scispace - formally typeset
Search or ask a question
Author

Giorgio Di Rocco

Bio: Giorgio Di Rocco is an academic researcher from Sapienza University of Rome. The author has contributed to research in topics: Thyroid nodules & Thyroidectomy. The author has an hindex of 12, co-authored 23 publications receiving 545 citations.

Papers
More filters
Journal ArticleDOI
TL;DR: The aim of the present paper is to provide an update of the literature on different available techniques and the results reported both for thyroid nodules differentiation and for diffuse thyroid disease evaluation.

107 citations

Journal ArticleDOI
TL;DR: A systematic review to evaluate the role of Ultrasonic dissector (UAS) versus conventional clamp and tie in thyroidectomy shown a relevant advantage only in terms of cost-effectiveness in patients treated with UAS; it is subsequent to statistically significant reduction of operation duration, intraoperative blood loss and of overall drainage volume during the first 24 hours.
Abstract: We conducted a systematic review to evaluate the role of Ultrasonic dissector (UAS) versus conventional clamp and tie in thyroidectomy. We searched for all published RCT in into electronic databases. To be included in the analysis, the studies had to compare thyroidectomy with UAS versus conventional vessel ligation and tight (conventional technique = CT). The following outcomes were used to compare the total thyroidectomy group with UAS versus CT group: operative duration, operative blood loss, overall drainage volume during the first 24 hours, transiet laryngeal nerve palsy, permanent laryngeal nerve palsy, transiet hypocalcaemia and permanent hypocalcaemia. There are currently 7 RCT on this issue to compare thyroidectomy with UAS versus CT. From the analysis of these studies it was possible to confront 608 cases: 303 undergoing to thyroidectomy with UAS versus 305 that were treated with CT. Actually, it was shown a relevant advantage of cost-effectiveness in patients treated with UAS; there is a statistically significant reduction of the operative duration (weighted mean difference [WMD], -18.74 minutes; 95% confidence interval [CI], (-26.97 to -10.52 minutes) (P = 0.00001), intraoperative blood loss (WMD, -60.10 mL; 95% CI, -117.04 to 3.16 mL) (P = 0.04) and overall drainage volume (WMD, -35.30 mL; 95% CI, -49.24 to 21.36 mL) (P = 0.00001) in the patients underwent thyroidectomy with UAS. Although the analysis showed that the patients who were treated with USA presented more favourable results in incidence of post-operative complications (transient laryngeal nerve palsy: P = 0.11; permanent laryngeal nerve palsy: not estimable; transient hypocalcaemia: P = 0.24; permanent hypocalcaemia: P = 0.45), these data didn't present statistical relevance. This meta-analysis shown a relevant advantage only in terms of cost-effectiveness in patients treated with UAS; it is subsequent to statistically significant reduction of operation duration, intraoperative blood loss and of overall drainage volume during the first 24 hours. Although the analysis showed that the patients who were treated with UAS presented more favourable results in incidence of post-operative complications (transiet laryngeal nerve palsy; transiet hypocalcaemia and permanent hypocalcaemia), these data didn't present statistical relevance.

67 citations

Journal ArticleDOI
TL;DR: Q-elastography showed excellent diagnostic performance for the prediction of thyroid malignancy and is a valid and reproducible diagnostic method as well as a promising tool for identifying suspicious solid thyroid nodules needing cytological assessment and surgery.
Abstract: Objective Evaluation of the diagnostic efficacy and interobserver agreement of Q-elastography in the differentiation of benign from malignant thyroid nodules.

64 citations

Journal ArticleDOI
27 Feb 2013-PLOS ONE
TL;DR: The Nintendo® Wii™ might be helpful, inexpensive and entertaining part of the training of young laparoscopists, in addition to a standard surgical education based on simulators and the operating room.
Abstract: Background Video-games have become an integral part of the new multimedia culture. Several studies assessed video-gaming enhancement of spatial attention and eye-hand coordination. Considering the technical difficulty of laparoscopic procedures, legal issues and time limitations, the validation of appropriate training even outside of the operating rooms is ongoing. We investigated the influence of a four-week structured Nintendo® Wii™ training on laparoscopic skills by analyzing performance metrics with a validated simulator (Lap Mentor™, Simbionix™). Methodology/Principal Findings We performed a prospective randomized study on 42 post-graduate I–II year residents in General, Vascular and Endoscopic Surgery. All participants were tested on a validated laparoscopic simulator and then randomized to group 1 (Controls, no training with the Nintendo® Wii™), and group 2 (training with the Nintendo® Wii™) with 21 subjects in each group, according to a computer-generated list. After four weeks, all residents underwent a testing session on the laparoscopic simulator of the same tasks as in the first session. All 42 subjects in both groups improved significantly from session 1 to session 2. Compared to controls, the Wii group showed a significant improvement in performance (p<0.05) for 13 of the 16 considered performance metrics. Conclusions/Significance The Nintendo® Wii™ might be helpful, inexpensive and entertaining part of the training of young laparoscopists, in addition to a standard surgical education based on simulators and the operating room.

