scispace - formally typeset
Search or ask a question

Showing papers by "Dominicus Danardono Dwi Prija Tjahjana published in 2018"


Proceedings ArticleDOI
09 Feb 2018
TL;DR: In this article, the effect of Omni-Directional Guide Vane (ODGV) on the performance of a cross-flow wind turbine was evaluated in a wind tunnel experiment.
Abstract: Vertical axis wind turbine like cross-flow rotor have some advantage there are, high self-starting torque, low noise, and high stability; so, it can be installed in the urban area to produce electricity. But, the urban area has poor wind condition, so the cross-flow rotor needs a guide vane to increase its performance. The aim of this study is to determine experimentally the effect of Omni-Directional Guide Vane (ODGV) on the performance of a cross-flow wind turbine. Wind tunnel experiment has been carried out for various configurations. The ODGV was placed around the cross-flow rotor in order to increase ambient wind environment of the wind turbine. The maximum power coefficient is obtained as Cpmax = 0.125 at 60° wind direction. It was 21.46% higher compared to cross-flow wind turbine without ODGV. This result showed that the ODGV able to increase the performance of the cross-flow wind turbine.

11 citations


Proceedings ArticleDOI
09 Feb 2018
TL;DR: In this article, the authors show that with the addition of fin can improve the performance of wind turbine Savonius 11%, and by using the diameter of 115 mm fin is able to provide maximum performance.
Abstract: The use of renewable energy in Indonesia is still low. Especially the use of wind energy. Wind turbine Savonius is one turbine that can work with low wind speed. However, Savonius wind turbines still have low efficiency. Therefore it is necessary to modify. Modifications by using the fin are expected to increase the positive drag force by creating a flow that can enter the overlap ratio of the gap. This research was conducted using experimental approach scheme. Parameters generated from the experiment include: power generator, power coefficient, torque coefficient. The experimental data will be collected by variation of fin area, horizontal finning, at wind speed 3 m/s - 4,85 m/s. Experimental results show that with the addition of fin can improve the performance of wind turbine Savonius 11%, and by using the diameter of 115 mm fin is able to provide maximum performance in wind turbine Savonius.

10 citations


Proceedings ArticleDOI
09 Feb 2018
TL;DR: In this paper, the effect of blades number on cross-flow wind turbine performance was investigated and the result showed that best performance on 16 blade number was achieved by the turbine at low wind speed on 2 -5m/s.
Abstract: Urban living is one of the areas with large electrical power consumption that requires a power supply that is more than rural areas. The number of multi-storey buildings such as offices, hotels and several other buildings that caused electricity power consumption in urban living is very high. Therefore, energy alternative is needed to replace the electricity power consumption from government. One of the utilization of renewable energy in accordance with these conditions is the installation of wind turbines. One type of wind turbine that is now widely studied is a crossflow wind turbines. Crossflow wind turbine is one of vertical axis wind turbine which has good self starting at low wind speed condition. Therefore, the turbine design parameter is necessary to know in order to improve turbine performance. One of wind turbine performance parameter is blades number. The main purpose of this research to investigate the effect of blades number on crossflow wind turbine performance. The design of turbine was 0.4 × 0.4 m2 tested by experimental method with configuration on three kinds of blades number were 8,16 and 20. The turbine investigated at low wind speed on 2 – 5 m/s. The result showed that best performance on 16 blade number.

10 citations


Proceedings ArticleDOI
09 Feb 2018
TL;DR: The workable way to improve pump performance is to redesign or modify the impellers of centrifugal pump to improved pump efficiency, reduce cross flow, reduce secondary incidence flows, and decrease backflow areas at impeller outlets.
Abstract: The workable way to improve pump performance is to redesign or modify the impellers of centrifugal pump. The purpose of impeller pump modification is to improve pump efficiency, reduce cross flow, reduce secondary incidence flows, and decrease backflow areas at impeller outlets. Number blades and splitter blades in the impeller are three. The outlet blade angle is 20°, and the rotating speed of impeller is 2400 rpm. The added splitter blades variations are 0.25, 0.375, and 0.5 of the original blade length. The splitter blade placements are on the outer side of the impeller. The addition of splitter blades on the outer side of the impeller with 0.5L increases the pump head until 22% and the pump has 38.66% hydraulic efficiency. The best efficiency point of water flow rate pump (Qbep) was 3.02 × 10−3 m3/s.

