Author
G. Eurin
Bio: G. Eurin is an academic researcher from Max Planck Society. The author has contributed to research in topics: Dark matter & Time projection chamber. The author has an hindex of 27, co-authored 45 publications receiving 4967 citations.
Papers
More filters
••
Columbia University1, University of Amsterdam2, University of Bologna3, University of Mainz4, University of Münster5, University of Coimbra6, New York University Abu Dhabi7, University of Zurich8, Stockholm University9, Rensselaer Polytechnic Institute10, Max Planck Society11, Weizmann Institute of Science12, University of Freiburg13, University of Nantes14, University of California, San Diego15, University of Chicago16, Purdue University17, Rice University18, Pierre-and-Marie-Curie University19, University of California, Los Angeles20
TL;DR: In this article, a search for weakly interacting massive particles (WIMPs) using 278.8 days of data collected with the XENON1T experiment at LNGS is reported.
Abstract: We report on a search for weakly interacting massive particles (WIMPs) using 278.8 days of data collected with the XENON1T experiment at LNGS. XENON1T utilizes a liquid xenon time projection chamber with a fiducial mass of (1.30±0.01) ton, resulting in a 1.0 ton yr exposure. The energy region of interest, [1.4,10.6] keVee ([4.9,40.9] keVnr), exhibits an ultralow electron recoil background rate of [82-3+5(syst)±3(stat)] events/(ton yr keVee). No significant excess over background is found, and a profile likelihood analysis parametrized in spatial and energy dimensions excludes new parameter space for the WIMP-nucleon spin-independent elastic scatter cross section for WIMP masses above 6 GeV/c2, with a minimum of 4.1×10-47 cm2 at 30 GeV/c2 and a 90% confidence level.
1,808 citations
••
Columbia University1, University of Amsterdam2, University of Mainz3, University of Coimbra4, New York University Abu Dhabi5, University of Zurich6, Stockholm University7, Rensselaer Polytechnic Institute8, Max Planck Society9, Weizmann Institute of Science10, University of Freiburg11, Purdue University12, University of Nantes13, University of Bologna14, University of California, San Diego15, University of Münster16, University of Chicago17, Rice University18, Pierre-and-Marie-Curie University19, University of California, Los Angeles20
TL;DR: The first dark matter search results from XENON1T, a ∼2000-kg-target-mass dual-phase (liquid-gas) xenon time projection chamber in operation at the Laboratori Nazionali del Gran Sasso in Italy, are reported and a profile likelihood analysis shows that the data are consistent with the background-only hypothesis.
Abstract: We report the first dark matter search results from XENON1T, a ∼2000-kg-target-mass dual-phase (liquid-gas) xenon time projection chamber in operation at the Laboratori Nazionali del Gran Sasso in Italy and the first ton-scale detector of this kind The blinded search used 342 live days of data acquired between November 2016 and January 2017 Inside the (1042±12)-kg fiducial mass and in the [5,40] keVnr energy range of interest for weakly interacting massive particle (WIMP) dark matter searches, the electronic recoil background was (193±025)×10-4 events/(kg×day×keVee), the lowest ever achieved in such a dark matter detector A profile likelihood analysis shows that the data are consistent with the background-only hypothesis We derive the most stringent exclusion limits on the spin-independent WIMP-nucleon interaction cross section for WIMP masses above 10 GeV/c2, with a minimum of 77×10-47 cm2 for 35-GeV/c2 WIMPs at 90% CL
1,061 citations
••
University of Amsterdam1, University of Bologna2, University of Mainz3, University of Coimbra4, University of Bern5, Columbia University6, Weizmann Institute of Science7, New York University Abu Dhabi8, University of Zurich9, Rensselaer Polytechnic Institute10, Max Planck Society11, Stockholm University12, University of Nantes13, Karlsruhe Institute of Technology14, University of Münster15, University of Chicago16, Arizona State University17, Purdue University18, Rice University19, University of California, San Diego20, University of Freiburg21, Dresden University of Technology22, Imperial College London23, University of California, Los Angeles24
TL;DR: DARk matter WImp search with liquid xenoN (DARWIN) as mentioned in this paper is an experiment for the direct detection of dark matter using a multi-ton liquid xenon time projection chamber at its core.
