scispace - formally typeset
Search or ask a question
Author

Giselle Rangel

Bio: Giselle Rangel is an academic researcher. The author has contributed to research in topics: Serology & Seroprevalence. The author has an hindex of 2, co-authored 4 publications receiving 10 citations.

Papers
More filters
Journal ArticleDOI
TL;DR: In this paper, a lateral flow assay was used to identify specific IgM and IgG antibodies against SARS-CoV-2 and reported the seroprevalence estimates of these antibodies among health care workers and healthy volunteer blood donors in Panama.
Abstract: Novel severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is the etiologic agent of the ongoing coronavirus disease 2019 (COVID-19) pandemic, which has reached 28 million cases worldwide in 1 year. The serological detection of antibodies against the virus will play a pivotal role in complementing molecular tests to improve diagnostic accuracy, contact tracing, vaccine efficacy testing, and seroprevalence surveillance. Here, we aimed first to evaluate a lateral flow assay's ability to identify specific IgM and IgG antibodies against SARS-CoV-2 and second, to report the seroprevalence estimates of these antibodies among health care workers and healthy volunteer blood donors in Panama. We recruited study participants between April 30th and July 7th, 2020. For the test validation and performance evaluation, we analyzed serum samples from participants with clinical symptoms and confirmed positive RT-PCR for SARS-CoV-2, and a set of pre-pandemic serum samples. We used two by two table analysis to determine the test positive and negative percentage agreement as well as the Kappa agreement value with a 95% confidence interval. Then, we used the lateral flow assay to determine seroprevalence among serum samples from COVID-19 patients, potentially exposed health care workers, and healthy volunteer donors. Our results show this assay reached a positive percent agreement of 97.2% (95% CI 84.2-100.0%) for detecting both IgM and IgG. The assay showed a Kappa of 0.898 (95%CI 0.811-0.985) and 0.918 (95% CI 0.839-0.997) for IgM and IgG, respectively. The evaluation of serum samples from hospitalized COVID-19 patients indicates a correlation between test sensitivity and the number of days since symptom onset; the highest positive percent agreement [87% (95% CI 67.0-96.3%)] was observed at ≥15 days post-symptom onset (PSO). We found an overall antibody seroprevalence of 11.6% (95% CI 8.5-15.8%) among both health care workers and healthy blood donors. Our findings suggest this lateral flow assay could contribute significantly to implementing seroprevalence testing in locations with active community transmission of SARS-CoV-2.

13 citations

Posted ContentDOI
10 Dec 2020-medRxiv
TL;DR: A lateral flow assay ability to identify specific IgM and IgG antibodies against SARS-CoV-2 and to report the seroprevalence of these antibodies among health care workers and healthy volunteer blood donors in Panama are evaluated.
Abstract: Novel severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is the etiologic agent of the ongoing coronavirus disease 2019 (COVID-19) pandemic, which has reached 28 million cases worldwide in eight months. The serological detection of antibodies against the virus will play a pivotal role in complementing molecular tests to improve diagnostic accuracy, contact tracing, vaccine efficacy testing and seroprevalence surveillance. Here, we aimed first to evaluate a lateral flow assay’s ability to identify specific IgM and IgG antibodies against SARS-CoV-2 and second, to report the seroprevalence of these antibodies among health care workers and healthy volunteer blood donors in Panama. We recruited study participants between April 30th and July 7th, 2020. For the test validation and performance evaluation, we analyzed serum samples from participants with clinical symptoms and confirmed positive RT-PCR for SARS-CoV-2, and a set of pre-pandemic serum samples. We used two by two table analysis to determine the test sensitivity and specificity as well as the kappa agreement value with a 95% confidence interval. Then, we used the lateral flow assay to determine seroprevalence among serum samples from COVID-19 patients, potentially exposed health care workers, and healthy volunteer donors. Our results show this assay reached a positive percent agreement of 97.2% (95% CI 84.2-100.0%) for detecting both IgM and IgG. The assay showed a kappa of 0.898 (95%CI 0.811-0.985) and 0.918 (95% CI 0.839-0.997) for IgM and IgG, respectively. The evaluation of serum samples from hospitalized COVID-19 patients indicates a correlation between test sensitivity and the number of days since symptom onset; the highest positive percent agreement (87% (95% CI 67.0-96.3%)) was observed at ≥15 days post-symptom onset. We found an overall antibody seroprevalence of 11.6% (95% CI 8.5-15.8%) among both health care workers and healthy blood donors. Our findings suggest this lateral flow assay could contribute significantly to implementing seroprevalence testing in locations with active community transmission of SARS-CoV-2.

