Author
D. M. Mei
Bio: D. M. Mei is an academic researcher from University of South Dakota. The author has contributed to research in topics: WIMP & Dark matter. The author has an hindex of 12, co-authored 16 publications receiving 2683 citations.
Papers
More filters
••
Case Western Reserve University1, University of Wisconsin-Madison2, Imperial College London3, South Dakota School of Mines and Technology4, University of Maryland, College Park5, University of California, Berkeley6, Lawrence Livermore National Laboratory7, University of Coimbra8, University of South Dakota9, Yale University10, University of California, Santa Barbara11, Brown University12, University of California, Davis13, Lawrence Berkeley National Laboratory14, University College London15, University of Rochester16, SLAC National Accelerator Laboratory17, Texas A&M University18, State University of New York System19, University of Edinburgh20
TL;DR: This search yields no evidence of WIMP nuclear recoils and constraints on spin-independent weakly interacting massive particle (WIMP)-nucleon scattering using a 3.35×10^{4} kg day exposure of the Large Underground Xenon experiment are reported.
Abstract: We report constraints on spin-independent weakly interacting massive particle (WIMP)-nucleon scattering using a 3.35×10^{4} kg day exposure of the Large Underground Xenon (LUX) experiment. A dual-phase xenon time projection chamber with 250 kg of active mass is operated at the Sanford Underground Research Facility under Lead, South Dakota (USA). With roughly fourfold improvement in sensitivity for high WIMP masses relative to our previous results, this search yields no evidence of WIMP nuclear recoils. At a WIMP mass of 50 GeV c^{-2}, WIMP-nucleon spin-independent cross sections above 2.2×10^{-46} cm^{2} are excluded at the 90% confidence level. When combined with the previously reported LUX exposure, this exclusion strengthens to 1.1×10^{-46} cm^{2} at 50 GeV c^{-2}.
1,844 citations
••
Case Western Reserve University1, Imperial College London2, South Dakota School of Mines and Technology3, University of Maryland, College Park4, University of Edinburgh5, Yale University6, Lawrence Livermore National Laboratory7, University of California, Santa Barbara8, Brown University9, University of South Dakota10, University of California, Davis11, University of Coimbra12, Lawrence Berkeley National Laboratory13, University College London14, University of Rochester15, University of California, Berkeley16, SLAC National Accelerator Laboratory17, Texas A&M University18, State University of New York System19
TL;DR: This new analysis incorporates several advances: single-photon calibration at the scintillation wavelength, improved event-reconstruction algorithms, a revised background model including events originating on the detector walls in an enlarged fiducial volume, and new calibrations from decays of an injected tritium β source and from kinematically constrained nuclear recoils down to 1.1 keV.
Abstract: We present constraints on weakly interacting massive particles (WIMP)-nucleus scattering from the 2013 data of the Large Underground Xenon dark matter experiment, including 1.4×10^{4} kg day of search exposure. This new analysis incorporates several advances: single-photon calibration at the scintillation wavelength, improved event-reconstruction algorithms, a revised background model including events originating on the detector walls in an enlarged fiducial volume, and new calibrations from decays of an injected tritium β source and from kinematically constrained nuclear recoils down to 1.1 keV. Sensitivity, especially to low-mass WIMPs, is enhanced compared to our previous results which modeled the signal only above a 3 keV minimum energy. Under standard dark matter halo assumptions and in the mass range above 4 GeV c^{-2}, these new results give the most stringent direct limits on the spin-independent WIMP-nucleon cross section. The 90% C.L. upper limit has a minimum of 0.6 zb at 33 GeV c^{-2} WIMP mass.
460 citations
••
Case Western Reserve University1, Imperial College London2, South Dakota School of Mines and Technology3, University of Maryland, College Park4, University of Edinburgh5, Yale University6, Lawrence Livermore National Laboratory7, University of California, Santa Barbara8, Brown University9, University of South Dakota10, University of California, Davis11, University of Coimbra12, Lawrence Berkeley National Laboratory13, University College London14, University of Rochester15, University of California, Berkeley16, SLAC National Accelerator Laboratory17, Texas A&M University18, State University of New York System19
TL;DR: The spin-dependent WIMP-neutron limit is the most sensitive constraint to date.
Abstract: We present experimental constraints on the spin-dependent WIMP (weakly interacting massive particle)-nucleon elastic cross sections from LUX data acquired in 2013. LUX is a dual-phase xenon time projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), which is designed to observe the recoil signature of galactic WIMPs scattering from xenon nuclei. A profile likelihood ratio analysis of 1.4×10^{4} kg day of fiducial exposure allows 90% C.L. upper limits to be set on the WIMP-neutron (WIMP-proton) cross section of σ_{n}=9.4×10^{-41} cm^{2} (σ_{p}=2.9×10^{-39} cm^{2}) at 33 GeV/c^{2}. The spin-dependent WIMP-neutron limit is the most sensitive constraint to date.