Abstract: DARk matter WImp search with liquid xenoN (DARWIN(2)) will be an experiment for the direct detection of dark matter using a multi-ton liquid xenon time projection chamber at its core. Its primary g ...
553 citations
••
Columbia University1, University of Bologna2, Istituto Nazionale di Fisica Nucleare3, University of Mainz4, University of Münster5, University of Coimbra6, University of Turin7, University of Amsterdam8, New York University Abu Dhabi9, University of Zurich10, Rensselaer Polytechnic Institute11, Weizmann Institute of Science12, Max Planck Society13, Purdue University14, University of Freiburg15, University of L'Aquila16, University of Tokyo17, Nagoya University18, Konan University19, University of California, San Diego20, University of Chicago21, Rice University22, University of California, Los Angeles23
TL;DR: In this article, the XENON1T data was used for searches for new physics with low-energy electronic recoil data recorded with the Xenon1T detector, which enabled one of the most sensitive searches for solar axions, an enhanced neutrino magnetic moment using solar neutrinos, and bosonic dark matter.
Abstract: We report results from searches for new physics with low-energy electronic recoil data recorded with the XENON1T detector. With an exposure of 0.65 tonne-years and an unprecedentedly low background rate of 76±2stat events/(tonne×year×keV) between 1 and 30 keV, the data enable one of the most sensitive searches for solar axions, an enhanced neutrino magnetic moment using solar neutrinos, and bosonic dark matter. An excess over known backgrounds is observed at low energies and most prominent between 2 and 3 keV.
The solar axion model has a 3.4σ significance, and a three-dimensional 90% confidence surface is reported for axion couplings to electrons, photons, and nucleons. This surface is inscribed in the cuboid defined by gae<3.8×10-12, gaeganeff<4.8×10-18, and gaegaγ<7.7×10-22 GeV-1, and excludes either gae=0 or gaegaγ=gaeganeff=0. The neutrino magnetic moment signal is similarly favored over background at 3.2σ, and a confidence interval of μν∈(1.4,2.9)×10-11 μB (90% C.L.) is reported. Both results are in strong tension with stellar constraints. The excess can also be explained by β decays of tritium at 3.2σ significance with a corresponding tritium concentration in xenon of (6.2±2.0)×10-25 mol/mol. Such a trace amount can neither be confirmed nor excluded with current knowledge of its production and reduction mechanisms. The significances of the solar axion and neutrino magnetic moment hypotheses are decreased to 2.0σ and 0.9σ, respectively, if an unconstrained tritium component is included in the fitting. With respect to bosonic dark matter, the excess favors a monoenergetic peak at (2.3±0.2) keV (68% C.L.) with a 3.0σ global (4.0σ local) significance over background.
This analysis sets the most restrictive direct constraints to date on pseudoscalar and vector bosonic dark matter for most masses between 1 and 210 keV/c2. We also consider the possibility that Ar37 may be present in the detector, yielding a 2.82 keV peak from electron capture. Contrary to tritium, the Ar37 concentration can be tightly constrained and is found to be negligible.
452 citations
••
Columbia University1, Stockholm University2, University of Bologna3, University of Mainz4, University of Münster5, University of Coimbra6, University of Turin7, New York University Abu Dhabi8, University of Zurich9, Rensselaer Polytechnic Institute10, University of Amsterdam11, Max Planck Society12, Weizmann Institute of Science13, University of Freiburg14, University of Nantes15, Purdue University16, University of California, San Diego17, University of Chicago18, Nagoya University19, Pierre-and-Marie-Curie University20, Université Paris-Saclay21, Rice University22, University of California, Los Angeles23
TL;DR: Constraints on light dark matter (DM) models using ionization signals in the XENON1T experiment are reported, and no DM or CEvNS detection may be claimed because the authors cannot model all of their backgrounds.
