scispace - formally typeset
Search or ask a question
Author

D. Black

Bio: D. Black is an academic researcher from University of Utah. The author has contributed to research in topics: Power module & Low-power electronics. The author has an hindex of 5, co-authored 6 publications receiving 987 citations.

Papers
More filters
Journal ArticleDOI
26 Dec 2006
TL;DR: A prototype integrated circuit for wireless neural recording from a 100-channel microelectrode array was developed and a two-chip system was used to record neural signals from a Utah Electrode Array in cat cortex and transmit the digitized signals wirelessly to a receiver.
Abstract: Recent work in field of neuroprosthetics has demonstrated that by observing the simultaneous activity of many neurons in specific regions of the brain, it is possible to produce control signals that allow animals or humans to drive cursors or prosthetic limbs directly through thoughts. As neuroprosthetic devices transition from experimental to clinical use, there is a need for fully-implantable amplification and telemetry electronics in close proximity to the recording sites. To address these needs, we developed a prototype integrated circuit for wireless neural recording from a 100-channel microelectrode array. The design of both the system-level architecture and the individual circuits were driven by severe power constraints for small implantable devices; chronically heating tissue by only a few degrees Celsius leads to cell death. Due to the high data rate produced by 100 neural signals, the system must perform data reduction as well. We use a combination of a low-power ADC and an array of "spike detectors" to reduce the transmitted data rate while preserving critical information. The complete system receives power and commands (at 6.5 kb/s) wirelessly over a 2.64-MHz inductive link and transmits neural data back at a data rate of 330 kb/s using a fully-integrated 433-MHz FSK transmitter. The 4.7times5.9 mm2 chip was fabricated in a 0.5-mum 3M2P CMOS process and consumes 13.5 mW of power. While cross-chip interference limits performance in single-chip operation, a two-chip system was used to record neural signals from a Utah Electrode Array in cat cortex and transmit the digitized signals wirelessly to a receiver

927 citations

Journal ArticleDOI
TL;DR: The power receiving coils presented in this paper were designed to maximize the inductance and quality factor of the coils and microfabricated using polymer based thin film technologies.
Abstract: Reliable chronic operation of implantable medical devices such as the Utah Electrode Array (UEA) for neural interface requires elimination of transcutaneous wire connections for signal processing, powering and communication of the device. A wireless power source that allows integration with the UEA is therefore necessary. While (rechargeable) micro-batteries as well as biological micro-fuel cells are yet far from meeting the power density and lifetime requirements of an implantable neural interface device, inductive coupling between two coils is a promising approach to power such a device with highly restricted dimensions. The power receiving coils presented in this paper were designed to maximize the inductance and quality factor of the coils and microfabricated using polymer-based thin film technologies. A flexible configuration of stacked thin film coils allows parallel and serial switching, thereby allowing to tune the coil's resonance frequency. The electrical properties of the fabricated coils were characterized and their power transmission performance was investigated in laboratory condition.

46 citations

Proceedings ArticleDOI
P.T. Watkins1, R.J. Kier1, R.O. Lovejoy1, D. Black1, Reid R. Harrison1 
21 May 2006
TL;DR: A low-power integrated circuit that performs power rectification and regulation, reception of configuration data, Neural signal amplification and filtering, spike detection, neural signal digitization and RF transmission is developed.
Abstract: We are developing a fully-implantable neural recording system with wireless power and data transfer. As part of this system, we have developed a low-power integrated circuit that performs power rectification and regulation, reception of configuration data, neural signal amplification and filtering, spike detection, neural signal digitization and RF transmission. The chip includes 88 amplifiers having a gain of 60 dB from 1 to 5 kHz. An integrated ADC operates at 15 kSamples/sec with 9-bit resolution. A 433-MHz RF transmitter uses FSK modulation to transmit one digitized neural signal and spike detection data from all channels. Total power consumption is 13.5 mW.