11 citations

Journal ArticleDOI
14 Sep 2021-PLOS ONE
TL;DR: In this article, four ELISA assays were evaluated to measure the presence of IgG or IgM specific for the viral Spike protein in COVID-19 patients, using either the full recombinant SARS-CoV-2 Spike protein or the fragment corresponding to the receptor binding domain.
Abstract: COVID-19 is the name of the acute respiratory disease caused by the new coronavirus SARS-CoV-2, a close relative of those that caused the severe outbreaks of SARS and MERS several years ago. Since first appearance on December of 2019, the COVID-19 pandemic has cause extremely high levels of mortality, morbidity, global economic breakdown, and the consequent human suffering. The main diagnostic test for the confirmation of symptomatic individuals is the detection of viral RNA by reverse transcriptase-quantitative real time PCR (RT-PCR). Additionally, serology techniques, such as ELISA are useful to measure the antibodies produced in humans after contact with the virus, as well as the direct presence of viral antigens. In this study we aim to assemble and evaluate four ELISA assays to measure the presence of IgG or IgM specific for the viral Spike protein in COVID-19 patients, using either the full recombinant SARS-CoV-2 Spike protein or the fragment corresponding to the receptor binding domain. As a control, we analyzed a group of pre-pandemic serum samples obtained before 2017. Strong reactivity was observed against both antigens. A few pre-pandemic samples displayed high OD values, suggesting the possibility of some cross reactivity. All four assays show very good repeatability, both intra- and inter-assay. Receiver operating characteristic analysis allowed the definition of cutoffs and evaluation of performance for each ELISA by estimation of the area under the curve. This performance parameter was high for all tests (AUC range: 0.98-0.99). Multiple comparisons between tests revealed no significant difference between each other (P values: 0.24-0.95). Our results show that both antigens are effective to detect both specific IgG and IgM antibodies, with high sensitivity (range 0.92-0.99), specificity (range 0.93-0.97) and congruence with the RT-PCR test (Cohen´s Kappa range 0.87-0.93). These assays will allow health authorities to have a new tool to estimate seroprevalence, in order to manage and improve the severe sanitary situation caused by this virus.

6 citations

Posted ContentDOI
04 May 2021-medRxiv
TL;DR: In this article, the presence of SARS-CoV-2 Spike proteins was evaluated using four ELISA assays, and the results showed that both antigens are very effective to reveal both specific IgG and IgM antibodies, with high sensitivity and specificity.
Abstract: COVID-19 is the name of the acute respiratory disease caused by the new coronavirus SARS-CoV-2, a close relative of those that caused the severe outbreaks of SARS and MERS several years ago. Since first appearance on December of 2019, the COVID-19 pandemic has cause extremely high levels of mortality, morbidity, global economic breakdown and the consequent human suffering. While vaccination efforts are not extensive and rapid enough, the main tools to keep the virus under control are still keeping physical distancing, reinforce personal hygiene measures, using masks and early diagnosis of virus infected persons, either symptomatic or not. The main diagnostic test for the confirmation of symptomatic individuals is the detection of viral RNA by reverse transcriptase - quantitative real time PCR (RT-PCR). Additionally, serology techniques, such as ELISA are extremely useful to measure the antibodies generated in humans after virus contact, as well as the direct presence of viral antigens. In this study we aim to assemble and evaluate four ELISAs assays to measure the presence of IgG or IgM specific for the viral Spike protein in COVID-19 patients, using either the full recombinant SARS-CoV-2 Spike protein or the fragment corresponding to the receptor binding domain. As a control, we also analyzed a group of prepandemic serum samples obtained before 2017. Strong reactivity was observed against both antigens. A few prepandemic samples displayed high OD values, suggesting the possibility of some crossreactivity. All four assays show very good repeatability, both intra- and inter-assay; however, no clear relationship could be detected between positivity and time of sample collection for serology. Receiver operating characteristic analysis allowed the definition of cutoffs and evaluation of performance for each ELISA by estimation of the area under the curve. This performance parameter was high for all tests (AUC range: 0.98-0.995). Multiple comparisons between tests revealed no significant difference between each other (P values: 0.24-0.95). Our results show that both antigens are very effective to reveal both specific IgG and IgM antibodies, with high sensitivity (range 0.929-0.99) and specificity (range 0.933-0.977). The estimated congruence with the RT-PCR test, as estimated by Cohens Kappa, indicates a high agreement in all cases (range 0.874-0.937). This test will allow health authorities to have a new tool to estimate seroprevalence, and to manage and improve the serious sanitary situation created by this virus.