195 citations
••
Pacific Northwest National Laboratory1, Lawrence Berkeley National Laboratory2, University of Washington3, University of South Carolina4, North Carolina State University5, Kurchatov Institute6, University of Chicago7, University of South Dakota8, Oak Ridge National Laboratory9, Max Planck Society10, South Dakota School of Mines and Technology11, Durham University12, Joint Institute for Nuclear Research13, Los Alamos National Laboratory14, University of Tennessee15, Osaka University16, University of Alberta17, Black Hills State University18, Queen's University19
TL;DR: The Majorana Demonstrator as discussed by the authors achieved an energy resolution of 2.5 keV FWHM at Qββ and a very low background with no observed candidate events in 9.95 kg yr of enriched Ge exposure, resulting in a lower limit on the half-life of 1.9×10−25−25 −1.
Abstract: The Majorana Collaboration is operating an array of high purity Ge detectors to search for neutrinoless double-β decay in ^{76}Ge. The Majorana Demonstrator comprises 44.1 kg of Ge detectors (29.7 kg enriched in ^{76}Ge) split between two modules contained in a low background shield at the Sanford Underground Research Facility in Lead, South Dakota. Here we present results from data taken during construction, commissioning, and the start of full operations. We achieve unprecedented energy resolution of 2.5 keV FWHM at Q_{ββ} and a very low background with no observed candidate events in 9.95 kg yr of enriched Ge exposure, resulting in a lower limit on the half-life of 1.9×10^{25} yr (90% C.L.). This result constrains the effective Majorana neutrino mass to below 240-520 meV, depending on the matrix elements used. In our experimental configuration with the lowest background, the background is 4.0_{-2.5}^{+3.1} counts/(FWHM t yr).
182 citations
••
TL;DR: In this paper, the electron-recoil (ER) response of the LUX dark matter detector based upon 170 000 highly pure and spatially uniform tritium decays is investigated.
Abstract: We present measurements of the electron-recoil (ER) response of the LUX dark matter detector based upon 170 000 highly pure and spatially uniform tritium decays. We reconstruct the tritium energy spectrum using the combined energy model and find good agreement with expectations. We report the average charge and light yields of ER events in liquid xenon at 180 and 105 V/cm and compare the results to the NEST model. We also measure the mean charge recombination fraction and its fluctuations, and we investigate the location and width of the LUX ER band. These results provide input to a reanalysis of the LUX run 3 weakly interacting massive particle search.
92 citations
Cited by
More filters
••
Columbia University1, University of Amsterdam2, University of Bologna3, University of Mainz4, University of Münster5, University of Coimbra6, New York University Abu Dhabi7, University of Zurich8, Stockholm University9, Rensselaer Polytechnic Institute10, Max Planck Society11, Weizmann Institute of Science12, University of Freiburg13, University of Nantes14, University of California, San Diego15, University of Chicago16, Purdue University17, Rice University18, Pierre-and-Marie-Curie University19, University of California, Los Angeles20
TL;DR: In this article, a search for weakly interacting massive particles (WIMPs) using 278.8 days of data collected with the XENON1T experiment at LNGS is reported.
Abstract: We report on a search for weakly interacting massive particles (WIMPs) using 278.8 days of data collected with the XENON1T experiment at LNGS. XENON1T utilizes a liquid xenon time projection chamber with a fiducial mass of (1.30±0.01) ton, resulting in a 1.0 ton yr exposure. The energy region of interest, [1.4,10.6] keVee ([4.9,40.9] keVnr), exhibits an ultralow electron recoil background rate of [82-3+5(syst)±3(stat)] events/(ton yr keVee). No significant excess over background is found, and a profile likelihood analysis parametrized in spatial and energy dimensions excludes new parameter space for the WIMP-nucleon spin-independent elastic scatter cross section for WIMP masses above 6 GeV/c2, with a minimum of 4.1×10-47 cm2 at 30 GeV/c2 and a 90% confidence level.
1,808 citations
••
Columbia University1, University of Amsterdam2, University of Mainz3, University of Coimbra4, New York University Abu Dhabi5, University of Zurich6, Stockholm University7, Rensselaer Polytechnic Institute8, Max Planck Society9, Weizmann Institute of Science10, University of Freiburg11, Purdue University12, University of Nantes13, University of Bologna14, University of California, San Diego15, University of Münster16, University of Chicago17, Rice University18, Pierre-and-Marie-Curie University19, University of California, Los Angeles20
TL;DR: The first dark matter search results from XENON1T, a ∼2000-kg-target-mass dual-phase (liquid-gas) xenon time projection chamber in operation at the Laboratori Nazionali del Gran Sasso in Italy, are reported and a profile likelihood analysis shows that the data are consistent with the background-only hypothesis.