15 citations

Proceedings ArticleDOI
06 Jan 2007
TL;DR: The authors have developed a single-chip neural recording system with wireless power delivery and telemetry with data reduction by incorporating one-bit "spike detectors" into each amplifier.
Abstract: The authors have developed a single-chip neural recording system with wireless power delivery and telemetry. The 0.5-mum CMOS IC is designed to be bonded to the back of a 100-channel Utah electrode array. A pad near each amplifier allows connection of the chip to the MEMS electrode array. The complete integrated neural interface receives power wirelessly through a 2.64-MHz inductive link. A clock, regulated supply, and commands are derived from the power signal .The neural amplifiers each have a gain of 60 dB. A 10-bit charge-redistribution ADC is used to digitize the signal from one amplifier selected with an analog MUX. Digitizing all channels simultaneously would generate prohibitively high data rates; therefore, the authors perform data reduction by incorporating one-bit "spike detectors" into each amplifier. Neural data is transmitted off chip using an integrated 433-MHz FSK transmitter. The chip measures 4.7 times 5.9 mm and consumes 13.5 mW of power

8 citations

Proceedings ArticleDOI
28 Aug 2006
TL;DR: In this paper, an inductive coupling between two coils was used to deliver power to the integrated electronics, and the power receiver coil was microfabricated as a polymer-based component, and its electrical characteristics and performance in power transmission were investigated.
Abstract: For the conventional Utah electrode array (UEA) to be able to function without transcutaneous wire connections, a kind of power source is needed in an integrated form with the UEA. To develop such wireless neural interfaces, inductive coupling between two coils was used to deliver power to the integrated electronics. The power receiver coil was microfabricated as a polymer based component, and its electrical characteristics and performance in power transmission were investigated in dry condition.

5 citations


Cited by
More filters
Journal ArticleDOI
26 Dec 2006
TL;DR: A prototype integrated circuit for wireless neural recording from a 100-channel microelectrode array was developed and a two-chip system was used to record neural signals from a Utah Electrode Array in cat cortex and transmit the digitized signals wirelessly to a receiver.
Abstract: Recent work in field of neuroprosthetics has demonstrated that by observing the simultaneous activity of many neurons in specific regions of the brain, it is possible to produce control signals that allow animals or humans to drive cursors or prosthetic limbs directly through thoughts. As neuroprosthetic devices transition from experimental to clinical use, there is a need for fully-implantable amplification and telemetry electronics in close proximity to the recording sites. To address these needs, we developed a prototype integrated circuit for wireless neural recording from a 100-channel microelectrode array. The design of both the system-level architecture and the individual circuits were driven by severe power constraints for small implantable devices; chronically heating tissue by only a few degrees Celsius leads to cell death. Due to the high data rate produced by 100 neural signals, the system must perform data reduction as well. We use a combination of a low-power ADC and an array of "spike detectors" to reduce the transmitted data rate while preserving critical information. The complete system receives power and commands (at 6.5 kb/s) wirelessly over a 2.64-MHz inductive link and transmits neural data back at a data rate of 330 kb/s using a fully-integrated 433-MHz FSK transmitter. The 4.7times5.9 mm2 chip was fabricated in a 0.5-mum 3M2P CMOS process and consumes 13.5 mW of power. While cross-chip interference limits performance in single-chip operation, a two-chip system was used to record neural signals from a Utah Electrode Array in cat cortex and transmit the digitized signals wirelessly to a receiver

927 citations

Journal ArticleDOI
TL;DR: This work outlined the theoretical foundation of optimal power transmission efficiency in an inductive link, and combined it with semi-empirical models to predict parasitic components in PSCs to devise an iterative PSC design methodology that starts with a set of realistic design constraints and ends with the optimal PSC pair geometries.
Abstract: The next generation of implantable high-power neuroprosthetic devices such as visual prostheses and brain computer interfaces are going to be powered by transcutaneous inductive power links formed between a pair of printed spiral coils (PSC) that are batch-fabricated using micromachining technology. Optimizing the power efficiency of the wireless link is imperative to minimize the size of the external energy source, heating dissipation in the tissue, and interference with other devices. Previous design methodologies for coils made of 1-D filaments are not comprehensive and accurate enough to consider all geometrical aspects of PSCs with planar 3-D conductors as well as design constraints imposed by implantable device application and fabrication technology. We have outlined the theoretical foundation of optimal power transmission efficiency in an inductive link, and combined it with semi-empirical models to predict parasitic components in PSCs. We have used this foundation to devise an iterative PSC design methodology that starts with a set of realistic design constraints and ends with the optimal PSC pair geometries. We have executed this procedure on two design examples at 1 and 5 MHz achieving power transmission efficiencies of 41.2% and 85.8%, respectively, at 10-mm spacing. All results are verified with simulations using a commercial field solver (HFSS) as well as measurements using PSCs fabricated on printed circuit boards.