1 citations

Posted ContentDOI
10 Mar 2023-medRxiv
TL;DR: In this article , the diagnostic performance of a chemiluminescence enzyme immunoassay (CLIA) on a set of 1,035 samples including pre-pandemic samples, healthcare workers (HCW), blood donors (BD) and COVID-19 positive confirmed by RT-PCR collected from April to December 2020.
Abstract: Introduction: Serological detection of antibodies against SARS-CoV-2 has become an essential tool to test vaccine efficacy and epidemiological surveillance of COVID-19. There have been limited published studies documenting the performance of SARS-CoV-2 antibody assays within hispanic populations. Materials and methods: We evaluated the diagnostic performance of a chemiluminescence enzyme immunoassay (CLIA) on a set of 1,035 samples including pre-pandemic samples, healthcare workers (HCW), blood donors (BD) and COVID-19 positive confirmed by RT-PCR collected from April to December 2020. Results: Through a ROC curve the CLIA test had a high diagnostic performance, with an AUC of 0.9854 (CI95% 95.68-100), P<0.0001. The analysis yielded a cut-off point 0.1950, sensitivity of 98.4% (CI95% 95 91.54-99.9), and specificity of 93.8% (CI95% 79.8 - 98.9). The diagnostic performance was also evaluated comparing the results with those obtained using other diagnostic techniques. Substantial agreement with the lateral flow chromatography and RT-PCR tests was found, and a high level of agreement with ELISA, with %PPA of 91.3 (CI95% 84.0-95.5), %NPA of 97.7 (CI95% 96.3-98.6), %OPA of 97.7 (CI95% 96.3-98.6) and Cohens kappa value of 90.4 (CI95% 85.8-94.9). A logistic regression was used to determine which of the independent variables predicted reactivity to CLIA test. A higher age was associated with an odds ratio (OR) of 1.043 (CI95% 1.022-1.065), while the presence of at least one chronic disease was associated with an OR of 5.649 (CI95% 3.089-10.329) greater likelihood of reactivity. Conclusions: CLIA test exhibited excellent performance making it a suitable test for seroprevalence surveillance at the community level.

Cited by
More filters
Journal ArticleDOI
TL;DR: In this paper, a review of point-of-care-testing (POCT) analysis is presented, where the authors discuss the advantages and limitations of the conventional and clinical approaches.
Abstract: Viruses are responsible for multiple infections in humans that impose huge health burdens on individuals and populations worldwide. Therefore, numerous diagnostic methods and strategies have been developed for prevention, management, and decreasing the burden of viral diseases, each having its advantages and limitations. Viral infections are commonly detected using serological and nucleic acid-based methods. However, these conventional and clinical approaches have some limitations that can be resolved by implementing other detector devices. Therefore, the search for sensitive, selective, portable, and costless approaches as efficient alternative clinical methods for point of care testing (POCT) analysis has gained much attention in recent years. POCT is one of the ultimate goals in virus detection, and thus, the tests need to be rapid, specific, sensitive, accessible, and user-friendly. In this review, after a brief overview of viruses and their characteristics, the conventional viral detection methods, the clinical approaches, and their advantages and shortcomings are firstly explained. Then, LFA systems working principles, benefits, classification are discussed. Furthermore, the studies regarding designing and employing LFAs in diagnosing different types of viruses, especially SARS-CoV-2 as a main concern worldwide and innovations in the LFAs' approaches and designs, are comprehensively discussed here. Furthermore, several strategies addressed in some studies for overcoming LFA limitations like low sensitivity are reviewed. Numerous techniques are adopted to increase sensitivity and perform quantitative detection. Employing several visualization methods, using different labeling reporters, integrating LFAs with other detection methods to benefit from both LFA and the integrated detection device advantages, and designing unique membranes to increase reagent reactivity, are some of the approaches that are highlighted.