60 citations

Journal ArticleDOI
TL;DR: USE with strain ratio should be considered a useful additional tool to colour-Doppler US, since it improves characterisation of thyroid nodules with indeterminate cytology, and may help to better select patients with Thy 3 nodules candidate for surgery.
Abstract: To assess whether ultrasound elastography (USE) with strain ratio increases diagnostic accuracy of Doppler ultrasound in further characterisation of cytologically Thy3 thyroid nodules. In two different university diagnostic centres, 315 patients with indeterminate cytology (Thy3) in thyroid nodules aspirates were prospectively evaluated with Doppler ultrasound and strain ratio USE before surgery. Ultrasonographic features were analysed separately and together as ultrasound score, to assess sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). Receiver operating characteristic (ROC) curves to identify optimal cut-off value of the strain ratio were also provided. Diagnosis on a surgical specimen was considered the standard of reference. Higher strain ratio values were found in malignant nodules, with an optimum strain ratio cut-off of 2.09 at ROC analysis. USE with strain ratio showed 90.6 % sensitivity, 93 % specificity, 82.8 % PPV, 96.4 % NPV, while US score yielded a sensitivity of 52.9 %, specificity of 84.3 %, PPV 55.6 % and NPV 82.9 %. The diagnostic gain with strain ratio was statistically significant as proved by ROC areas, which was 0.9182 for strain ratio and 0.6864 for US score. USE with strain ratio should be considered a useful additional tool to colour-Doppler US, since it improves characterisation of thyroid nodules with indeterminate cytology. • Strain ratio measurements improve differentiation of thyroid nodules with indeterminate cytology • Elastography with strain ratio is more reliable than ultrasound features and ultrasound score • Strain ratio may help to better select patients with Thy 3 nodules candidate for surgery

53 citations


Cited by
More filters
Journal ArticleDOI
01 Oct 2016-Thyroid
TL;DR: One hundred twenty-four evidence-based recommendations were developed to aid in the care of patients with thyrotoxicosis and to share what the task force believes is current, rational, and optimal medical practice.
Abstract: Background Thyrotoxicosis has multiple etiologies, manifestations, and potential therapies. Appropriate treatment requires an accurate diagnosis and is influenced by coexisting medical conditions and patient preference. This document describes evidence-based clinical guidelines for the management of thyrotoxicosis that would be useful to generalist and subspecialty physicians and others providing care for patients with this condition. Methods The American Thyroid Association (ATA) previously cosponsored guidelines for the management of thyrotoxicosis that were published in 2011. Considerable new literature has been published since then, and the ATA felt updated evidence-based guidelines were needed. The association assembled a task force of expert clinicians who authored this report. They examined relevant literature using a systematic PubMed search supplemented with additional published materials. An evidence-based medicine approach that incorporated the knowledge and experience of the panel was used to update the 2011 text and recommendations. The strength of the recommendations and the quality of evidence supporting them were rated according to the approach recommended by the Grading of Recommendations, Assessment, Development, and Evaluation Group. Results Clinical topics addressed include the initial evaluation and management of thyrotoxicosis; management of Graves' hyperthyroidism using radioactive iodine, antithyroid drugs, or surgery; management of toxic multinodular goiter or toxic adenoma using radioactive iodine or surgery; Graves' disease in children, adolescents, or pregnant patients; subclinical hyperthyroidism; hyperthyroidism in patients with Graves' orbitopathy; and management of other miscellaneous causes of thyrotoxicosis. New paradigms since publication of the 2011 guidelines are presented for the evaluation of the etiology of thyrotoxicosis, the management of Graves' hyperthyroidism with antithyroid drugs, the management of pregnant hyperthyroid patients, and the preparation of patients for thyroid surgery. The sections on less common causes of thyrotoxicosis have been expanded. Conclusions One hundred twenty-four evidence-based recommendations were developed to aid in the care of patients with thyrotoxicosis and to share what the task force believes is current, rational, and optimal medical practice.

1,446 citations

Journal ArticleDOI
TL;DR: While ultrasound elastography has shown promising results for non-invasive assessment of liver fibrosis, new applications in breast, thyroid, prostate, kidney and lymph node imaging are emerging.
Abstract: Elastography-based imaging techniques have received substantial attention in recent years for non-invasive assessment of tissue mechanical properties. These techniques take advantage of changed soft tissue elasticity in various pathologies to yield qualitative and quantitative information that can be used for diagnostic purposes. Measurements are acquired in specialized imaging modes that can detect tissue stiffness in response to an applied mechanical force (compression or shear wave). Ultrasound-based methods are of particular interest due to its many inherent advantages, such as wide availability including at the bedside and relatively low cost. Several ultrasound elastography techniques using different excitation methods have been developed. In general, these can be classified into strain imaging methods that use internal or external compression stimuli, and shear wave imaging that use ultrasound-generated traveling shear wave stimuli. While ultrasound elastography has shown promising results for non-invasive assessment of liver fibrosis, new applications in breast, thyroid, prostate, kidney and lymph node imaging are emerging. Here, we review the basic principles, foundation physics, and limitations of ultrasound elastography and summarize its current clinical use and ongoing developments in various clinical applications.