7 citations


Proceedings ArticleDOI
09 Feb 2018
TL;DR: In this article, the effect of the diameter ratio and the blade number on the performance of a cross-flow wind turbine was studied in two dimensional (2D) computational fluid dynamics (CFD) simulation method using the ANSYS-Fluent software.
Abstract: Cross flow turbine can be one of the alternative energies for regions with low wind speed. Collision between wind and the blades which happened two times caused the cross flow turbine to have high power coefficient. Some factors that influence the turbine power coefficient are diameter ratio and blade number. The objective of the research was to study the effect of the diameter ratio and the blade number to the cross flow wind turbine performance. The study was done in two dimensional (2D) computational fluid dynamics (CFD) simulation method using the ANSYS-Fluent software. The turbine diameter ratio were 0.58, 0.63, 0.68 and 0.73. The diameter ratio resulting in the highest power coefficient value was then simulated by varying the number of blades, namely 16, 20 and 24. Each variation was tested on the wind speed of 2 m/s and at the tip speed ratio (TSR) of 0.1 to 0.4 with the interval of 0.1. The wind turbine with the ratio diameter of 0.68 and the number of blades of 20 generated the highest power coefficient of 0.5 at the TSR of 0.3.Cross flow turbine can be one of the alternative energies for regions with low wind speed. Collision between wind and the blades which happened two times caused the cross flow turbine to have high power coefficient. Some factors that influence the turbine power coefficient are diameter ratio and blade number. The objective of the research was to study the effect of the diameter ratio and the blade number to the cross flow wind turbine performance. The study was done in two dimensional (2D) computational fluid dynamics (CFD) simulation method using the ANSYS-Fluent software. The turbine diameter ratio were 0.58, 0.63, 0.68 and 0.73. The diameter ratio resulting in the highest power coefficient value was then simulated by varying the number of blades, namely 16, 20 and 24. Each variation was tested on the wind speed of 2 m/s and at the tip speed ratio (TSR) of 0.1 to 0.4 with the interval of 0.1. The wind turbine with the ratio diameter of 0.68 and the number of blades of 20 generated the highest power coef...

7 citations


Journal ArticleDOI
01 Mar 2018
TL;DR: In this paper, the authors compared the pressure drop generated under various gap sizes in the effective regions of the MR valve and compared the results of the simulations are compared to different gap sizes and discussed.
Abstract: Magnetorheological (MR) valve is one of the key components in regulating the magnetorheological (MR) fluid flow in MR devices. Due to MR properties enabling magnetic modifications, many MR valve designs have been introduced and are widely utilized in MR devices. Serpentine MR valve has a potential in improving the MR devices performance, whereby using this method it can help to increase the effective region of the valve. Thus, this article is comparing the pressure drops generated under various gap sizes in the effective regions of MR valve. Three different gap sizes are considered for this study. To provide a fair comparison, several parameters are fixed; the size of the MR valves, the number of coil turns and the power consumption. In order to demonstrate the MR valve performance, the pressure drops are calculated based on the mathematical equations derived from MR valve models and the magnetic fields derived from Finite Element Method Magnetics (FEMM) software. The results of the simulations are compared to various gap sizes and, discussed.

4 citations


Proceedings ArticleDOI
09 Feb 2018
TL;DR: A feasibility study of wind energy in urban area of Surakarta was done by using Weibull distribution as discussed by the authors, which showed that in five years the city had mean energy density (ED) of 139.43 W/m 2, yearly energy available (EI) of 1221.4 kWh/m2/year, the most frequent wind velocity (VFmax) of 4.79
Abstract: Wind energy is one of the promising energy resource in urban area that has not been deeply explored in Indonesia. Generally the wind velocity in Indonesia is relatively low, however on the roof top of the high rise building in urban area the wind velocity is high enough to be converted for supporting the energy needs of the building. In this research a feasibility study of wind energy in urban area of Surakarta was done. The analysis of the wind energy potential on the height of 50 m was done by using Weibull distribution. The wind data based on the daily wind speed taken from 2011-2015. From the result of the wind speed analysis, a wind map in Surakarta was developed for helping to determine the places that have good potential in wind energy. The result showed that in five years the city of Surakarta had mean energy density (ED) of 139.43 W/m2, yearly energy available (EI) of 1221.4 kWh/m2/year, the most frequent wind velocity (VFmax) of 4.79 m/s, and the velocity contributing the maximum energy (VEmax) of 6.97 m/s. The direction of the wind was mostly from south, with frequency of 38%. The south and west area of the city had higher wind velocity than the other parts of the city. Also in those areas there are many high rise buildings, which are appropriate for installation of small wind turbine on the roof top (building mounted wind turbine/ BMWT).

4 citations


Proceedings ArticleDOI
09 Feb 2018
TL;DR: In this article, the best configuration between guide vanes and cross flow vertical axis wind turbine with variation of several parameters including tilt angle and the number of turbine and guide vane blades was investigated.
Abstract: The main purpose of this study is to investigate the best configuration between guide vanes and cross flow vertical axis wind turbine with variation of several parameters including guide vanes tilt angle and the number of turbine and guide vane blades. The experimental test were conducted under various wind speed and directions for testing cross flow wind turbine, consisted of 8, 12 and 16 blades. Two types of guide vane were developed in this study, employing 20° and 60° tilt angle. Both of the two types of guide vane had three variations of blade numbers which had same blade numbers variations as the turbines. The result showed that the configurations between 60° guide vane with 16 blade numbers and turbine with 16 blade numbers had the best configurations. The result also showed that for certain configuration, guide vane was able to increase the power generated by the turbine significantly by 271.39% compared to the baseline configuration without using of guide vane.