32 citations

Journal Article
24 Jun 2020
TL;DR: Concerns are expressed over aspects of the establishment of SARS-CoV-2 antibody testing in England and the performance of these assays has not yet been assessed to the standard typically required of a novel test.
Abstract: We are writing to express concerns over aspects of the establishment of SARS-CoV-2 antibody testing in England. NHS England and NHS Improvement wrote to NHS trusts and pathology networks on 25 May 2020, asking them to offer antibody testing at short notice and ramp up capacity to thousands of samples a day.12 We have three concerns about the request. Firstly, there is no specific clinical indication for the test on an individual basis. Secondly, the performance of these assays has not yet been assessed to the standard typically required of a novel test. And thirdly, the resource implications are not considered. We support the rapid provision of diagnostic tests for individual and public health and recognise the need to deliver at pace. It is essential, however, that quality systems, which have evolved over many years and are the foundation for delivering the right result of the right test to the right person at the right time, are not circumvented. In usual clinical practice, antibody testing fulfils several purposes. In acute illness, an IgM antibody response can be used to diagnose an infectious …

27 citations

Journal ArticleDOI
TL;DR: In this article , the authors evaluated the accuracy of serology tests to detect the presence of antibodies to SARS-CoV-2 infection and to detect cases of SARS•CoV•2 infection that were missed by earlier diagnostic tests.
Abstract: Background The diagnostic challenges associated with the COVID‐19 pandemic resulted in rapid development of diagnostic test methods for detecting SARS‐CoV‐2 infection. Serology tests to detect the presence of antibodies to SARS‐CoV‐2 enable detection of past infection and may detect cases of SARS‐CoV‐2 infection that were missed by earlier diagnostic tests. Understanding the diagnostic accuracy of serology tests for SARS‐CoV‐2 infection may enable development of effective diagnostic and management pathways, inform public health management decisions and understanding of SARS‐CoV‐2 epidemiology. Objectives To assess the accuracy of antibody tests, firstly, to determine if a person presenting in the community, or in primary or secondary care has current SARS‐CoV‐2 infection according to time after onset of infection and, secondly, to determine if a person has previously been infected with SARS‐CoV‐2. Sources of heterogeneity investigated included: timing of test, test method, SARS‐CoV‐2 antigen used, test brand, and reference standard for non‐SARS‐CoV‐2 cases. Search methods The COVID‐19 Open Access Project living evidence database from the University of Bern (which includes daily updates from PubMed and Embase and preprints from medRxiv and bioRxiv) was searched on 30 September 2020. We included additional publications from the Evidence for Policy and Practice Information and Co‐ordinating Centre (EPPI‐Centre) ‘COVID‐19: Living map of the evidence’ and the Norwegian Institute of Public Health ’NIPH systematic and living map on COVID‐19 evidence’. We did not apply language restrictions. Selection criteria We included test accuracy studies of any design that evaluated commercially produced serology tests, targeting IgG, IgM, IgA alone, or in combination. Studies must have provided data for sensitivity, that could be allocated to a predefined time period after onset of symptoms, or after a positive RT‐PCR test. Small studies with fewer than 25 SARS‐CoV‐2 infection cases were excluded. We included any reference standard to define the presence or absence of SARS‐CoV‐2 (including reverse transcription polymerase chain reaction tests (RT‐PCR), clinical diagnostic criteria, and pre‐pandemic samples). Data collection and analysis We use standard screening procedures with three reviewers. Quality assessment (using the QUADAS‐2 tool) and numeric study results were extracted independently by two people. Other study characteristics were extracted by one reviewer and checked by a second. We present sensitivity and specificity with 95% confidence intervals (CIs) for each test and, for meta‐analysis, we fitted univariate random‐effects logistic regression models for sensitivity by eligible time period and for specificity by reference standard group. Heterogeneity was investigated by including indicator variables in the random‐effects logistic regression models. We tabulated results by test manufacturer and summarised results for tests that were evaluated in 200 or more samples and that met a modification of UK Medicines and Healthcare products Regulatory Agency (MHRA) target performance criteria. Main results We included 178 separate studies (described in 177 study reports, with 45 as pre‐prints) providing 527 test evaluations. The studies included 64,688 samples including 25,724 from people with confirmed