scispace - formally typeset
Search or ask a question
Author

Cecil E. Hayes

Other affiliations: GE Healthcare, General Electric
Bio: Cecil E. Hayes is an academic researcher from University of Washington. The author has contributed to research in topics: Electromagnetic coil & Magnetic resonance imaging. The author has an hindex of 42, co-authored 69 publications receiving 7479 citations. Previous affiliations of Cecil E. Hayes include GE Healthcare & General Electric.


Papers
More filters
Journal ArticleDOI
TL;DR: Methods for simultaneously acquiring and subsequently combining data from a multitude of closely positioned NMR receiving coils are described, conceptually similar to phased array radar and ultrasound and hence the techniques are called the “NMR phased array.”
Abstract: We describe methods for simultaneously acquiring and subsequently combining data from a multitude of closely positioned NMR receiving coils. The approach is conceptually similar to phased array radar and ultrasound and hence we call our techniques the “NMR phased array.” The NMR phased array offers the signal-to-noise ratio (SNR) and resolution of a small surface coil over fields-of-view (FOV) normally associated with body imaging with no increase in imaging time. The NMR phased array can be applied to both imaging and spectroscopy for all pulse sequences. The problematic interactions among nearby surface coils is eliminated (a) by overlapping adjacent coils to give zero mutual inductance, hence zero interaction, and (b) by attaching low input impedance preamplifiers to all coils, thus eliminating interference among next nearest and more distant neighbors. We derive an algorithm for combining the data from the phased array elements to yield an image with optimum SNR. Other techniques which are easier to implement at the cost of lower SNR are explored. Phased array imaging is demonstrated with high resolution (512 × 512, 48-cm FOV, and 32-cm FOV) spin-echo images of the thoracic and lumbar spine. Data were acquired from four-element linear spine arrays, the first made of 12-cm square coils and the second made of 8-cm square coils. When compared with images from a single 15 × 30-cm rectangular coil and identical imaging parameters, the phased array yields a 2X and 3X higher SNR at the depth of the spine ( ∼ 7 cm). © 1990 Academic Press, Inc.

2,360 citations

Journal ArticleDOI
TL;DR: Optimisation de lhomogeneite du champ radiofrequence necessaire pour produire des sequences d'impulsions a multichocs and du rapport signal sur bruit.

786 citations

Journal ArticleDOI
TL;DR: In this article, a comparison of experimental imaging results obtained with linearly polarized and circularly polarized radiofrequency excitation and reception is presented, and the expected benefits of circular polarization over linear polarization in reduction of excitation power (up to 50% reduction) and signal-to-noise advantage (√ 2) have been realized in practice with cylindrical objects and human subjects.

271 citations

Patent
05 Dec 1988
TL;DR: In this article, a method for simultaneously receiving a different NMR response signal from each of a plurality of closely-spaced surface coils, first provides an array of a multiplicity of the surface coils positioned so as to have substantially no interaction with all adjacent surface coils.
Abstract: A method for simultaneously receiving a different NMR response signal from each of a plurality of closely-spaced surface coils, first provides an array of a plurality of the surface coils, each positioned so as to have substantially no interaction with all adjacent surface coils. A different NMR response signal is received from an associated portion of the sample enclosed within an imaging volume defined by the array. Each different NMR response signal is used to construct a different one of a like plurality of NMR images of the sample, with the plurality of different images then being combined, on a point-by-point basis, to produce a single composite NMR image of a total sample portion from which NMR response signal contribution was received by any of the array of surface coils. Interactions between non-adjacent surface coils are minimized by coupling each onto an associated preamplifier.

271 citations

Journal ArticleDOI
TL;DR: Direct nerve imaging can demonstrate nerve continuity, distinguish intraneural from perineural masses, and localize focal nerve compressions prior to surgical exploration, thus avoiding some exploratory surgery and allowing for smaller targeted exposures when surgery is indicated.
Abstract: ✓ Currently, diagnosis and management of disorders involving nerves are generally undertaken without images of the nerves themselves. The authors evaluated whether direct nerve images obtained using the new technique of magnetic resonance (MR) neurography could be used to make clinically important diagnostic distinctions that cannot be readily accomplished using existing methods. The authors obtained T2-weighted fast spin—echo fat-suppressed (chemical shift selection or inversion recovery) and T1-weighted images with planes parallel or transverse to the long axis of nerves using standard or phased-array coils in healthy volunteers and referred patients in 242 sessions. Longitudinal and cross-sectional fascicular images readily distinguished perineural from intraneural masses, thus predicting both resectability and requirement for intraoperative electrophysiological monitoring. Fascicle pattern and longitudinal anatomy firmly identified nerves and thus improved the safety of image-guided procedures. In sev...

237 citations


Cited by
More filters
PatentDOI
TL;DR: The problem of image reconstruction from sensitivity encoded data is formulated in a general fashion and solved for arbitrary coil configurations and k‐space sampling patterns and special attention is given to the currently most practical case, namely, sampling a common Cartesian grid with reduced density.
Abstract: The invention relates to a method of parallel imaging for obtaining images by means of magnetic resonance (MR). The method includes the simultaneous measurement of sets of MR singals by an array of receiver coils, and the reconstruction of individual receiver coil images from the sets of MR signals. In order to reduce the acquisition time, the distance between adjacent phase encoding lines in k-space is increased, compared to standard Fourier imaging, by a non-integer factor smaller than the number of receiver coils. This undersampling gives rise to aliasing artifacts in the individual receiver coil images. An unaliased final image with the same field of view as in standard Fourier imaging is formed from a combination of the individual receiver coil images whereby account is taken of the mutually different spatial sensitivities of the receiver coils at the positions of voxels which in the receiver coil images become superimposed by aliasing. This requires the solution of a linear equation by means of the generalised inverse of a sensitivity matrix. The reduction of the number of phase encoding lines by a non-integer factor compared to standard Fourier imaging provides that different numbers of voxels become superimposed (by aliasing) in different regions of the receiver coil images. This effect can be exploited to shift residual aliasing artifacts outside the area of interest.

