scispace - formally typeset
Search or ask a question
Author

Dirk H. J. Poot

Bio: Dirk H. J. Poot is an academic researcher from Erasmus University Rotterdam. The author has contributed to research in topics: Medicine & Image registration. The author has an hindex of 22, co-authored 94 publications receiving 1888 citations. Previous affiliations of Dirk H. J. Poot include Delft University of Technology & Erasmus University Medical Center.


Papers
More filters
Journal ArticleDOI
TL;DR: The diffusion kurtosis imaging model provides a b‐value‐independent estimation of the widely used diffusion tensor parameters as demonstrated with diffusion‐weighted rat data, which was acquired with eight different b‐values, uniformly distributed in a range of [0,2800 sec/mm2].
Abstract: With diffusion tensor imaging, the diffusion of water molecules through brain structures is quantified by parameters, which are estimated assuming monoexponential diffusion-weighted signal attenuation. The estimated diffusion parameters, however, depend on the diffusion weighting strength, the b-value, which hampers the interpretation and comparison of various diffusion tensor imaging studies. In this study, a likelihood ratio test is used to show that the diffusion kurtosis imaging model provides a more accurate parameterization of both the Gaussian and non-Gaussian diffusion component compared with diffusion tensor imaging. As a result, the diffusion kurtosis imaging model provides a b-value-independent estimation of the widely used diffusion tensor parameters as demonstrated with diffusion-weighted rat data, which was acquired with eight different b-values, uniformly distributed in a range of [0,2800 sec/mm(2)]. In addition, the diffusion parameter values are significantly increased in comparison to the values estimated with the diffusion tensor imaging model in all major rat brain structures. As incorrectly assuming additive Gaussian noise on the diffusion-weighted data will result in an overestimated degree of non-Gaussian diffusion and a b-value-dependent underestimation of diffusivity measures, a Rician noise model was used in this study.

203 citations

Journal ArticleDOI
TL;DR: The results show that super‐resolution reconstruction can indeed improve the resolution, signal‐to‐noise ratio and acquisition time trade‐offs compared with direct high‐resolution acquisition.
Abstract: Improving the resolution in magnetic resonance imaging comes at the cost of either lower signal-to-noise ratio, longer acquisition time or both. This study investigates whether so-called super-resolution reconstruction methods can increase the resolution in the slice selection direction and, as such, are a viable alternative to direct high-resolution acquisition in terms of the signal-to-noise ratio and acquisition time trade-offs. The performance of six super-resolution reconstruction methods and direct high-resolution acquisitions was compared with respect to these trade-offs. The methods are based on iterative back-projection, algebraic reconstruction, and regularized least squares. The algorithms were applied to low-resolution data sets within which the images were rotated relative to each other. Quantitative experiments involved a computational phantom and a physical phantom containing structures of known dimensions. To visually validate the quantitative evaluations, qualitative experiments were performed, in which images of three different subjects (a phantom, an ex vivo rat knee, and a postmortem mouse) were acquired with different magnetic resonance imaging scanners. The results show that super-resolution reconstruction can indeed improve the resolution, signal-to-noise ratio and acquisition time trade-offs compared with direct high-resolution acquisition.

198 citations

Journal ArticleDOI
TL;DR: The precision with which the kurtosis parameters can be estimated, increases substantially by optimizing the gradient settings, and the gradient directions and the strengths of the diffusion-weighted MR images are optimized by minimizing the Crame¿r-Rao lower bound of DKI parameters.
Abstract: Diffusion kurtosis imaging (DKI) is a new magnetic resonance imaging (MRI) model that describes the non-Gaussian diffusion behavior in tissues. It has recently been shown that DKI parameters, such as the radial or axial kurtosis, are more sensitive to brain physiology changes than the well-known diffusion tensor imaging (DTI) parameters in several white and gray matter structures. In order to estimate either DTI or DKI parameters with maximum precision, the diffusion weighting gradient settings that are applied during the acquisition need to be optimized. Indeed, it has been shown previously that optimizing the set of diffusion weighting gradient settings can have a significant effect on the precision with which DTI parameters can be estimated. In this paper, we focus on the optimization of DKI gradients settings. Commonly, DKI data are acquired using a standard set of diffusion weighting gradients with fixed directions and with regularly spaced gradient strengths. In this paper, we show that such gradient settings are suboptimal with respect to the precision with which DKI parameters can be estimated. Furthermore, the gradient directions and the strengths of the diffusion-weighted MR images are optimized by minimizing the Crame?r-Rao lower bound of DKI parameters. The impact of the optimized gradient settings is evaluated, both on simulated as well as experimentally recorded datasets. It is shown that the precision with which the kurtosis parameters can be estimated, increases substantially by optimizing the gradient settings.