SARS‐CoV‐2; most compared the accuracy of two or more assays (102/178, 57%). Participants with confirmed SARS‐CoV‐2 infection were most commonly hospital inpatients (78/178, 44%), and pre‐pandemic samples were used by 45% (81/178) to estimate specificity. Over two‐thirds of studies recruited participants based on known SARS‐CoV‐2 infection status (123/178, 69%). All studies were conducted prior to the introduction of SARS‐CoV‐2 vaccines and present data for naturally acquired antibody responses. Seventy‐nine percent (141/178) of studies reported sensitivity by week after symptom onset and 66% (117/178) for convalescent phase infection. Studies evaluated enzyme‐linked immunosorbent assays (ELISA) (165/527; 31%), chemiluminescent assays (CLIA) (167/527; 32%) or lateral flow assays (LFA) (188/527; 36%). Risk of bias was high because of participant selection (172, 97%); application and interpretation of the index test (35, 20%); weaknesses in the reference standard (38, 21%); and issues related to participant flow and timing (148, 82%). We judged that there were high concerns about the applicability of the evidence related to participants in 170 (96%) studies, and about the applicability of the reference standard in 162 (91%) studies. Average sensitivities for current SARS‐CoV‐2 infection increased by week after onset for all target antibodies. Average sensitivity for the combination of either IgG or IgM was 41.1% in week one (95% CI 38.1 to 44.2; 103 evaluations; 3881 samples, 1593 cases), 74.9% in week two (95% CI 72.4 to 77.3; 96 evaluations, 3948 samples, 2904 cases) and 88.0% by week three after onset of symptoms (95% CI 86.3 to 89.5; 103 evaluations, 2929 samples, 2571 cases). Average sensitivity during the convalescent phase of infection (up to a maximum of 100 days since onset of symptoms, where reported) was 89.8% for IgG (95% CI 88.5 to 90.9; 253 evaluations, 16,846 samples, 14,183 cases), 92.9% for IgG or IgM combined (95% CI 91.0 to 94.4; 108 evaluations, 3571 samples, 3206 cases) and 94.3% for total antibodies (95% CI 92.8 to 95.5; 58 evaluations, 7063 samples, 6652 cases). Average sensitivities for IgM alone followed a similar pattern but were of a lower test accuracy in every time slot. Average specificities were consistently high and precise, particularly for pre‐pandemic samples which provide the least biased estimates of specificity (ranging from 98.6% for IgM to 99.8% for total antibodies). Subgroup analyses suggested small differences in sensitivity and specificity by test technology however heterogeneity in study results, timing of sample collection, and smaller sample numbers in some groups made comparisons difficult. For IgG, CLIAs were the most sensitive (convalescent‐phase infection) and specific (pre‐pandemic samples) compared to both ELISAs and LFAs (P < 0.001 for differences across test methods). The antigen(s) used (whether from the Spike‐protein or nucleocapsid) appeared to have some effect on average sensitivity in the first weeks after onset but there was no clear evidence of an effect during convalescent‐phase infection. Investigations of test performance by brand showed considerable variation in sensitivity between tests, and in results between studies evaluating the same test. For tests that were evaluated in 200 or more samples, the lower bound of the 95% CI for sensitivity was 90% or more for only a small number of tests (IgG, n = 5; IgG or IgM, n = 1; total antibodies, n = 4). More test brands met the MHRA minimum criteria for specificity of 98% or above (IgG, n = 16; IgG or IgM, n = 5; total antibodies, n = 7). Seven assays met the specified criteria for both sensitivity and specificity. In a low‐prevalence (2%) setting, where antibody testing is used to diagnose COVID‐19 in people with symptoms but who have had a negative PCR test, we would anticipate that 1 (1 to 2) case would be missed and 8 (5 to 15) would be falsely positive in 1000 people undergoing IgG or IgM testing in week three after onset of SARS‐CoV‐2 infection. In a seroprevalence survey, where prevalence of prior infection is 50%, we would anticipate that 51 (46 to 58) cases would be missed and 6 (5 to 7) would be falsely positive in 1000 people having IgG tests during the convalescent phase (21 to 100 days post‐symptom onset or post‐positive PCR) of SARS‐CoV‐2 infection. Authors' conclusions Some antibody tests could be a useful diagnostic tool for those in whom molecular‐ or antigen‐based tests have failed to detect the SARS‐CoV‐2 virus, including in those with ongoing symptoms of acute infection (from week three onwards) or those presenting with post‐acute sequelae of COVID‐19. However, antibody tests have an increasing likelihood of detecting an immune response to infection as time since onset of infection progresses and have demonstrated adequate performance for detection of prior infection for sero‐epidemiological purposes. The applicability of results for detection of vaccination‐induced antibodies is uncertain.

