scispace - formally typeset
Search or ask a question
Author

David A Armbruster

Bio: David A Armbruster is an academic researcher. The author has contributed to research in topics: Analyte & Detection limit. The author has an hindex of 1, co-authored 1 publications receiving 1326 citations.

Papers
More filters
01 Aug 2008
TL;DR: The Limit of Blank, Limit of Detection, and Limit of Quantitation are terms used to describe the smallest concentration of a measurand that can be reliably measured by an analytical procedure.
Abstract: * Limit of Blank (LoB), Limit of Detection (LoD), and Limit of Quantitation (LoQ) are terms used to describe the smallest concentration of a measurand that can be reliably measured by an analytical procedure. * LoB is the highest apparent analyte concentration expected to be found when replicates of a blank sample containing no analyte are tested. LoB = mean(blank) + 1.645(SD(blank)). * LoD is the lowest analyte concentration likely to be reliably distinguished from the LoB and at which detection is feasible. LoD is determined by utilising both the measured LoB and test replicates of a sample known to contain a low concentration of analyte. * LoD = LoB + 1.645(SD (low concentration sample)). * LoQ is the lowest concentration at which the analyte can not only be reliably detected but at which some predefined goals for bias and imprecision are met. The LoQ may be equivalent to the LoD or it could be at a much higher concentration.

1,656 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: The presented review provides information relating to the calculation of the limit of detection and limit of quantitation.
Abstract: The quality of an analytical method developed is always appraised in terms of suitability for its intended purpose, recovery, requirement for standardization, sensitivity, analyte stability, ease of analysis, skill subset required, time and cost in that order. It is highly imperative to establish through a systematic process that the analytical method under question is acceptable for its intended purpose. Limit of detection (LOD) and limit of quantification (LOQ) are two important performance characteristics in method validation. LOD and LOQ are terms used to describe the smallest concentration of an analyte that can be reliably measured by an analytical procedure. There has often been a lack of agreement within the clinical laboratory field as to the terminology best suited to describe this parameter. Likewise, there have been various methods for estimating it. The presented review provides information relating to the calculation of the limit of detection and limit of quantitation. Brief information about differences in various regulatory agencies about these parameters is also presented here.

2,264 citations

Journal ArticleDOI
TL;DR: This basic guide will help to orient beginners and users of qPCR in the use of this powerful technique.
Abstract: Real time PCR (quantitative PCR, qPCR) is now a well-established method for the detection, quantification, and typing of different microbial agents in the areas of clinical and veterinary diagnostics and food safety. Although the concept of PCR is relatively simple, there are specific issues in qPCR that developers and users of this technology must bear in mind. These include the use of correct terminology and definitions, understanding of the principle of PCR, difficulties with interpretation and presentation of data, the limitations of qPCR in different areas of microbial diagnostics and parameters important for the description of qPCR performance. It is not our intention in this review to describe every single aspect of qPCR design, optimization, and validation; however, it is our hope that this basic guide will help to orient beginners and users of qPCR in the use of this powerful technique.

494 citations

Journal ArticleDOI
TL;DR: This review describes the analytical requirements for a robust clinical biomarker assay, including concepts of precision, trueness, specificity and analytical interference, and carryover, and introduces the clinical considerations of diagnostic accuracy, receiver operating characteristic analysis, positive and negative predictive values, and clinical utility.
Abstract: Tremendous efforts have been made over the past few decades to discover novel cancer biomarkers for use in clinical practice. However, a striking discrepancy exists between the effort directed toward biomarker discovery and the number of markers that make it into clinical practice. One of the confounding issues in translating a novel discovery into clinical practice is that quite often the scientists working on biomarker discovery have limited knowledge of the analytical, diagnostic, and regulatory requirements for a clinical assay. This review provides an introduction to such considerations with the aim of generating more extensive discussion for study design, assay performance, and regulatory approval in the process of translating new proteomic biomarkers from discovery into cancer diagnostics. We first describe the analytical requirements for a robust clinical biomarker assay, including concepts of precision, trueness, specificity and analytical interference, and carryover. We next introduce the clinical considerations of diagnostic accuracy, receiver operating characteristic analysis, positive and negative predictive values, and clinical utility. We finish the review by describing components of the FDA approval process for protein-based biomarkers, including classification of biomarker assays as medical devices, analytical and clinical performance requirements, and the approval process workflow. While we recognize that the road from biomarker discovery, validation, and regulatory approval to the translation into the clinical setting could be long and difficult, the reward for patients, clinicians and scientists could be rather significant.

357 citations

Journal ArticleDOI
TL;DR: This work presents methods to determine the limit of detection (LoD) and thelimit of quantification (LoQ) as applicable to qPCR, based on standard statistical methods as recommended by regulatory bodies adapted toqPCR and complemented with a novel approach to estimate the precision of LoD.

347 citations

Journal ArticleDOI
TL;DR: A literature search was performed using MEDLINE/PubMed and scientific congress databases using the terms ‘BRAF,’ ‘mutation, and ‘cancer/tumor.’ These results were filtered to include diagnostic tests for determining BRAF mutation status as mentioned in this paper.

290 citations