190 citations

Journal ArticleDOI
TL;DR: In this paper, a histogram-based noise variance estimation method based on the maximum likelihood (ML) principle is presented. But it requires user interaction and/or multiple (perfectly aligned) images.
Abstract: Estimation of the noise variance of a magnetic resonance (MR) image is important for various post-processing tasks. In the literature, various methods for noise variance estimation from MR images are available, most of which however require user interaction and/or multiple (perfectly aligned) images. In this paper, we focus on automatic histogram-based noise variance estimation techniques. Previously described methods are reviewed and a new method based on the maximum likelihood (ML) principle is presented. Using Monte Carlo simulation experiments as well as experimental MR data sets, the noise variance estimation methods are compared in terms of the root mean squared error (RMSE). The results show that the newly proposed method is superior in terms of the RMSE.

166 citations

Journal ArticleDOI
TL;DR: The groupwise registration method with a similarity measure based on PCA is the preferred technique for compensating misalignments in qMRI.

125 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: The generalized form of context-dependent PPI approach has increased flexibility of statistical modeling, and potentially improves model fit, specificity to true negative findings, and sensitivity to true positive findings.

1,148 citations

Journal ArticleDOI
TL;DR: A post-processing technique for fast denoising of diffusion-weighted MR images is introduced and it is demonstrated that the technique suppresses local signal fluctuations that solely originate from thermal noise rather than from other sources such as anatomical detail.

1,110 citations

Journal ArticleDOI
TL;DR: It is argued that the diffusional kurtosis is sensitive to diffusional heterogeneity and suggested that DKI may be useful for investigating ischemic stroke and neuropathologies, such as Alzheimer's disease and schizophrenia.
Abstract: Quantification of non-Gaussianity for water diffusion in brain by means of diffusional kurtosis imaging (DKI) is reviewed. Diffusional non-Gaussianity is a consequence of tissue structure that creates diffusion barriers and compartments. The degree of non-Gaussianity is conveniently quantified by the diffusional kurtosis and derivative metrics, such as the mean, axial, and radial kurtoses. DKI is a diffusion-weighted MRI technique that allows the diffusional kurtosis to be estimated with clinical scanners using standard diffusion-weighted pulse sequences and relatively modest acquisition times. DKI is an extension of the widely used diffusion tensor imaging method, but requires the use of at least 3 b-values and 15 diffusion directions. This review discusses the underlying theory of DKI as well as practical considerations related to data acquisition and post-processing. It is argued that the diffusional kurtosis is sensitive to diffusional heterogeneity and suggested that DKI may be useful for investigating ischemic stroke and neuropathologies, such as Alzheimer’s disease and schizophrenia.

1,056 citations

Journal ArticleDOI
TL;DR: The aim of this study is to incorporate support for multi-shell data into the CSD approach as well as to exploit the unique b-value dependencies of the different tissue types to estimate a multi-tissue ODF.

1,015 citations

Journal ArticleDOI
TL;DR: In this article, the authors provide a short overview of recent advances and some associated challenges in machine learning applied to medical image processing and image analysis, and provide a starting point for people interested in experimenting and perhaps contributing to the field of machine learning for medical imaging.
Abstract: What has happened in machine learning lately, and what does it mean for the future of medical image analysis? Machine learning has witnessed a tremendous amount of attention over the last few years. The current boom started around 2009 when so-called deep artificial neural networks began outperforming other established models on a number of important benchmarks. Deep neural networks are now the state-of-the-art machine learning models across a variety of areas, from image analysis to natural language processing, and widely deployed in academia and industry. These developments have a huge potential for medical imaging technology, medical data analysis, medical diagnostics and healthcare in general, slowly being realized. We provide a short overview of recent advances and some associated challenges in machine learning applied to medical image processing and image analysis. As this has become a very broad and fast expanding field we will not survey the entire landscape of applications, but put particular focus on deep learning in MRI. Our aim is threefold: (i) give a brief introduction to deep learning with pointers to core references; (ii) indicate how deep learning has been applied to the entire MRI processing chain, from acquisition to image retrieval, from segmentation to disease prediction; (iii) provide a starting point for people interested in experimenting and perhaps contributing to the field of machine learning for medical imaging by pointing out good educational resources, state-of-the-art open-source code, and interesting sources of data and problems related medical imaging.

991 citations