scispace - formally typeset
Search or ask a question
Author

Farhad Iranpour

Bio: Farhad Iranpour is an academic researcher from Imperial College London. The author has contributed to research in topics: Arthroplasty & Patella. The author has an hindex of 24, co-authored 55 publications receiving 1655 citations. Previous affiliations of Farhad Iranpour include Royal Free London NHS Foundation Trust & Barnet Hospital.


Papers
More filters
Journal ArticleDOI
TL;DR: This review aims at classifying the different options to frontally align TKA implants, comparing their safety and efficacy with the one from MA TKAs, and answering the following questions: does alternative techniques to position TKA improve functional outcomes of TKA and is there any pathoanatomy not suitable for kinematic implantation of a TKA?
Abstract: In spite of improvements in implant designs and surgical precision, functional outcomes of mechanically aligned total knee arthroplasty (MA TKA) have plateaued. This suggests probable technical intrinsic limitations that few alternate more anatomical recently promoted surgical techniques are trying to solve. This review aims at (1) classifying the different options to frontally align TKA implants, (2) at comparing their safety and efficacy with the one from MA TKAs, therefore answering the following questions: does alternative techniques to position TKA improve functional outcomes of TKA (question 1)? Is there any pathoanatomy not suitable for kinematic implantation of a TKA (question 2)? A systematic review of the existing literature utilizing PubMed and Google Scholar search engines was performed in February 2017. Only studies published in peer-reviewed journals over the last ten years in either English or French were reviewed. We identified 569 reports, of which 13 met our eligibility criteria. Four alternative techniques to position a TKA are challenging the traditional MA technique: anatomic (AA), adjusted mechanical (aMA), kinematic (KA), and restricted kinematic (rKA) alignment techniques. Regarding osteoarthritic patients with slight to mid constitutional knee frontal deformity, the KA technique enables a faster recovery and generally generates higher functional TKA outcomes than the MA technique. Kinematic alignment for TKA is a new attractive technique for TKA at early to mid-term, but need longer follow-up in order to assess its true value. It is probable that some forms of pathoanatomy might affect longer-term clinical outcomes of KA TKA and make the rKA technique or additional surgical corrections (realignment osteotomy, retinacular ligament reconstruction etc.) relevant for this sub-group of patients. Longer follow-up is needed to define the best indication of each alternative surgical technique for TKA. Level I for question 1 (systematic review of Level I studies), level 4 for question 2.

222 citations

Journal ArticleDOI
TL;DR: 3D-reconstructed images are sufficiently reliable to enable reporting of the position and orientation of the components in a poorly functioning TKR with concerns over component positioning, and are recommend 3D-CT as the investigation of choice.
Abstract: We studied the intra- and interobserver reliability of measurements of the position of the components after total knee replacement (TKR) using a combination of radiographs and axial two-dimensional (2D) and three-dimensional (3D) reconstructed CT images to identify which method is best for this purpose. A total of 30 knees after primary TKR were assessed by two independent observers (an orthopaedic surgeon and a radiologist) using radiographs and CT scans. Plain radiographs were highly reliable at measuring the tibial slope, but showed wide variability for all other measurements; 2D-CT also showed wide variability. 3D-CT was highly reliable, even when measuring rotation of the femoral components, and significantly better than 2D-CT. Interobserver variability in the measurements on radiographs were good (intraclass correlation coefficient (ICC) 0.65 to 0.82), but rotational measurements on 2D-CT were poor (ICC 0.29). On 3D-CT they were near perfect (ICC 0.89 to 0.99), and significantly more reliable than 2D-CT (p < 0.001). 3D-reconstructed images are sufficiently reliable to enable reporting of the position and orientation of the components. Rotational measurements in particular should be performed on 3D-reconstructed CT images. When faced with a poorly functioning TKR with concerns over component positioning, we recommend 3D-CT as the investigation of choice.

169 citations

Journal ArticleDOI
TL;DR: Alignment of the knee when based on this anatomical axis was more reliable than either the posterior surfaces or any axis involving the tubercle which was the least reliable landmark in the region.
Abstract: The rotational alignment of the tibia is an unresolved issue in knee replacement. A poor functional outcome may be due to malrotation of the tibial component. Our aim was to find a reliable method for positioning the tibial component in knee replacement. CT scans of 19 knees were reconstructed in three dimensions and orientated vertically. An axial plane was identified 20 mm below the tibial spines. The centre of each tibial condyle was calculated from ten points taken round the condylar cortex. The tibial tubercle centre was also generated as the centre of the circle which best fitted eight points on the outside of the tubercle in an axial plane at the level of its most prominent point. The derived points were identified by three observers with errors of 0.6 mm to 1 mm. The medial and lateral tibial centres were constant features (radius 24 mm (SD 3), and 22 mm (SD 3), respectively). An anatomical axis was created perpendicular to the line joining these two points. The tubercle centre was found to be 20 mm (SD 7) lateral to the centre of the medial tibial condyle. Compared with this axis, an axis perpendicular to the posterior condylar axis was internally rotated by 6 degrees (SD 3). An axis based on the tibial tubercle and the tibial spines was also internally rotated by 5 degrees (sd 10). Alignment of the knee when based on this anatomical axis was more reliable than either the posterior surfaces or any axis involving the tubercle which was the least reliable landmark in the region.

