scispace - formally typeset
Search or ask a question
Author

Craig Walther

Bio: Craig Walther is an academic researcher from National Oceanic and Atmospheric Administration. The author has contributed to research in topics: Water vapor & Boundary layer. The author has an hindex of 2, co-authored 2 publications receiving 102 citations.

Papers
More filters
Journal ArticleDOI
TL;DR: The most important features of the DIAL technique are introduced: its clear-air measurement capability, its flexibility, and its simultaneous high resolution and accuracy.
Abstract: The performance of a future advanced water-vapor differential absorption lidar (DIAL) system is discussed. It is shown that the system has to be a direct-detection system operating in the rhovarsigmatau band of water vapor in the 940-nm wavelength region. The most important features of the DIAL technique are introduced: its clear-air measurement capability, its flexibility, and its simultaneous high resolution and accuracy. It is demonstrated that such a DIAL system can contribute to atmospheric sciences over a large range of scales and over a large variety of humidity conditions. An extended error analysis is performed, and errors (e.g., speckle noise) are included that previously were not been discussed in detail and that become important for certain system designs and measurement conditions. The applicability of the derived equation is investigated by comparisons with real data. Excellent agreement is found.

60 citations

Journal ArticleDOI
TL;DR: Taking into account Poisson, background, amplifier, and speckle noise, the precision of water-vapor measurements can be simulated by using a 10-W average-power differential absorption lidar (DIAL) system, which is currently under development at Hohenheim University, Germany, and at the American National Center for Atmospheric Research.
Abstract: Taking into account Poisson, background, amplifier, and speckle noise, we can simulate the precision of water-vapor measurements by using a 10-W average-power differential absorption lidar (DIAL) system. This system is currently under development at Hohenheim University, Germany, and at the American National Center for Atmospheric Research. For operation in the 940-nm region, a large set of measurement situations is described, including configurations that are considered for the first time to the authors' knowledge. They include ultrahigh-resolution measurements in the surface layer (resolutions, 1.5 m and 0.1 s) and vertically pointing measurements (resolutions, 30 m and 1 s) from the ground to 2 km in the atmospheric boundary layer. Even during daytime, the DIAL system will have a measurement range from the ground to the upper troposphere (300 m, 10 min) that can be extended from a mountain site to the lower stratosphere. From the ground, for the first time of which the authors are aware, three-dimensional fields of water vapor in the boundary layer can be investigated within a range of the order of 15 km and with an averaging time of 10 min. From an aircraft, measurements of the atmospheric boundary layer (60 m, 1 s) can be performed from a height of 4 km to the ground. At higher altitudes, up to 18 km, water-vapor profiles can still be obtained from aircraft height level to the ground. When it is being flown either in the free troposphere or in the stratosphere, the system will measure horizontal water-vapor profiles up to 12 km. We are not aware of another remote-sensing technique that provides, simultaneously, such high resolution and accuracy.

42 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: The COPS field phase was performed from 1 June to 31 August 2007 in a low-mountain area in southwestern Germany/eastern France covering the Vosges mountains, the Rhine valley and the Black Forest mountains.
Abstract: Within the framework of the international field campaign COPS (Convective and Orographically induced Precipitation Study), a large suite of state-of-the-art meteorological instrumentation was operated, partially combined for the first time. This includes networks of in situ and remote-sensing systems such as the Global Positioning System as well as a synergy of multi-wavelength passive and active remote-sensing instruments such as advanced radar and lidar systems. The COPS field phase was performed from 01 June to 31 August 2007 in a low-mountain area in southwestern Germany/eastern France covering the Vosges mountains, the Rhine valley and the Black Forest mountains. The collected dataset covers the entire evolution of convective precipitation events in complex terrain from their initiation, to their development and mature phase until their decay. Eighteen Intensive Observations Periods with 37 operation days and eight additional Special Observations Periods were performed, providing a comprehensive dataset covering different forcing conditions. In this article, an overview of the COPS scientific strategy, the field phase, and its first accomplishments is given. Highlights of the campaign are illustrated with several measurement examples. It is demonstrated that COPS research provides new insight into key processes leading to convection initiation and to the modification of precipitation by orography, in the improvement of quantitative precipitation forecasting by the assimilation of new observations, and in the performance of ensembles of convection-permitting models in complex terrain.

215 citations

Journal ArticleDOI
TL;DR: In this article, a review of remote sensing technology for lower-tropospheric thermodynamic profiling is presented with focus on high accuracy and high temporal-vertical resolution, and the contributions of these instruments to the understanding of the Earth system are assessed with respect to radiative transfer, land-surface-atmosphere feedback, convection initiation, and data assimilation.
Abstract: A review of remote sensing technology for lower-tropospheric thermodynamic (TD) profiling is presented with focus on high accuracy and high temporal-vertical resolution. The contributions of these instruments to the understanding of the Earth system are assessed with respect to radiative transfer, land-surface-atmosphere feedback, convection initiation, and data assimilation. We demonstrate that for progress in weather and climate research, TD profilers are essential. These observational systems must resolve gradients of humidity and temperature in the stable or unstable atmospheric surface layer close to the ground, in the mixed layer, in the interfacial layer – usually characterized by an inversion – and the lower troposphere. A thorough analysis of the current observing systems is performed revealing significant gaps that must be addressed to fulfill existing needs. We analyze whether current and future passive and active remote sensing systems can close these gaps. A methodological analysis and demonstration of measurement capabilities with respect to bias and precision is executed both for passive and active remote sensing including passive infrared and microwave spectroscopy, the global positioning system as well as water-vapor and temperature Raman lidar and water-vapor differential absorption lidar. Whereas passive remote sensing systems are already mature with respect to operational applications, active more » remote sensing systems require further engineering to become operational in networks. However, active remote sensing systems provide a smaller bias as well as higher temporal and vertical resolutions. For a suitable mesoscale network design, TD profiler system developments should be intensified and dedicated observing system simulation experiments should be performed. « less