19 citations

Journal ArticleDOI
TL;DR: In this paper, a lateral flow assay was used to identify specific IgM and IgG antibodies against SARS-CoV-2 and reported the seroprevalence estimates of these antibodies among health care workers and healthy volunteer blood donors in Panama.
Abstract: Novel severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is the etiologic agent of the ongoing coronavirus disease 2019 (COVID-19) pandemic, which has reached 28 million cases worldwide in 1 year. The serological detection of antibodies against the virus will play a pivotal role in complementing molecular tests to improve diagnostic accuracy, contact tracing, vaccine efficacy testing, and seroprevalence surveillance. Here, we aimed first to evaluate a lateral flow assay's ability to identify specific IgM and IgG antibodies against SARS-CoV-2 and second, to report the seroprevalence estimates of these antibodies among health care workers and healthy volunteer blood donors in Panama. We recruited study participants between April 30th and July 7th, 2020. For the test validation and performance evaluation, we analyzed serum samples from participants with clinical symptoms and confirmed positive RT-PCR for SARS-CoV-2, and a set of pre-pandemic serum samples. We used two by two table analysis to determine the test positive and negative percentage agreement as well as the Kappa agreement value with a 95% confidence interval. Then, we used the lateral flow assay to determine seroprevalence among serum samples from COVID-19 patients, potentially exposed health care workers, and healthy volunteer donors. Our results show this assay reached a positive percent agreement of 97.2% (95% CI 84.2-100.0%) for detecting both IgM and IgG. The assay showed a Kappa of 0.898 (95%CI 0.811-0.985) and 0.918 (95% CI 0.839-0.997) for IgM and IgG, respectively. The evaluation of serum samples from hospitalized COVID-19 patients indicates a correlation between test sensitivity and the number of days since symptom onset; the highest positive percent agreement [87% (95% CI 67.0-96.3%)] was observed at ≥15 days post-symptom onset (PSO). We found an overall antibody seroprevalence of 11.6% (95% CI 8.5-15.8%) among both health care workers and healthy blood donors. Our findings suggest this lateral flow assay could contribute significantly to implementing seroprevalence testing in locations with active community transmission of SARS-CoV-2.

13 citations

Journal ArticleDOI
TL;DR: This study designed candidate stable immunogens that mimic surface features of selected conserved regions of spike protein through ‘epitope grafting,’ in which the target epitope topology is presented on diverse heterologous scaffolds that can structurally accommodate the spike epitopes.
Abstract: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) surface spike glycoprotein - a major antibody target - is critical for virus entry via engagement of human angiotensin-converting enzyme 2 (ACE2) receptor. Despite successes with existing vaccines and therapies that primarily target the receptor binding domain (RBD) of the spike protein, the susceptibility of RBD to mutations provides escape routes for the SARS-CoV-2 from neutralizing antibodies. On the other hand, structural conservation in the spike protein can be targeted to reduce escape mutations and achieve broad protection. Here, we designed candidate stable immunogens that mimic surface features of selected conserved regions of spike protein through ‘epitope grafting,’ in which we present the target epitope topology on diverse heterologous scaffolds that can structurally accommodate the spike epitopes. Structural characterization of the epitope-scaffolds showed stark agreement with our computational models and target epitopes. The sera from mice immunized with engineered designs display epitope-scaffolds and spike binding activity. We also demonstrated the utility of the designed epitope-scaffolds in diagnostic applications. Taken all together, our study provides important methodology for targeting the conserved, non-RBD structural motifs of spike protein for SARS-CoV-2 epitope vaccine design and demonstrates the potential utility of ‘epitope grafting’ in rational vaccine design.

8 citations