Author
Giovanni Pierattini
Other affiliations: Olivetti
Bio: Giovanni Pierattini is an academic researcher from ARCO. The author has contributed to research in topic(s): Digital holography & Holography. The author has an hindex of 25, co-authored 128 publication(s) receiving 3222 citation(s). Previous affiliations of Giovanni Pierattini include Olivetti.
Papers published on a yearly basis
Papers
More filters
TL;DR: An approach is proposed for removing the wavefront curvature introduced by the microscope imaging objective in digital holography, which otherwise hinders the phase contrast imaging at reconstruction planes and it is shown that a correction effect can be obtained at all reconstruction planes.
Abstract: An approach is proposed for removing the wave front curvature introduced by the microscope imaging objective in digital holography, which otherwise hinders the phase contrast imaging at reconstruction planes. The unwanted curvature is compensated by evaluating a correcting wave front at the hologram plane with no need for knowledge of the optical parameters, focal length of the imaging lens, or distances in the setup. Most importantly it is shown that a correction effect can be obtained at all reconstruction planes. Three different methods have been applied to evaluate the correction wave front and the methods are discussed in detail. The proposed approach is demonstrated by applying digital holography as a method of coherent microscopy for imaging amplitude and phase contrast of microstructures.
376 citations
TL;DR: It is shown that this technique can be efficiently used for obtaining quantitative information from the intensity and the phase distributions of the reconstructed field at different locations along the propagation direction.
Abstract: In this paper, we have investigated on the potentialities of digital holography for whole reconstruction of wavefields. We show that this technique can be efficiently used for obtaining quantitative information from the intensity and the phase distributions of the reconstructed field at different locations along the propagation direction. The basic concept and procedure of wavefield reconstruction for digital in-line holography is discussed. Numerical reconstructions of the wavefield from digitally recorded in-line hologram patterns and from simulated test patterns are presented. The potential of the method for analysing aberrated wave front has been exploited by applying the reconstruction procedure to astigmatic hologram patterns.
268 citations
TL;DR: It is demonstrated that an extended focused image of an object can be obtained through digital holography without any mechanical scanning or special optical components.
Abstract: In microscopy, high magnifications are achievable for investigating micro-objects but the paradigm is that higher is the required magnification, lower is the depth of focus. For an object having a three-dimensional (3D) complex shape only a portion of it appears in good focus to the observer who is essentially looking at a single image plane. Actually, two approaches exist to obtain an extended focused image, both having severe limitations since the first requires mechanical scanning while the other one requires specially designed optics. We demonstrate that an extended focused image of an object can be obtained through digital holography without any mechanical scanning or special optical components. The conceptual novelty of the proposed approach lies in the fact that it is possible to completely exploit the unique feature of DH in extracting all the information content stored in hologram, amplitude and phase, to extend the depth of focus.
263 citations
TL;DR: A method for controlling the size of amplitude and phase images reconstructed from digital holograms by the Fresnel-transform method is proposed and demonstrated and solves the problem of superimposition in multiwavelength digital holography for color display and holographic interferometry applications.
Abstract: A method for controlling the size of amplitude and phase images reconstructed from digital holograms by the Fresnel-transform method is proposed and demonstrated. The method can provide a constant reconstruction pixel width in the reconstructed image plane, independent of the recording and reconstruction distance. The proposed method makes it possible to maintain the size of an object for a sequence of digital holograms recorded at different distances and, therefore, to subtract phase maps for an object recorded at different distances. Furthermore, the method solves the problem of superimposition in multiwavelength digital holography for color display and holographic interferometry applications.
237 citations
TL;DR: A new method for focus tracking during the recording of a sequence of digital holograms while the sample experiences axial displacement is proposed and can be applied as a quasi-real-time procedure.
Abstract: We propose a new method for focus tracking during the recording of a sequence of digital holograms while the sample experiences axial displacement. Corrected reconstruction distances can be automatically calculated, and well-focused amplitude and phase-contrast images can be obtained for each digitized hologram. The method is demonstrated for inspection of microelectromechanical systems subjected to thermal load. The method can be applied as a quasi-real-time procedure.