4 citations


Journal ArticleDOI
01 Jan 2018
TL;DR: In this paper, a cross-flow wind turbine with a guide vane attached at the right position had a higher coefficient of power than cross flow turbine without guide-vane.
Abstract: The purpose of this experiment is to know the influence of a single guide vane position and angle to the performance of a cross-flow wind turbine. The cross-flow wind turbine was positioned at the discharge outlet of a cooling tower model to harness the discharged wind for electricity generation. A guide vane was used to enhance the rotational speed of the turbines for power augmentation. Various position and angle of attack of the guide vane were tested in this experiment. To avoid negative impact on the performance of the cooling tower fan and to optimize the wind turbine performance, the turbine position on the discharge wind stream was also studied. The result showed that cross-flow wind turbine with a guide vane attached at the right position had a higher coefficient of power than cross flow turbine without guide vane. A crossflow wind turbine with the guide vane at the position of 150 mm from the center and 30° angles had the highest coefficient of power of 0.49. Comparing to the wind turbine without guide vane, the coefficient of power of the cross-flow wind turbine was increased about 84.3%.

3 citations


Proceedings ArticleDOI
09 Feb 2018
TL;DR: In this paper, the authors found that the configurations between 0.68 diameter ratio and 20 blade numbers is the best configuration that has power coefficient of 0.049 and moment coefficient of 1.185, while the variations of number of blades used was 16, 20 and 24.
Abstract: Cross-flow wind turbine is one of the alternative energy harvester for low wind speeds area. Several factors that influence the power coefficient of cross-flow wind turbine are the diameter ratio of blades and the number of blades. The aim of this study is to find out the influence of the number of blades and the diameter ratio on the performance of cross-flow wind turbine and to find out the best configuration between number of blades and diameter ratio of the turbine. The experimental test were conducted under several variation including diameter ratio between outer and inner diameter of the turbine and number of blades. The variation of turbine diameter ratio between inner and outer diameter consisted of 0.58, 0.63, 0.68 and 0.73 while the variations of the number of blades used was 16, 20 and 24. The experimental test were conducted under certain wind speed which are 3m/s until 4 m/s. The result showed that the configurations between 0.68 diameter ratio and 20 blade numbers is the best configurations that has power coefficient of 0.049 and moment coefficient of 0.185.Cross-flow wind turbine is one of the alternative energy harvester for low wind speeds area. Several factors that influence the power coefficient of cross-flow wind turbine are the diameter ratio of blades and the number of blades. The aim of this study is to find out the influence of the number of blades and the diameter ratio on the performance of cross-flow wind turbine and to find out the best configuration between number of blades and diameter ratio of the turbine. The experimental test were conducted under several variation including diameter ratio between outer and inner diameter of the turbine and number of blades. The variation of turbine diameter ratio between inner and outer diameter consisted of 0.58, 0.63, 0.68 and 0.73 while the variations of the number of blades used was 16, 20 and 24. The experimental test were conducted under certain wind speed which are 3m/s until 4 m/s. The result showed that the configurations between 0.68 diameter ratio and 20 blade numbers is the best configurations ...

1 citations


Proceedings ArticleDOI
09 Feb 2018
TL;DR: In this paper, the authors present experimental test results of separator and shift angle influence on crossflow vertical axis wind turbine with 3-and 2-stage crossflow with the shift angle.
Abstract: This paper present experimental test results of separator and shift angle influence on Crossflow vertical axis wind turbine. Modification by using a separator and shift angle is expected to improve the thrust on the blade so as to improve the efficiency. The design of the wind turbine is tested at different wind speeds. There are 2 variations of crossflow turbine design which will be analyzed using an experimental test scheme that is, 3 stage crossflow and 2 stage crossflow with the shift angle. Maximum power coefficient obtained as Cpmax = 0.13 at wind speed 4.05 m/s for 1 separator and Cpmax = 0.12 for 12° shear angle of wind speed 4.05 m/s. In this study, power characteristics of the crossflow rotor with separator and shift angle have been tested. The experimental data was collected by variation of 2 separator and shift angle 0°, 6°, 12° and wind speed 3.01 – 4.85 m/s.This paper present experimental test results of separator and shift angle influence on Crossflow vertical axis wind turbine. Modification by using a separator and shift angle is expected to improve the thrust on the blade so as to improve the efficiency. The design of the wind turbine is tested at different wind speeds. There are 2 variations of crossflow turbine design which will be analyzed using an experimental test scheme that is, 3 stage crossflow and 2 stage crossflow with the shift angle. Maximum power coefficient obtained as Cpmax = 0.13 at wind speed 4.05 m/s for 1 separator and Cpmax = 0.12 for 12° shear angle of wind speed 4.05 m/s. In this study, power characteristics of the crossflow rotor with separator and shift angle have been tested. The experimental data was collected by variation of 2 separator and shift angle 0°, 6°, 12° and wind speed 3.01 – 4.85 m/s.