140 citations

Journal ArticleDOI
TL;DR: SPECT/CT was very helpful in establishing the diagnosis and guiding subsequent management in patients with painful knees after TKA, particularly in patientswith patellofemoral problems and malpositioned or loose TKA.
Abstract: The purpose of our study was to evaluate the clinical value of hybrid SPECT/CT for the assessment of patients with painful total knee arthroplasty (TKA). Twenty-three painful knees in patients following primary TKA were assessed using Tc-99m-HDP-SPECT/CT. Rotational, sagittal and coronal position of the TKA was assessed on 3D-CT reconstructions. The level of the SPECT-tracer uptake (0-10) and its anatomical distribution was mapped using a validated localization scheme. Univariate analysis (Wilcoxon-Mann-Whitney, Spearmean`s-rho test, p < 0.05) was performed to identify any correlations between component position, tracer uptake and diagnosis. SPECT/CT imaging changed the suspected diagnosis and the proposed treatment in 19/23 (83%) knees. Progression of patellofemoral OA (n = 11), loosening of the tibial (n = 3) and loosening of the femoral component (n = 2) were identified as the leading causes of pain after TKA. Patients with externally rotated tibial trays showed higher tracer uptake in the medial patellar facet (p = 0.049) and in the femur (p = 0.051). Patients with knee pain due to patellofemoral OA showed significantly higher tracer uptake in the patella than others (p < 0.001). SPECT/CT was very helpful in establishing the diagnosis and guiding subsequent management in patients with painful knees after TKA, particularly in patients with patellofemoral problems and malpositioned or loose TKA.

101 citations

Journal ArticleDOI
TL;DR: In the natural and prosthetic knees the position, shape, and orientation of the trochlea groove are three of the key determinants of function and dysfunction, yet the rules governing these three features remain elusive as discussed by the authors.
Abstract: Background In the natural and prosthetic knees the position, shape, and orientation of the trochlea groove are three of the key determinants of function and dysfunction, yet the rules governing these three features remain elusive.

99 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: In the eight knees in which it was measured, the anterolateral ligament was isometric from 0° to 60° of flexion of the knee, then slackened when the knee flexed further to 90° and was lengthened by imposing tibial internal rotation.
Abstract: There have been differing descriptions of the anterolateral structures of the knee, and not all have been named or described clearly. The aim of this study was to provide a clear anatomical interpretation of these structures. We dissected 40 fresh-frozen cadaveric knees to view the relevant anatomy and identified a consistent structure in 33 knees (83%); we termed this the anterolateral ligament of the knee. This structure passes antero-distally from an attachment proximal and posterior to the lateral femoral epicondyle to the margin of the lateral tibial plateau, approximately midway between Gerdy’s tubercle and the head of the fibula. The ligament is superficial to the lateral (fibular) collateral ligament proximally, from which it is distinct, and separate from the capsule of the knee. In the eight knees in which it was measured, we observed that the ligament was isometric from 0° to 60° of flexion of the knee, then slackened when the knee flexed further to 90° and was lengthened by imposing tibial internal rotation. Cite this article: Bone Joint J 2014;96-B:325–31.

361 citations

01 Sep 2005
TL;DR: Three‐dimensional computed tomography represents an accurate tool to quantify the femoral head‐neck concavity providing a non‐invasive assessment of hips at risk of femoroacetabular impingement.
Abstract: Introduction and Aims: There is a relationship between the anatomy of the hip joint and the development of arthritis. A common cause of hip pain in the young adult that can lead to arthritis is acetabular dysplasia. More recently, femoroacetabular impingement has been described as another cause of hip pain. The purpose of our study was to evaluate the applicability of pelvic computed tomography (CT) with three-dimensional surface rendering to evaluate femoro-acetabular impingement. Method Thirty-six hips (30 patients; 17 males; 13 females) with persistent hip pain, mean age 41 (37–52), underwent three-dimensional CT of the pelvis, as well as MRI arthrography with gadolinium enhancement. On 3D CT, the concavity of the femoral head-neck junction (offset), alpha angle as described by Notzli was calculated to depict the anterior femoral neck contour. The concavity of the posterior aspect of the head neck junction was measured as the beta angle. The same measurements were made in 20 hips, consisting of randomly selected patients with no prior history of hip pathology or pain (mean age 37; 13 males; eight females). Results The mean alpha angle for the symptomatic group was 66.4 (39–94) and 43.8 (39.3–48.3) for the control group (p=0.001). All symptomatic hips had abnormal findings on MRA: labral tears in all; cartilage delamination/ulceration in 14 hips; herniation pits in six hips. The majority of labral tears and delamination were located in the antero-superior quadrant. In the surgical treated group, all MRA findings were confirmed. The mean beta angle was significantly smaller (increase concavity) in the symptomatic versus the controls: 40.2 versus 43.8 (p=0.011). Interestingly in the symptomatic group the beta angle was significantly lower than the alpha angle (p Conclusion: 3D CT with surface rendering and multiplanar reformation is useful to determine degree of bone buttressing of the anterior femoral head-neck junction quantitatively assessed by alpha angle measurement, which is elevated in patients with femoro-acetabular impingement. With a greater posterior concavity i.e. small beta angle in the symptomatic group versus the control, subclinical slipped femoral epiphysis remains a plausible cause of this deformity.

