scispace - formally typeset
Search or ask a question
Author

Chun Che Lin

Bio: Chun Che Lin is an academic researcher from National Cheng Kung University. The author has contributed to research in topics: Cell therapy & BDNA test. The author has an hindex of 13, co-authored 22 publications receiving 524 citations.

Papers
More filters
Journal ArticleDOI
TL;DR: Recent advancements in microfluidic sample preconcentration techniques may provide promising strategies for improving the detection sensitivities of LOC devices in many practical applications.
Abstract: Microfluidic systems have attracted considerable attention and have experienced rapid growth in the past two decades due to advantages associated with miniaturization, integration, and automation. Poor detection sensitivities mainly attributed to the small dimensions of these lab-on-a-chip (LOC) devices; however, sometimes can greatly hinder their practical applications in detecting low-abundance analytes, particularly those in bio-samples. Although off-chip sample pretreatment strategies can be used to address this problem prior to analysis, they may introduce contaminants or lead to an undesirable loss of some original sample volume. Moreover, they are often time-consuming and labor-intensive. Toward the goals of automation, improvement in analytical efficiency, and reductions in sample loss and contamination, many on-chip sample preconcentration techniques based on different working principles for improving the detection sensitivity have been developed and implemented in microchips. The aim of this article is to review recent works in microchip-based sample preconcentration techniques and give detailed discussions about these techniques. We start with a brief introduction regarding the importance of preconcentration techniques in microfluidics and the classification of these techniques based on their concentration mechanisms, followed by in-depth discussions of about these techniques. Finally, personal perspectives on microfluidic-based sample preconcentration will be provided. These advancements in microfluidic sample preconcentration techniques may provide promising strategies for improving the detection sensitivities of LOC devices in many practical applications.

108 citations

Journal ArticleDOI
TL;DR: The various miniature systems for cell culture, sorting and isolation, and stimulation are then systematically reviewed and an overview of various microfluidic systems for stem cell research is provided.
Abstract: Microfluidic techniques have been recently developed for cell-based assays. In microfluidic systems, the objective is for these microenvironments to mimic in vivo surroundings. With advantageous characteristics such as optical transparency and the capability for automating protocols, different types of cells can be cultured, screened, and monitored in real time to systematically investigate their morphology and functions under well-controlled microenvironments in response to various stimuli. Recently, the study of stem cells using microfluidic platforms has attracted considerable interest. Even though stem cells have been studied extensively using bench-top systems, an understanding of their behavior in in vivo-like microenvironments which stimulate cell proliferation and differentiation is still lacking. In this paper, recent cell studies using microfluidic systems are first introduced. The various miniature systems for cell culture, sorting and isolation, and stimulation are then systematically reviewed. The main focus of this review is on papers published in recent years studying stem cells by using microfluidic technology. This review aims to provide experts in microfluidics an overview of various microfluidic systems for stem cell research.

79 citations

Journal ArticleDOI
13 Jun 2011-Analyst
TL;DR: Advances in microfluidic techniques for urine analysis may improve current routine clinical practices, particularly for point-of-care (POC) applications.
Abstract: Microfluidics has attracted considerable attention since its early development in the 1980s and has experienced rapid growth in the past three decades due to advantages associated with miniaturization, integration and automation. Urine analysis is a common, fast and inexpensive clinical diagnostic tool in health care. In this article, we will be reviewing recent works starting from 2005 to the present for urine analysis using microfluidic devices or systems and to provide in-depth commentary about these techniques. Moreover, commercial strips that are often treated as chips and their readers for urine analysis will also be briefly discussed. We start with an introduction to the physiological significance of various components or measurement standards in urine analysis, followed by a brief introduction to enabling microfluidic technologies. Then, microfluidic devices or systems for sample pretreatments and for sensing urinary macromolecules, micromolecules, as well as multiplexed analysis are reviewed, in this sequence. Moreover, a microfluidic chip for urinary proteome profiling is also discussed, followed by a section discussing commercial products. Finally, the authors' perspectives on microfluidic-based urine analysis are provided. These advancements in microfluidic techniques for urine analysis may improve current routine clinical practices, particularly for point-of-care (POC) applications.

46 citations

Journal ArticleDOI
TL;DR: Experimental results show that a separation efficiency as high as 88% for HSCs from cord blood is achieved within 40 min for a sample volume of 100 mul, and the development of this integrated microfluidic system may be promising for various applications such as stem cell research and cell therapy.
Abstract: This study reports an integrated microfluidic system capable of isolation, counting, and sorting of hematopoietic stem cells (HSCs) from cord blood in an automatic format by utilizing a magnetic-bead-based immunoassay. Three functional modules, including cell isolation, cell counting, and cell sorting modules are integrated on a single chip by using microfluidic technology. The cell isolation module is comprised of a four-membrane-type micromixer for binding of target stem cells and magnetic beads, two pneumatic micropumps for sample transport, and an S-shaped channel for isolation of HSCs using a permanent magnet underneath. The counting and sorting of HSCs are performed by utilizing the cell counting and sorting modules. Experimental results show that a separation efficiency as high as 88% for HSCs from cord blood is achieved within 40 min for a sample volume of 100 μl. Therefore, the development of this integrated microfluidic system may be promising for various applications such as stem cell research and cell therapy.