Abstract: We report constraints on light dark matter (DM) models using ionization signals in the XENON1T experiment. We mitigate backgrounds with strong event selections, rather than requiring a scintillation signal, leaving an effective exposure of (22±3) tonne day. Above ∼0.4 keVee, we observe 30 MeV/c2, and absorption of dark photons and axionlike particles for mχ within 0.186–1 keV/c2.
412 citations
Cited by
More filters
••
Columbia University1, University of Amsterdam2, University of Bologna3, University of Mainz4, University of Münster5, University of Coimbra6, New York University Abu Dhabi7, University of Zurich8, Stockholm University9, Rensselaer Polytechnic Institute10, Max Planck Society11, Weizmann Institute of Science12, University of Freiburg13, University of Nantes14, University of California, San Diego15, University of Chicago16, Purdue University17, Rice University18, Pierre-and-Marie-Curie University19, University of California, Los Angeles20
TL;DR: In this article, a search for weakly interacting massive particles (WIMPs) using 278.8 days of data collected with the XENON1T experiment at LNGS is reported.
Abstract: We report on a search for weakly interacting massive particles (WIMPs) using 278.8 days of data collected with the XENON1T experiment at LNGS. XENON1T utilizes a liquid xenon time projection chamber with a fiducial mass of (1.30±0.01) ton, resulting in a 1.0 ton yr exposure. The energy region of interest, [1.4,10.6] keVee ([4.9,40.9] keVnr), exhibits an ultralow electron recoil background rate of [82-3+5(syst)±3(stat)] events/(ton yr keVee). No significant excess over background is found, and a profile likelihood analysis parametrized in spatial and energy dimensions excludes new parameter space for the WIMP-nucleon spin-independent elastic scatter cross section for WIMP masses above 6 GeV/c2, with a minimum of 4.1×10-47 cm2 at 30 GeV/c2 and a 90% confidence level.
1,808 citations
••
Columbia University1, University of Amsterdam2, University of Mainz3, University of Coimbra4, New York University Abu Dhabi5, University of Zurich6, Stockholm University7, Rensselaer Polytechnic Institute8, Max Planck Society9, Weizmann Institute of Science10, University of Freiburg11, Purdue University12, University of Nantes13, University of Bologna14, University of California, San Diego15, University of Münster16, University of Chicago17, Rice University18, Pierre-and-Marie-Curie University19, University of California, Los Angeles20
TL;DR: The first dark matter search results from XENON1T, a ∼2000-kg-target-mass dual-phase (liquid-gas) xenon time projection chamber in operation at the Laboratori Nazionali del Gran Sasso in Italy, are reported and a profile likelihood analysis shows that the data are consistent with the background-only hypothesis.
Abstract: We report the first dark matter search results from XENON1T, a ∼2000-kg-target-mass dual-phase (liquid-gas) xenon time projection chamber in operation at the Laboratori Nazionali del Gran Sasso in Italy and the first ton-scale detector of this kind The blinded search used 342 live days of data acquired between November 2016 and January 2017 Inside the (1042±12)-kg fiducial mass and in the [5,40] keVnr energy range of interest for weakly interacting massive particle (WIMP) dark matter searches, the electronic recoil background was (193±025)×10-4 events/(kg×day×keVee), the lowest ever achieved in such a dark matter detector A profile likelihood analysis shows that the data are consistent with the background-only hypothesis We derive the most stringent exclusion limits on the spin-independent WIMP-nucleon interaction cross section for WIMP masses above 10 GeV/c2, with a minimum of 77×10-47 cm2 for 35-GeV/c2 WIMPs at 90% CL
1,061 citations
••
Columbia University1, University of Amsterdam2, University of Bologna3, University of Mainz4, University of Coimbra5, Weizmann Institute of Science6, New York University Abu Dhabi7, University of Zurich8, Stockholm University9, Rensselaer Polytechnic Institute10, Max Planck Society11, University of Münster12, University of Bern13, Purdue University14, École des mines de Nantes15, University of California, Los Angeles16, Rice University17
TL;DR: In this article, the expected sensitivity of the Xenon1T experiment to the spin-independent WIMP-nucleon interaction cross section was investigated based on Monte Carlo predictions of the electronic and nuclear recoil backgrounds.