171 citations

Journal ArticleDOI
TL;DR: In this paper, a field-deployable water vapor profiling instrument that builds on the foundation of the preceding generations of diode-laser-based differential absorption lidar (DIAL) laboratory prototypes was constructed and tested.
Abstract: . A field-deployable water vapor profiling instrument that builds on the foundation of the preceding generations of diode-laser-based differential absorption lidar (DIAL) laboratory prototypes was constructed and tested. Significant advances are discussed, including a unique shared telescope design that allows expansion of the outgoing beam for eye-safe operation with optomechanical and thermal stability; multistage optical filtering enabling measurement during daytime bright-cloud conditions; rapid spectral switching between the online and offline wavelengths enabling measurements during changing atmospheric conditions; and enhanced performance at lower ranges by the introduction of a new filter design and the addition of a wide field-of-view channel. Performance modeling, testing, and intercomparisons are performed and discussed. In general, the instrument has a 150 m range resolution with a 10 min temporal resolution; 1 min temporal resolution in the lowest 2 km of the atmosphere is demonstrated. The instrument is shown capable of autonomous long-term field operation – 50 days with a > 95% uptime – under a broad set of atmospheric conditions and potentially forms the basis for a ground-based network of eye-safe autonomous instruments needed for the atmospheric sciences research and forecasting communities.

99 citations

Journal ArticleDOI
TL;DR: In this article, high-resolution water vapour measurements made by the Atmospheric Radiation Measurement (ARM) Raman lidar operated at the Southern Great Plains Climate Research Facility site near Lamont, Oklahoma, U.S.A. are presented.
Abstract: High-resolution water vapour measurements made by the Atmospheric Radiation Measurement (ARM) Raman lidar operated at the Southern Great Plains Climate Research Facility site near Lamont, Oklahoma, U.S.A. are presented. Using a 2-h measurement period for the convective boundary layer (CBL) on 13 September 2005, with temporal and spatial resolutions of 10 s and 75 m, respectively, spectral and autocovariance analyses of water vapour mixing ratio time series are performed. It is demonstrated that the major part of the inertial subrange was detected and that the integral scale was significantly larger than the time resolution. Consequently, the major part of the turbulent fluctuations was resolved. Different methods to retrieve noise error profiles yield consistent results and compare well with noise profiles estimated using Poisson statistics of the Raman lidar signals. Integral scale, mixing-ratio variance, skewness, and kurtosis profiles were determined including error bars with respect to statistical and sampling errors. The integral scale ranges between 70 and 130 s at the top of the CBL. Within the CBL, up to the third order, noise errors are significantly smaller than sampling errors and the absolute values of turbulent variables, respectively. The mixing-ratio variance profile rises monotonically from ≈0.07 to ≈3.7 g2 kg−2 in the entrainment zone. The skewness is nearly zero up to 0.6 z/z i , becomes −1 around 0.7–0.8 z/z i , crosses zero at about 0.95 z/z i , and reaches about 1.7 at 1.1 z/z i (here, z is the height and z i is the CBL depth). The noise errors are too large to derive fourth-order moments with sufficient accuracy. Consequently, to the best of our knowledge, the ARM Raman lidar is the first water vapour Raman lidar with demonstrated capability to retrieve profiles of turbulent variables up to the third order during daytime throughout the atmospheric CBL.

79 citations

Journal ArticleDOI
TL;DR: A pulsed, diode-laser-pumped Nd:YAG master oscillator power amplifier in rod geometry, frequency stabilized with a modified Pound-Drever-Hall scheme is presented, which will be the pump laser of transmitters for a variety of high-end, scanning lidar systems.
Abstract: A pulsed, diode-laser-pumped Nd:YAG master oscillator power amplifier (MOPA) in rod geometry, frequency stabilized with a modified Pound-Drever-Hall scheme is presented. The apparatus delivers 33-ns pulses with a maximum pulse energy of 0.5 J at 1064 nm. The system was set up in two different configurations for repetition rates of 100 or 250 Hz. The beam quality was measured to be 1.5 times the diffraction limit at a pulse energy of 405 mJ and a repetition rate of 100 Hz. At 250 Hz with the same pulse energy, the M2 was better than 2.1. The radiation is frequency converted with an efficiency of 50% to 532 nm. This MOPA system will be the pump laser of transmitters for a variety of high-end, scanning lidar systems.

79 citations