D
Dieter Schardt
Researcher at GSI Helmholtz Centre for Heavy Ion Research
Publications - 80
Citations - 4188
Dieter Schardt is an academic researcher from GSI Helmholtz Centre for Heavy Ion Research. The author has contributed to research in topics: Ion beam & Beam (structure). The author has an hindex of 29, co-authored 80 publications receiving 3915 citations.
Papers
More filters
Journal ArticleDOI
The GSI projectile fragment separator (FRS): A Versatile magnetic system for relativistic heavy ions
H. Geissel,P. Armbruster,K.-H. Behr,A. Brünle,K. Burkard,M. Chen,H. Folger,B. Franczak,H. Keller,O. Klepper,B. Langenbeck,F. Nickel,E. Pfeng,M. Pfützner,E. Roeckl,K. P. Rykaczewski,I. Schall,Dieter Schardt,C. Scheidenberger,K.-H. Schmidt,A. Schröter,Th. Schwab,K. Sümmerer,Max Weber,G. Münzenberg,T. Brohm,H.-G. Clerc,Michael Fauerbach,J.-J. Gaimard,A. Grewe,E. Hanelt,B. Knödler,M. Steiner,Burkart Voss,J. Weckenmann,C. Ziegler,A. Magel,Hermann Wollnik,J.P. Dufour,Yoshitaka Fujita,D.J. Vieira,B. M. Sherrill +41 more
TL;DR: The projectile fragment separator FRS designed for research and applied studies with relativistic heavy ions was installed at GSI as a part of the new high-energy SIS/ESR accelerator facility as mentioned in this paper.
Journal ArticleDOI
Heavy-ion tumor therapy: Physical and radiobiological benefits
TL;DR: Results of clinical phase I-II trials provide evidence that carbon-ion radiotherapy might be beneficial in several tumor entities, and the progress in heavy-ion therapy is reviewed, including physical and technical developments, radiobiological studiesmore and models, as well as radiooncological studies.
Journal ArticleDOI
Treatment planning for heavy-ion radiotherapy: physical beam model and dose optimization.
TL;DR: A novel code system, TRiP, dedicated to the planning of radiotherapy with energetic ions, in particular 12C, designed to cooperate with three-dimensional active dose shaping devices like the GSI raster scan system is described.
Patent
Ion beam therapy system and a method for operating the system
Thomas Haberer,Michael Kramer,Gerhard Kraft,Wilma Kraft-Weyrather,Dieter Schardt,Michael Scholz,Ulrich Weber,Aleksiy Dolinski,Hartmut Eickhoff,Bernhard Franczak,Udo Krause,Jürgen Dr. Klabunde,Dahl Ludwig,Marius Pavlovic,Ulrich Ratzinger,Bernhard Schlitt,Joerg Dr Pawelke,Rainer Hinz,Wolfgang Enghardt +18 more
TL;DR: In this article, an ion beam therapy system comprising a plurality of separate patient treatment stations, a source of ions, an accelerator system for accelerating ions as a beam and a gantry transport system for directing the ion beam from the accelerator to the treatment stations is presented.
Journal ArticleDOI
Target motion tracking with a scanned particle beam
TL;DR: The motion tracking system successfully preserved dose distributions delivered to moving targets and maintained target conformity in order to mitigate the impact of respiratory motion.