43 citations

Journal ArticleDOI
TL;DR: This work presents a model behind the operation of a flow-through sampling chip and its application for immunoseparation, as well as its integration with a wash/elution bed for protein purification, concentration, and detection.
Abstract: This work presents a model behind the operation of a flow-through sampling chip and its application for immunoseparation, as well as its integration with a wash/elution bed for protein purification, concentration, and detection. This device used hydrodynamic pressure to drive the sample flow, and a gating voltage was applied to the electrophoretic channel on the microchip to control the sample loading for the separation and to inhibit sample leakage. The deduced model indicates that the critical gating voltage (VC) that is defined as the minimum gating voltage applied to the microchip for sampling is a function of the pump flow rate, the configuration of the microchannel on the chip, and the electroosmosis of the buffer solution. It was found that the theoretical VC values calculated from the measured electroosmotic mobilities and flow split ratios were comparable to those experimentally obtained from two microchips with different sampling channel sizes. This had an error percentage ranging from 1 to 20%....

42 citations


Cited by
More filters
01 Jan 1994
TL;DR: Micromachining technology was used to prepare chemical analysis systems on glass chips that utilize electroosmotic pumping to drive fluid flow and electrophoretic separation to distinguish sample components with no moving parts.
Abstract: Micromachining technology was used to prepare chemical analysis systems on glass chips (1 centimeter by 2 centimeters or larger) that utilize electroosmotic pumping to drive fluid flow and electrophoretic separation to distinguish sample components. Capillaries 1 to 10 centimeters long etched in the glass (cross section, 10 micrometers by 30 micrometers) allow for capillary electrophoresis-based separations of amino acids with up to 75,000 theoretical plates in about 15 seconds, and separations of about 600 plates can be effected within 4 seconds. Sample treatment steps within a manifold of intersecting capillaries were demonstrated for a simple sample dilution process. Manipulation of the applied voltages controlled the directions of fluid flow within the manifold. The principles demonstrated in this study can be used to develop a miniaturized system for sample handling and separation with no moving parts.

1,412 citations

Journal ArticleDOI
TL;DR: This chapter discusses the development of personalized medicine and home testing in the developing world, and some of the strategies used to achieve this goal have not yet been developed.
Abstract: Introduction A Why POC Diagnostics? B Time B Patient Responsibility and Compliance B Cost B Diagnostic Targets C Proteins C Metabolites and Other Small Molecules C Nucleic Acids C Human Cells D Microbes/Pathogens D Drugs and Food Safety D Current Context of POC Assays E POC Glucose Assays E Lateral Flow Assays E Limitations of “Traditional” POC Approaches F Enabling Technologies G Printing and Laminating G Microfluidic Technologies and Approaches: “Unit Operations” for POC Devices G Pumping and Valving H Mixing I Separation I Reagent Storage J Sample Preparation K Surface Chemistry and Device Substrates L Physical Adsorption L Bioaffinity Attachment L Covalent Attachment M Substrate Materials M Detection M Electrochemical Detection N Optical Detection N Magnetic Detection N Label-Free Methods O Enabling Multiplexed Assays O Recent Innovation O Lateral Flow Assay Technologies O Proteins P Antibodies P Protein Expression and Purification Q Nucleic Acids Q Aptamers R Infectious Diseases and Food/Water Safety R Blood Chemistry S Coagulation Markers S Whole Cells S Trends, Unmet Needs, Perspectives T Glucose T Global Health and the Developing World T Personalized Medicine and Home Testing U Technology Trends U Multiplexing V Author Information V Biographies V Acknowledgment W References W

983 citations

Journal ArticleDOI
TL;DR: A high level overview of the field of microfluidic mixing devices is provided before describing some of the more significant proposals for active and passive mixers.
Abstract: The aim of microfluidic mixing is to achieve a thorough and rapid mixing of multiple samples in microscale devices. In such devices, sample mixing is essentially achieved by enhancing the diffusion effect between the different species flows. Broadly speaking, microfluidic mixing schemes can be categorized as either “active”, where an external energy force is applied to perturb the sample species, or “passive”, where the contact area and contact time of the species samples are increased through specially-designed microchannel configurations. Many mixers have been proposed to facilitate this task over the past 10 years. Accordingly, this paper commences by providing a high level overview of the field of microfluidic mixing devices before describing some of the more significant proposals for active and passive mixers.

910 citations

Journal ArticleDOI
TL;DR: This review outlines some of the advantages and challenges that may accompany a transition from macroscopic to microfluidic cell culture and focuses on decisive factors that distinguish Macroscopic from microfluidity cell culture to encourage a reconsideration of how macroscopy cell culture principles might apply to micro fluidiccell culture.

760 citations

Journal ArticleDOI
TL;DR: This review deals with the application of optical sensing systems for microfluidic devices, in the "off-chip approach" macro-scale optical infrastructure is coupled, while the "on- chip approach" comprises the integration of micro-optical functions into microfluidity devices.

434 citations