scispace - formally typeset
Search or ask a question
Author

Dominik Szczerba

Bio: Dominik Szczerba is an academic researcher from ETH Zurich. The author has contributed to research in topics: Deuterium & Electron. The author has an hindex of 15, co-authored 51 publications receiving 2108 citations. Previous affiliations of Dominik Szczerba include University of Silesia in Katowice.


Papers
More filters
Journal ArticleDOI
TL;DR: All tissues and organs were reconstructed as three-dimensional unstructured triangulated surface objects, yielding high precision images of individual features of the body, which greatly enhances the meshing flexibility and the accuracy in comparison with the traditional voxel-based representation of anatomical models.
Abstract: The objective of this study was to develop anatomically correct whole body human models of an adult male (34 years old), an adult female (26 years old) and two children (an 11-year-old girl and a six-year-old boy) for the optimized evaluation of electromagnetic exposure. These four models are referred to as the Virtual Family. They are based on high resolution magnetic resonance (MR) images of healthy volunteers. More than 80 different tissue types were distinguished during the segmentation. To improve the accuracy and the effectiveness of the segmentation, a novel semi-automated tool was used to analyze and segment the data. All tissues and organs were reconstructed as three-dimensional (3D) unstructured triangulated surface objects, yielding high precision images of individual features of the body. This greatly enhances the meshing flexibility and the accuracy with respect to thin tissue layers and small organs in comparison with the traditional voxel-based representation of anatomical models. Conformal computational techniques were also applied. The techniques and tools developed in this study can be used to more effectively develop future models and further improve the accuracy of the models for various applications. For research purposes, the four models are provided for free to the scientific community.

1,347 citations

Journal ArticleDOI
TL;DR: The research and development performed to obtain anatomical models that meet the requirements necessary for medical implant safety assessment applications are described, including implementation of quality control procedures, re-segmentation at higher resolution, more-consistent tissue assignments, enhanced surface processing and numerous anatomical refinements.
Abstract: The Virtual Family computational whole-body anatomical human models were originally developed for electromagnetic (EM) exposure evaluations, in particular to study how absorption of radiofrequency radiation from external sources depends on anatomy. However, the models immediately garnered much broader interest and are now applied by over 300 research groups, many from medical applications research fields. In a first step, the Virtual Family was expanded to the Virtual Population to provide considerably broader population coverage with the inclusion of models of both sexes ranging in age from 5 to 84 years old. Although these models have proven to be invaluable for EM dosimetry, it became evident that significantly enhanced models are needed for reliable effectiveness and safety evaluations of diagnostic and therapeutic applications, including medical implants safety. This paper describes the research and development performed to obtain anatomical models that meet the requirements necessary for medical implant safety assessment applications. These include implementation of quality control procedures, re-segmentation at higher resolution, more-consistent tissue assignments, enhanced surface processing and numerous anatomical refinements. Several tools were developed to enhance the functionality of the models, including discretization tools, posing tools to expand the posture space covered, and multiple morphing tools, e.g., to develop pathological models or variations of existing ones. A comprehensive tissue properties database was compiled to complement the library of models. The results are a set of anatomically independent, accurate, and detailed models with smooth, yet feature-rich and topologically conforming surfaces. The models are therefore suited for the creation of unstructured meshes, and the possible applications of the models are extended to a wider range of solvers and physics. The impact of these improvements is shown for the MRI exposure of an adult woman with an orthopedic spinal implant. Future developments include the functionalization of the models for specific physical and physiological modeling tasks.