Abstract: The XENON1T experiment is currently in the commissioning phase at the Laboratori Nazionali del Gran Sasso, Italy. In this article we study the experiment's expected sensitivity to the spin-independent WIMP-nucleon interaction cross section, based on Monte Carlo predictions of the electronic and nuclear recoil backgrounds. The total electronic recoil background in 1 tonne fiducial volume and (1, 12) keV electronic recoil equivalent energy region, before applying any selection to discriminate between electronic and nuclear recoils, is (1.80 ± 0.15) · 10(−)(4) (kg·day·keV)(−)(1), mainly due to the decay of (222)Rn daughters inside the xenon target. The nuclear recoil background in the corresponding nuclear recoil equivalent energy region (4, 50) keV, is composed of (0.6 ± 0.1) (t·y)(−)(1) from radiogenic neutrons, (1.8 ± 0.3) · 10(−)(2) (t·y)(−)(1) from coherent scattering of neutrinos, and less than 0.01 (t·y)(−)(1) from muon-induced neutrons. The sensitivity of XENON1T is calculated with the Profile Likelihood Ratio method, after converting the deposited energy of electronic and nuclear recoils into the scintillation and ionization signals seen in the detector. We take into account the systematic uncertainties on the photon and electron emission model, and on the estimation of the backgrounds, treated as nuisance parameters. The main contribution comes from the relative scintillation efficiency Script L(eff), which affects both the signal from WIMPs and the nuclear recoil backgrounds. After a 2 y measurement in 1 t fiducial volume, the sensitivity reaches a minimum cross section of 1.6 · 10(−)(47) cm(2) at m(χ) = 50 GeV/c(2).
580 citations
••
TL;DR: The analysis indicates that the spatial fluctuations of the 21-centimetre signal at cosmic dawn could be an order of magnitude larger than previously expected and that the dark-matter particle is no heavier than several proton masses, well below the commonly predicted mass of weakly interacting massive particles.
Abstract: The large absorption of the 21-centimetre transition of hydrogen around redshift 20 is explained by radiation from the first stars, combined with excess cooling of the cosmic gas caused by baryon–dark matter scattering. As the first stars heated hydrogen in the early Universe, the 21-cm hyperfine line—an astronomical standard that represents the spin-flip transition in the ground state of atomic hydrogen—was altered, causing the hydrogen gas to absorb photons from the microwave background. This should produce an observable absorption signal at frequencies of less than 200 megahertz (MHz). Judd Bowman and colleagues report the observation of an absorption profile centred at a frequency of 78 MHz that is about 19 MHz wide and 0.5 kelvin deep. The profile is generally in line with expectations, although it is deeper than predicted. An accompanying paper by Rennan Barkana suggests that baryons were interacting with cold dark-matter particles in the early Universe, cooling the gas more than had been expected. The cosmic radio-frequency spectrum is expected to show a strong absorption signal corresponding to the 21-centimetre-wavelength transition of atomic hydrogen around redshift 20, which arises from Lyman-α radiation from some of the earliest stars1,2,3,4. By observing this 21-centimetre signal—either its sky-averaged spectrum5 or maps of its fluctuations, obtained using radio interferometers6,7—we can obtain information about cosmic dawn, the era when the first astrophysical sources of light were formed. The recent detection of the global 21-centimetre spectrum5 reveals a stronger absorption than the maximum predicted by existing models, at a confidence level of 3.8 standard deviations. Here we report that this absorption can be explained by the combination of radiation from the first stars and excess cooling of the cosmic gas induced by its interaction with dark matter8,9,10. Our analysis indicates that the spatial fluctuations of the 21-centimetre signal at cosmic dawn could be an order of magnitude larger than previously expected and that the dark-matter particle is no heavier than several proton masses, well below the commonly predicted mass of weakly interacting massive particles. Our analysis also confirms that dark matter is highly non-relativistic and at least moderately cold, and primordial velocities predicted by models of warm dark matter are potentially detectable. These results indicate that 21-centimetre cosmology can be used as a dark-matter probe.
487 citations