995 citations

Journal ArticleDOI
TL;DR: The molecular functions of protein lysine methylation and its involvement in human cancer are summarized, with a particular focus on lysines methylation of non-histone proteins.
Abstract: Several protein lysine methyltransferases and demethylases have been identified to have critical roles in histone modification. A large body of evidence has indicated that their dysregulation is involved in the development and progression of various diseases, including cancer, and these enzymes are now considered to be potential therapeutic targets. Although most studies have focused on histone methylation, many reports have revealed that these enzymes also regulate the methylation dynamics of non-histone proteins such as p53, RB1 and STAT3 (signal transducer and activator of transcription 3), which have important roles in human tumorigenesis. In this Review, we summarize the molecular functions of protein lysine methylation and its involvement in human cancer, with a particular focus on lysine methylation of non-histone proteins.

292 citations

Journal ArticleDOI
TL;DR: US-SE, ADC, and signal intensity on T2-weighted sequences on MR prove to be useful tools for the evaluation of CD pattern.
Abstract: Purpose. To evaluate and compare the mesenteric and bowel wall changes during Crohn’s disease (CD) on ultrasonography (US) Strain Elastography (SE) and Enterography Magnetic Resonance Imaging (E-MRI). Methods. From July 2014 to September 2016, 35 patients with ileocolonoscopy diagnosis of CD were prospectively examined with E-MRI and in the same time with US and SE. Results. A total of 41 affected bowel segments and 35 unaffected bowel segments in 35 patients were evaluated. US-SE color-scale coding showed a blue color pattern in the fibrotic mesentery and bowel wall in 15 patients and a green color pattern in the edematous ones in 20 patients. The signal of the bowel wall and mesenteric fat was iso/hypointense on T2-weighted sequence in the fibrotic pattern (23/35 and 12/35 patients) and hyperintense in the edematous pattern (12/35 and 23/35 patients). Mean ADC values were, respectively, 2, ,33 × 10−3 for the fibrotic mesentery and 2, ,28 × 10−3 for edematous one. There was a statistical correlation between US-SE color-scale and T2 signal intensity and between the US-SE color-scale and ADC maps. Conclusions. US-SE, ADC, and signal intensity on T2-weighted sequences on MR prove to be useful tools for the evaluation of CD pattern.

291 citations

Journal ArticleDOI
TL;DR: Serious gaming/gamification appears to be at least as effective as controls, and in many studies, more effective for improving knowledge, skills, and satisfaction, however, the available evidence is mostly of low quality and calls for further rigorous, theory-driven research.
Abstract: Background: There is a worldwide shortage of health workers, and this issue requires innovative education solutions. Serious gaming and gamification education have the potential to provide a quality, cost-effective, novel approach that is flexible, portable, and enjoyable and allow interaction with tutors and peers. Objective: The aim of this systematic review was to evaluate the effectiveness of serious gaming/gamification for health professions education compared with traditional learning, other types of digital education, or other serious gaming/gamification interventions in terms of patient outcomes, knowledge, skills, professional attitudes, and satisfaction (primary outcomes) as well as economic outcomes of education and adverse events (secondary outcomes). Methods: A comprehensive search of MEDLINE, EMBASE, Web of Knowledge, Educational Resources Information Centre, Cochrane Central Register of Controlled Trials, PsycINFO, and Cumulative Index to Nursing and Allied Health Literature was conducted from 1990 to August 2017. Randomized controlled trials (RCTs) and cluster RCTs were eligible for inclusion. Two reviewers independently searched, screened, and assessed the study quality and extracted data. A meta-analysis was not deemed appropriate due to the heterogeneity of populations, interventions, comparisons, and outcomes. Therefore, a narrative synthesis is presented. Results: A total of 27 RCTs and 3 cluster RCTs with 3634 participants were included. Two studies evaluated gamification interventions, and the remaining evaluated serious gaming interventions. One study reported a small statistically significant difference between serious gaming and digital education of primary care physicians in the time to control blood pressure in a subgroup of their patients already taking antihypertensive medications. There was evidence of a moderate-to-large magnitude of effect from five studies evaluating individually delivered interventions for objectively measured knowledge compared with traditional learning. There was also evidence of a small-to-large magnitude of effect from 10 studies for improved skills compared with traditional learning. Two and four studies suggested equivalence between interventions and controls for knowledge and skills, respectively. Evidence suggested that serious gaming was at least as effective as other digital education modalities for these outcomes. There was insufficient evidence to conclude whether one type of serious gaming/gamification intervention is more effective than any other. There was limited evidence for the effects of serious gaming/gamification on professional attitudes. Serious gaming/gamification may improve satisfaction, but the evidence was limited. Evidence was of low or very low quality for all outcomes. Quality of evidence was downgraded due to the imprecision, inconsistency, and limitations of the study. Conclusions: Serious gaming/gamification appears to be at least as effective as controls, and in many studies, more effective for improving knowledge, skills, and satisfaction. However, the available evidence is mostly of low quality and calls for further rigorous, theory-driven research.

256 citations