162 citations
Cited by
More filters
Journal Article•
TL;DR: In this article, a fast Fourier transform method of topography and interferometry is proposed to discriminate between elevation and depression of the object or wave-front form, which has not been possible by the fringe-contour generation techniques.
Abstract: A fast-Fourier-transform method of topography and interferometry is proposed. By computer processing of a noncontour type of fringe pattern, automatic discrimination is achieved between elevation and depression of the object or wave-front form, which has not been possible by the fringe-contour-generation techniques. The method has advantages over moire topography and conventional fringe-contour interferometry in both accuracy and sensitivity. Unlike fringe-scanning techniques, the method is easy to apply because it uses no moving components.
3,742 citations
TL;DR: In this article, the physical mechanisms and the main experimental parameters involved in femtosecond laser micromachining of transparent materials, and important emerging applications of the technology are described.
Abstract: Femtosecond laser micromachining can be used either to remove materials or to change a material's properties, and can be applied to both absorptive and transparent substances. Over the past decade, this technique has been used in a broad range of applications, from waveguide fabrication to cell ablation. This review describes the physical mechanisms and the main experimental parameters involved in the femtosecond laser micromachining of transparent materials, and important emerging applications of the technology. Interactions between laser and matter are fascinating and have found a wide range of applications. This article gives an overview of the fundamental physical mechanisms in the processing of transparent materials using ultrafast lasers, as well as important emerging applications of the technology.
2,263 citations
TL;DR: The principles and major applications of digital recording and numerical reconstruction of holograms (digital holography) are described, which are applied to measure shape and surface deformation of opaque bodies and refractive index fields within transparent media.
Abstract: This article describes the principles and major applications of digital recording and numerical reconstruction of holograms (digital holography). Digital holography became feasible since charged coupled devices (CCDs) with suitable numbers and sizes of pixels and computers with sufficient speed became available. The Fresnel or Fourier holograms are recorded directly by the CCD and stored digitally. No film material involving wet-chemical or other processing is necessary. The reconstruction of the wavefield, which is done optically by illumination of a hologram, is performed by numerical methods. The numerical reconstruction process is based on the Fresnel–Kirchhoff integral, which describes the diffraction of the reconstructing wave at the micro-structure of the hologram. In the numerical reconstruction process not only the intensity, but also the phase distribution of the stored wavefield can be computed from the digital hologram. This offers new possibilities for a variety of applications. Digital holography is applied to measure shape and surface deformation of opaque bodies and refractive index fields within transparent media. Further applications are imaging and microscopy, where it is advantageous to refocus the area under investigation by numerical methods.
1,104 citations
TL;DR: This paper presents a meta-analyses of Fourier-Transform Profilometry and its applications in 3-D Shape Measurement and Surface Profile Measurement for Structured Light Pattern and 4-Core Optical-Fiber.
Abstract: Keywords: Fourier-Transform Profilometry ; 3-Dimensional Shape Measurement ; Phase-Unwrapping Algorithm ; Continuous Wavelet Transform ; Surface Profile Measurement ; 3-D Object Shapes ; Structured Light Pattern ; 4-Core Optical-Fiber ; Deformation Measurements ; Shifting Profilometry Reference IMAC-REVIEW-2009-001doi:10.1016/j.optlaseng.2009.09.001View record in Web of Science Record created on 2009-09-02, modified on 2016-08-08
954 citations
TL;DR: Techniques of digital holography are improved in order to obtain high-resolution, high-fidelity images of quantitative phase-contrast microscopy, and the angular spectrum method of calculating holographic optical field is seen to have significant advantages including tight control of spurious noise components.
Abstract: Techniques of digital holography are improved in order to obtain high-resolution, high-fidelity images of quantitative phase-contrast microscopy. In particular, the angular spectrum method of calculating holographic optical field is seen to have significant advantages including tight control of spurious noise components. Holographic phase images are obtained with 0.5 μm diffraction-limited lateral resolution and largely immune from the coherent noise common in other holographic techniques. The phase profile is accurate to about 30 nm of optical thickness. Images of SKOV-3 ovarian cancer cells display intracellular and intranuclear organelles with clarity and quantitative accuracy.
605 citations