616 citations

Journal ArticleDOI
TL;DR: It is shown that despite achieving high PTE at larger coil separations, the 4-coil inductive links fail to achieve a high PDL, and an iterative design methodology is devised that provides the optimal coil geometries in a 3-coils inductive power transfer link.
Abstract: Inductive power transmission is widely used to energize implantable microelectronic devices (IMDs), recharge batteries, and energy harvesters. Power transfer efficiency (PTE) and power delivered to the load (PDL) are two key parameters in wireless links, which affect the energy source specifications, heat dissipation, power transmission range, and interference with other devices. To improve the PTE, a 4-coil inductive link has been recently proposed. Through a comprehensive circuit-based analysis that can guide a design and optimization scheme, we have shown that despite achieving high PTE at larger coil separations, the 4-coil inductive links fail to achieve a high PDL. Instead, we have proposed a 3-coil inductive power transfer link with comparable PTE over its 4-coil counterpart at large coupling distances, which can also achieve high PDL. We have also devised an iterative design methodology that provides the optimal coil geometries in a 3-coil inductive power transfer link. Design examples of 2-, 3-, and 4-coil inductive links have been presented, and optimized for a 13.56-MHz carrier frequency and 12-cm coupling distance, showing PTEs of 15%, 37%, and 35%, respectively. At this distance, the PDL of the proposed 3-coil inductive link is 1.5 and 59 times higher than its equivalent 2- and 4-coil links, respectively. For short coupling distances, however, 2-coil links remain the optimal choice when a high PDL is required, while 4-coil links are preferred when the driver has large output resistance or small power is needed. These results have been verified through simulations and measurements.

537 citations

Journal ArticleDOI
TL;DR: The amplifier appears to be the lowest power and most energy-efficient neural recording amplifier reported to date and the low-noise design techniques that help the neural amplifier achieve input-referred noise that is near the theoretical limit of any amplifier using a differential pair as an input stage.
Abstract: This paper describes an ultralow-power neural recording amplifier. The amplifier appears to be the lowest power and most energy-efficient neural recording amplifier reported to date. We describe low-noise design techniques that help the neural amplifier achieve input-referred noise that is near the theoretical limit of any amplifier using a differential pair as an input stage. Since neural amplifiers must include differential input pairs in practice to allow robust rejection of common-mode and power supply noise, our design appears to be near the optimum allowed by theory. The bandwidth of the amplifier can be adjusted for recording either neural spikes or local field potentials (LFPs). When configured for recording neural spikes, the amplifier yielded a midband gain of 40.8 dB and a -3-dB bandwidth from 45 Hz to 5.32 kHz; the amplifier's input-referred noise was measured to be 3.06 muVrms while consuming 7.56 muW of power from a 2.8-V supply corresponding to a noise efficiency factor (NEF) of 2.67 with the theoretical limit being 2.02. When configured for recording LFPs, the amplifier achieved a midband gain of 40.9 dB and a -3-dB bandwidth from 392 mHz to 295 Hz; the input-referred noise was 1.66 muVrms while consuming 2.08 muW from a 2.8-V supply corresponding to an NEF of 3.21. The amplifier was fabricated in AMI's 0.5-mum CMOS process and occupies 0.16 mm2 of chip area. We obtained successful recordings of action potentials from the robust nucleus of the arcopallium (RA) of an anesthesized zebra finch brain with the amplifier. Our experimental measurements of the amplifier's performance including its noise were in good accord with theory and circuit simulations.

463 citations

Journal ArticleDOI
TL;DR: An overview of state-of-the-art microelectrode technologies provided, with focus on the material properties of these microdevices for the development of long-lasting functional neural interfaces is provided.
Abstract: Recent advances in nanotechnology have generated wide interest in applying nanomaterials for neural prostheses. An ideal neural interface should create seamless integration into the nervous system and performs reliably for long periods of time. As a result, many nanoscale materials not originally developed for neural interfaces become attractive candidates to detect neural signals and stimulate neurons. In this comprehensive review, an overview of state-of-the-art microelectrode technologies provided fi rst, with focus on the material properties of these microdevices. The advancements in electro active nanomaterials are then reviewed, including conducting polymers, carbon nanotubes, graphene, silicon nanowires, and hybrid organic-inorganic nanomaterials, for neural recording, stimulation, and growth. Finally, technical and scientific challenges are discussed regarding biocompatibility, mechanical mismatch, and electrical properties faced by these nanomaterials for the development of long-lasting functional neural interfaces.

461 citations