355 citations

Journal ArticleDOI
TL;DR: In this paper, the first measurement of spin correlation parameters in quasifree electron scattering from vector-polarized deuterium was reported, where polarized electrons were injected into an electron storage ring at a beam energy of 720 MeV.
Abstract: We report on the first measurement of spin-correlation parameters in quasifree electron scattering from vector-polarized deuterium. Polarized electrons were injected into an electron storage ring at a beam energy of 720 MeV. A Siberian snake was employed to preserve longitudinal polarization at the interaction point. Vector-polarized deuterium was produced by an atomic beam source and injected into an open-ended cylindrical cell, internal to the electron storage ring. The spin correlation parameter A[sup V] [sub ed] was measured for the reaction [sup 2] H [rvec e] ([rvec e], e [prime] n) p at a four-momentum transfer squared of 0.21 (GeV/c)[sup 2] from which a value for the charge form factor of the neutron was extracted. [copyright] [ital 1999] [ital The American Physical Society]

147 citations

Journal ArticleDOI
TL;DR: The model, consisting of steady-state flow and a simple mechanistic tissue response, successfully predicts bifurcation formation and micro-vessel separation in a porous cellular medium and opens new modelling possibilities in computational studies of the cellular transport involved in micro-vascular growth.

34 citations

Journal ArticleDOI
TL;DR: In this article, numerical simulation of oscillatory flow through the abdominal aortic bifurcation is performed with a finite volume and a finite element method, two approaches with significant differences in their discretization strategy, treatment of boundary conditions and other numerical aspects.
Abstract: Cardiovascular diseases are one of the major causes of long-term morbidity and mortality in human beings. The nearly epidemic increase in prevalence of such diseases poses a serious threat to public health and calls for efficient methods of diagnosis and treatment. Non-invasive diagnostic procedures such as MRI are often used in this context; however, these are limited in terms of spatial and temporal resolution and do not provide information on time-dependent pressures and wall shear stresses—key quantities considered to be partially responsible for the formation and development of related pathologies. The present study is concerned with the numerical simulation of oscillatory flow through the abdominal aortic bifurcation. Computational fluid dynamics simulation of oscillatory flow in a branched geometry at high Reynolds numbers poses considerable challenges. The present study reports a detailed comparison of simulations performed with a finite volume and a finite element method, two approaches with significant differences in their discretization strategy, treatment of boundary conditions and other numerical aspects. Both solvers were parallelized, using loop parallelization of the BiCGStab linear solver for the finite volume and domain decomposition based on the Schur complement method for the finite element technique. The experience gained with these two approaches for the solution of flow in a bifurcation forms the focus of this study. Although similar results were obtained for both methods, the computation time required for convergence was found to be significantly smaller for the finite element approach. Copyright © 2010 John Wiley & Sons, Ltd.

31 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: All tissues and organs were reconstructed as three-dimensional unstructured triangulated surface objects, yielding high precision images of individual features of the body, which greatly enhances the meshing flexibility and the accuracy in comparison with the traditional voxel-based representation of anatomical models.
Abstract: The objective of this study was to develop anatomically correct whole body human models of an adult male (34 years old), an adult female (26 years old) and two children (an 11-year-old girl and a six-year-old boy) for the optimized evaluation of electromagnetic exposure. These four models are referred to as the Virtual Family. They are based on high resolution magnetic resonance (MR) images of healthy volunteers. More than 80 different tissue types were distinguished during the segmentation. To improve the accuracy and the effectiveness of the segmentation, a novel semi-automated tool was used to analyze and segment the data. All tissues and organs were reconstructed as three-dimensional (3D) unstructured triangulated surface objects, yielding high precision images of individual features of the body. This greatly enhances the meshing flexibility and the accuracy with respect to thin tissue layers and small organs in comparison with the traditional voxel-based representation of anatomical models. Conformal computational techniques were also applied. The techniques and tools developed in this study can be used to more effectively develop future models and further improve the accuracy of the models for various applications. For research purposes, the four models are provided for free to the scientific community.

1,347 citations

Journal ArticleDOI
TL;DR: This review covers technical aspects of tES, as well as applications like exploration of brain physiology, modelling approaches, tES in cognitive neurosciences, and interventional approaches to help the reader to appropriately design and conduct studies involving these brain stimulation techniques.

