonding between post-cement-dentine interface.

31 citations

Journal ArticleDOI
TL;DR: The restoration of endodontically treated teeth is often required and may represent a challenge as there is no consensus on ideal treatment.
Abstract: The restoration of endodontically treated teeth is often required and may represent a challenge as there is no consensus on ideal treatment. The failure of endodontically treated teeth is usually not a consequence of endodontic treatment, but inadequate restorative therapy or periodontal reasons. Prior to the initiation of endodontic treatment the restorability, occlusal function, periodontal health, biologic width, and crown-to-root ratio need to be assessed. If acceptable, the appropriate technique, material, and type of restoration to restore function need to be considered. Posts are used to provide retention for the core material and to replace missing tooth structure. The residual amount of tooth structure will determine its stability for restoration. The creation of adequate ferrule (approaching 2 mm circumferentially is ideal) minimizes the damaging effects of lateral and rotational forces on the restoration and post.

28 citations

Journal ArticleDOI
TL;DR: Calamus may be a good obturation technique for root canal treatment according to the amount of obturating material observed in Calamus group followed by Thermafil and lateral compaction.
Abstract: Introduction The success of root canal treatment depends upon the proper sealing of root canal system. Improper apical seal leads to the microleakage which can be prevented by proper obturation technique.

21 citations

Journal ArticleDOI
TL;DR: All three types of studied posts can be successfully used to restore badly destructed primary anterior teeth, including composite resin, customized quartz fiber and prefabricated glass fiber.
Abstract: Background: Restoration of anterior primary teeth with severe caries lesion is a big challenge. The aim of this study was to compare the fracture resistance of three types of post, including composite resin, customized quartz fiber and prefabricated glass fiber in restoration of severely damaged primary anterior teeth. Materials and Methods: Sixty extracted human primary maxillary incisors were randomly divided into three groups: Group 1: Customized quartz fiber post, Group 2: Composite post and Group 3: Prefabricated glass fiber post. Due to the effect of bonded area on the fracture resistance, the bonded surface of each sample was measured 1 mm above cementoenamel junction. An increasing force was subjected with a crosshead speed of 0.5 mm/min by a universal testing machine until fracture occurred, and the failure mode was assessed afterwards. Data were analyzed using One-way analysis of variance and Kruskal-Wallis tests. The level of significance was considered at P Results: The mean fracture resistance values of three groups were 343.28 N, 278.70 N and 284.76 N, respectively. Although customized quartz fiber post showed the greatest fracture resistance, statistical analysis revealed no significant difference between groups (P = 0.21). The mean fracture strength values of three groups were 12.82 N/mm–2 , 11.93 N/mm–2 and 11.31 N/mm–2 , respectively; however, the differences were not statistically significant (P = 0.72). Favorable failure mode was more frequent in all groups (P = 0.12). Conclusion: Within the limitations of this study, it can be concluded that all three types of studied posts can be successfully used to restore badly destructed primary anterior teeth.

18 citations