Abstract: We report the first dark matter search results from XENON1T, a ∼2000-kg-target-mass dual-phase (liquid-gas) xenon time projection chamber in operation at the Laboratori Nazionali del Gran Sasso in Italy and the first ton-scale detector of this kind The blinded search used 342 live days of data acquired between November 2016 and January 2017 Inside the (1042±12)-kg fiducial mass and in the [5,40] keVnr energy range of interest for weakly interacting massive particle (WIMP) dark matter searches, the electronic recoil background was (193±025)×10-4 events/(kg×day×keVee), the lowest ever achieved in such a dark matter detector A profile likelihood analysis shows that the data are consistent with the background-only hypothesis We derive the most stringent exclusion limits on the spin-independent WIMP-nucleon interaction cross section for WIMP masses above 10 GeV/c2, with a minimum of 77×10-47 cm2 for 35-GeV/c2 WIMPs at 90% CL
1,061 citations
••
TL;DR: A review of the WIMP paradigm with focus on a few models which can be probed at best by these facilities, and Collider and Indirect Detection will not be neglected when they represent a complementary probe.
Abstract: Weakly Interacting Massive Particles (WIMPs) are among the best-motivated dark matter candidates. No conclusive signal, despite an extensive search program that combines, often in a complementary way, direct, indirect, and collider probes, has been detected so far. This situation might change in near future due to the advent of one/multi-TON Direct Detection experiments. We thus, find it timely to provide a review of the WIMP paradigm with focus on a few models which can be probed at best by these facilities. Collider and Indirect Detection, nevertheless, will not be neglected when they represent a complementary probe.
772 citations
••
Columbia University1, University of Amsterdam2, University of Bologna3, University of Mainz4, University of Coimbra5, Weizmann Institute of Science6, New York University Abu Dhabi7, University of Zurich8, Stockholm University9, Rensselaer Polytechnic Institute10, Max Planck Society11, University of Münster12, University of Bern13, Purdue University14, École des mines de Nantes15, University of California, Los Angeles16, Rice University17
TL;DR: In this article, the expected sensitivity of the Xenon1T experiment to the spin-independent WIMP-nucleon interaction cross section was investigated based on Monte Carlo predictions of the electronic and nuclear recoil backgrounds.
Abstract: The XENON1T experiment is currently in the commissioning phase at the Laboratori Nazionali del Gran Sasso, Italy. In this article we study the experiment's expected sensitivity to the spin-independent WIMP-nucleon interaction cross section, based on Monte Carlo predictions of the electronic and nuclear recoil backgrounds. The total electronic recoil background in 1 tonne fiducial volume and (1, 12) keV electronic recoil equivalent energy region, before applying any selection to discriminate between electronic and nuclear recoils, is (1.80 ± 0.15) · 10(−)(4) (kg·day·keV)(−)(1), mainly due to the decay of (222)Rn daughters inside the xenon target. The nuclear recoil background in the corresponding nuclear recoil equivalent energy region (4, 50) keV, is composed of (0.6 ± 0.1) (t·y)(−)(1) from radiogenic neutrons, (1.8 ± 0.3) · 10(−)(2) (t·y)(−)(1) from coherent scattering of neutrinos, and less than 0.01 (t·y)(−)(1) from muon-induced neutrons. The sensitivity of XENON1T is calculated with the Profile Likelihood Ratio method, after converting the deposited energy of electronic and nuclear recoils into the scintillation and ionization signals seen in the detector. We take into account the systematic uncertainties on the photon and electron emission model, and on the estimation of the backgrounds, treated as nuisance parameters. The main contribution comes from the relative scintillation efficiency Script L(eff), which affects both the signal from WIMPs and the nuclear recoil backgrounds. After a 2 y measurement in 1 t fiducial volume, the sensitivity reaches a minimum cross section of 1.6 · 10(−)(47) cm(2) at m(χ) = 50 GeV/c(2).
580 citations
••
University of Amsterdam1, University of Bologna2, University of Mainz3, University of Coimbra4, University of Bern5, Columbia University6, Weizmann Institute of Science7, New York University Abu Dhabi8, University of Zurich9, Rensselaer Polytechnic Institute10, Max Planck Society11, Stockholm University12, University of Nantes13, Karlsruhe Institute of Technology14, University of Münster15, University of Chicago16, Arizona State University17, Purdue University18, Rice University19, University of California, San Diego20, University of Freiburg21, Dresden University of Technology22, Imperial College London23, University of California, Los Angeles24
TL;DR: DARk matter WImp search with liquid xenoN (DARWIN) as mentioned in this paper is an experiment for the direct detection of dark matter using a multi-ton liquid xenon time projection chamber at its core.
Abstract: DARk matter WImp search with liquid xenoN (DARWIN(2)) will be an experiment for the direct detection of dark matter using a multi-ton liquid xenon time projection chamber at its core. Its primary g ...
553 citations