942 citations

Journal ArticleDOI
TL;DR: In this paper, the authors provide an overview of multiscale modelling focusing on the growth phase of tumours and bypassing the initial stage of tumourigenesis, and limit the scope further by considering models of tumor progression that do not distinguish tumour cells by their age and do not consider immune system interactions nor do they describe models of therapy.
Abstract: Despite major scientific, medical and technological advances over the last few decades, a cure for cancer remains elusive. The disease initiation is complex, and including initiation and avascular growth, onset of hypoxia and acidosis due to accumulation of cells beyond normal physiological conditions, inducement of angiogenesis from the surrounding vasculature, tumour vascularization and further growth, and invasion of surrounding tissue and metastasis. Although the focus historically has been to study these events through experimental and clinical observations, mathematical modelling and simulation that enable analysis at multiple time and spatial scales have also complemented these efforts. Here, we provide an overview of this multiscale modelling focusing on the growth phase of tumours and bypassing the initial stage of tumourigenesis. While we briefly review discrete modelling, our focus is on the continuum approach. We limit the scope further by considering models of tumour progression that do not distinguish tumour cells by their age. We also do not consider immune system interactions nor do we describe models of therapy. We do discuss hybrid-modelling frameworks, where the tumour tissue is modelled using both discrete (cell-scale) and continuum (tumour-scale) elements, thus connecting the micrometre to the centimetre tumour scale. We review recent examples that incorporate experimental data into model parameters. We show that recent mathematical modelling predicts that transport limitations of cell nutrients, oxygen and growth factors may result in cell death that leads to morphological instability, providing a mechanism for invasion via tumour fingering and fragmentation. These conditions induce selection pressure for cell survivability, and may lead to additional genetic mutations. Mathematical modelling further shows that parameters that control the tumour mass shape also control its ability to invade. Thus, tumour morphology may serve as a predictor of invasiveness and treatment prognosis.

541 citations

Journal ArticleDOI
TL;DR: How various anatomical features systematically shape the electric field distribution in the brain during tDCS is shown, namely the thicknesses of the cerebrospinal fluid and the skull, the gyral depth and the distance to the anode and cathode.

495 citations

Journal ArticleDOI
TL;DR: The research and development performed to obtain anatomical models that meet the requirements necessary for medical implant safety assessment applications are described, including implementation of quality control procedures, re-segmentation at higher resolution, more-consistent tissue assignments, enhanced surface processing and numerous anatomical refinements.
Abstract: The Virtual Family computational whole-body anatomical human models were originally developed for electromagnetic (EM) exposure evaluations, in particular to study how absorption of radiofrequency radiation from external sources depends on anatomy. However, the models immediately garnered much broader interest and are now applied by over 300 research groups, many from medical applications research fields. In a first step, the Virtual Family was expanded to the Virtual Population to provide considerably broader population coverage with the inclusion of models of both sexes ranging in age from 5 to 84 years old. Although these models have proven to be invaluable for EM dosimetry, it became evident that significantly enhanced models are needed for reliable effectiveness and safety evaluations of diagnostic and therapeutic applications, including medical implants safety. This paper describes the research and development performed to obtain anatomical models that meet the requirements necessary for medical implant safety assessment applications. These include implementation of quality control procedures, re-segmentation at higher resolution, more-consistent tissue assignments, enhanced surface processing and numerous anatomical refinements. Several tools were developed to enhance the functionality of the models, including discretization tools, posing tools to expand the posture space covered, and multiple morphing tools, e.g., to develop pathological models or variations of existing ones. A comprehensive tissue properties database was compiled to complement the library of models. The results are a set of anatomically independent, accurate, and detailed models with smooth, yet feature-rich and topologically conforming surfaces. The models are therefore suited for the creation of unstructured meshes, and the possible applications of the models are extended to a wider range of solvers and physics. The impact of these improvements is shown for the MRI exposure of an adult woman with an orthopedic spinal implant. Future developments include the functionalization of the models for specific physical and physiological modeling tasks.

355 citations