310 citations

Journal ArticleDOI
TL;DR: A periprosthetic cystic pseudotumor was diagnosed commonly with use of metal artifact reduction sequence (MARS) magnetic resonance imaging in this series of patients with a metal-on-metal hip prosthesis.
Abstract: Introduction: Many papers have been published recently on the subject of pseudotumors surrounding metal-on-metal hip resurfacing and replacement prostheses. These pseudotumors are sterile, inflammatory lesions within the periprosthetic tissues and have been variously termed masses, cysts, bursae, collections, or aseptic lymphocyte-dominated vasculitis-associated lesions (ALVAL). The prevalence of pseudotumors in patients with a well-functioning metal-on-metal hip prosthesis is not well known. The purpose of this study was to quantify the prevalence of pseudotumors adjacent to well-functioning and painful metal-on-metal hip prostheses, to characterize these lesions with use of magnetic resonance imaging, and to assess the relationship between their presence and acetabular cup position with use of three-dimensional computed tomography. Methods: We performed a case-control study to compare the magnetic resonance imaging findings of patients with a well-functioning unilateral metal-on-metal hip prosthesis and patients with a painful prosthesis (defined by either revision arthroplasty performed because of unexplained pain or an Oxford hip score of <30 of 48 possible points). Thirty patients with a painful hip prosthesis and twenty-eight controls with a well-functioning prosthesis were recruited consecutively. All patients also underwent computed tomography to assess the position of the acetabular component. Results: Thirty-four patients were diagnosed with a pseudotumor. However, the prevalence of pseudotumors in patients with a painful hip (seventeen of thirty, 57%) was not significantly different from the prevalence in the control group (seventeen of twenty-eight, 61%). No objective differences in pseudotumor characteristics between the groups were identified. No clear association between the presence of a pseudotumor and acetabular component position was identified. The Oxford hip score in the group with a painful hip (mean, 20.2; 95% confidence interval [CI], 12.7 to 45.8) was poorer than that in the control group (mean, 41.2; 95% CI, 18.5 to 45.8; p ≤ 0.0001). Conclusions: A periprosthetic cystic pseudotumor was diagnosed commonly (in thirty-four [59%] of the entire study cohort) with use of metal artifact reduction sequence (MARS) magnetic resonance imaging in this series of patients with a metal-on-metal hip prosthesis. The prevalence of pseudotumors was similar in patients with a well-functioning hip prosthesis and patients with a painful hip. Pseudotumors were also diagnosed commonly in patients with a well-positioned acetabular component. Although magnetic resonance imaging is useful for surgical planning, the presence of a cystic pseudotumor may not necessarily indicate the need for revision arthroplasty. Further correlation of clinical and imaging data is needed to determine the natural history of pseudotumors to guide clinical practice. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

269 citations

Patent
23 Jun 2010
TL;DR: In this article, the authors disclosed methods and devices relating improved articular models, implant components, and related guide tools and procedures that include one or more features derived from patient-data, for example, images of the patient's joint.
Abstract: Methods and devices are disclosed relating improved articular models, implant components, and related guide tools and procedures. In addition, methods and devices are disclosed relating articular models, implant components, and/or related guide tools and procedures that include one or more features derived from patient-data, for example, images of the patient's joint. The data can be used to create a model for analyzing a patient's joint and to devise and evaluate a course of corrective action. The data also can be used to create patient-adapted implant components and related tools and procedures.

260 citations

Journal ArticleDOI
TL;DR: The authors prefer the use of generic instruments to perform kinematically aligned TKA in place of mechanicallyaligned TKA because five of six alignments were accurate and because high function was restored regardless of whether patients had an alignment categorized as an outlier or in-range.
Abstract: Purpose Performing kinematically aligned total knee arthroplasty (TKA) with generic instruments is less costly than patient-specific instrumentation; however, the alignment and function with this new technique are unknown.

254 citations