6,562 citations

Journal ArticleDOI
TL;DR: This technique, GeneRalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) is an extension of both the PILS and VD‐AUTO‐SMASH reconstruction techniques and provides unaliased images from each component coil prior to image combination.
Abstract: In this study, a novel partially parallel acquisition (PPA) method is presented which can be used to accelerate image acquisition using an RF coil array for spatial encoding. This technique, GeneRalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) is an extension of both the PILS and VD-AUTO-SMASH reconstruction techniques. As in those previous methods, a detailed, highly accurate RF field map is not needed prior to reconstruction in GRAPPA. This information is obtained from several k-space lines which are acquired in addition to the normal image acquisition. As in PILS, the GRAPPA reconstruction algorithm provides unaliased images from each component coil prior to image combination. This results in even higher SNR and better image quality since the steps of image reconstruction and image combination are performed in separate steps. After introducing the GRAPPA technique, primary focus is given to issues related to the practical implementation of GRAPPA, including the reconstruction algorithm as well as analysis of SNR in the resulting images. Finally, in vivo GRAPPA images are shown which demonstrate the utility of the technique.

5,022 citations

Journal ArticleDOI
TL;DR: A novel approach to correcting for intensity nonuniformity in magnetic resonance (MR) data is described that achieves high performance without requiring a model of the tissue classes present, and is applied at an early stage in an automated data analysis, before a tissue model is available.
Abstract: A novel approach to correcting for intensity nonuniformity in magnetic resonance (MR) data is described that achieves high performance without requiring a model of the tissue classes present. The method has the advantage that it can be applied at an early stage in an automated data analysis, before a tissue model is available. Described as nonparametric nonuniform intensity normalization (N3), the method is independent of pulse sequence and insensitive to pathological data that might otherwise violate model assumptions. To eliminate the dependence of the field estimate on anatomy, an iterative approach is employed to estimate both the multiplicative bias field and the distribution of the true tissue intensities. The performance of this method is evaluated using both real and simulated MR data.

4,613 citations

Journal ArticleDOI
TL;DR: The purpose of this review is to characterize the relationship of nuclear magnetic resonance measurements of water diffusion and its anisotropy (i.e. directional dependence) with the underlying microstructure of neural fibres.
Abstract: Anisotropic water diffusion in neural fibres such as nerve, white matter in spinal cord, or white matter in brain forms the basis for the utilization of diffusion tensor imaging (DTI) to track fibre pathways. The fact that water diffusion is sensitive to the underlying tissue microstructure provides a unique method of assessing the orientation and integrity of these neural fibres, which may be useful in assessing a number of neurological disorders. The purpose of this review is to characterize the relationship of nuclear magnetic resonance measurements of water diffusion and its anisotropy (i.e. directional dependence) with the underlying microstructure of neural fibres. The emphasis of the review will be on model neurological systems both in vitro and in vivo. A systematic discussion of the possible sources of anisotropy and their evaluation will be presented followed by an overview of various studies of restricted diffusion and compartmentation as they relate to anisotropy. Pertinent pathological models, developmental studies and theoretical analyses provide further insight into the basis of anisotropic diffusion and its potential utility in the nervous system.

4,216 citations

Journal ArticleDOI
TL;DR: Methods for simultaneously acquiring and subsequently combining data from a multitude of closely positioned NMR receiving coils are described, conceptually similar to phased array radar and ultrasound and hence the techniques are called the “NMR phased array.”
Abstract: We describe methods for simultaneously acquiring and subsequently combining data from a multitude of closely positioned NMR receiving coils. The approach is conceptually similar to phased array radar and ultrasound and hence we call our techniques the “NMR phased array.” The NMR phased array offers the signal-to-noise ratio (SNR) and resolution of a small surface coil over fields-of-view (FOV) normally associated with body imaging with no increase in imaging time. The NMR phased array can be applied to both imaging and spectroscopy for all pulse sequences. The problematic interactions among nearby surface coils is eliminated (a) by overlapping adjacent coils to give zero mutual inductance, hence zero interaction, and (b) by attaching low input impedance preamplifiers to all coils, thus eliminating interference among next nearest and more distant neighbors. We derive an algorithm for combining the data from the phased array elements to yield an image with optimum SNR. Other techniques which are easier to implement at the cost of lower SNR are explored. Phased array imaging is demonstrated with high resolution (512 × 512, 48-cm FOV, and 32-cm FOV) spin-echo images of the thoracic and lumbar spine. Data were acquired from four-element linear spine arrays, the first made of 12-cm square coils and the second made of 8-cm square coils. When compared with images from a single 15 × 30-cm rectangular coil and identical imaging parameters, the phased array yields a 2X and 3X higher SNR at the depth of the spine ( ∼ 7 cm). © 1990 Academic Press, Inc.

2,360 citations