Author
H. Mehta
Bio: H. Mehta is an academic researcher from Westinghouse Electric. The author has contributed to research in topics: Static VAR compensator & AC power. The author has an hindex of 1, co-authored 1 publications receiving 955 citations.
Papers
More filters
••
01 Jul 1993TL;DR: In this paper, two fundamentally different types of invertor can be used for this purpose, one providing control of output voltage magnitude and phase angle, and the other having only phase angle control.
Abstract: The advanced static Var compensator (now widely known as the static condenser or STATCON) uses a high power self-commutating inverter to draw reactive current from a transmission line. Two fundamentally different types of invertor can be used for this purpose, one providing control of output voltage magnitude and phase angle, and the other having only phase angle control. For each of these types, the governing equations are derived, and frequency domain analysis is used to obtain the relevant transfer functions for control system synthesis. Further analysis is provided to determine the response of the STATCON to negative sequence and harmonic voltage components on the transmission line. The results are illustrated with measured waveforms obtained from a scaled analogue model of an 80 MVAr STATCON.<
>
974 citations
Cited by
More filters
••
TL;DR: This paper presents a comprehensive review of active filter configurations, control strategies, selection of components, other related economic and technical considerations, and their selection for specific applications.
Abstract: Active filtering of electric power has now become a mature technology for harmonic and reactive power compensation in two-wire (single phase), three-wire (three phase without neutral), and four-wire (three phase with neutral) AC power networks with nonlinear loads. This paper presents a comprehensive review of active filter (AF) configurations, control strategies, selection of components, other related economic and technical considerations, and their selection for specific applications. It is aimed at providing a broad perspective on the status of AF technology to researchers and application engineers dealing with power quality issues. A list of more than 200 research publications on the subject is also appended for a quick reference.
2,311 citations
••
TL;DR: In this article, real and reactive power management strategies of EI-DG units in the context of a multiple DG microgrid system were investigated. And the results were used to discuss applications under various microgrid operating conditions.
Abstract: This paper addresses real and reactive power management strategies of electronically interfaced distributed generation (DG) units in the context of a multiple-DG microgrid system. The emphasis is primarily on electronically interfaced DG (EI-DG) units. DG controls and power management strategies are based on locally measured signals without communications. Based on the reactive power controls adopted, three power management strategies are identified and investigated. These strategies are based on 1) voltage-droop characteristic, 2) voltage regulation, and 3) load reactive power compensation. The real power of each DG unit is controlled based on a frequency-droop characteristic and a complimentary frequency restoration strategy. A systematic approach to develop a small-signal dynamic model of a multiple-DG microgrid, including real and reactive power management strategies, is also presented. The microgrid eigen structure, based on the developed model, is used to 1) investigate the microgrid dynamic behavior, 2) select control parameters of DG units, and 3) incorporate power management strategies in the DG controllers. The model is also used to investigate sensitivity of the design to changes of parameters and operating point and to optimize performance of the microgrid system. The results are used to discuss applications of the proposed power management strategies under various microgrid operating conditions
1,531 citations
••
TL;DR: In this paper, the authors investigated preplanned switching events and fault events that lead to islanding of a distribution subsystem and formation of a micro-grid, and they concluded that an appropriate control strategy for the power electronically interfaced DG unit can ensure stability of the microgrid and maintain voltage quality at designated buses, even during islanding transients.
Abstract: This paper investigates (i) preplanned switching events and (ii) fault events that lead to islanding of a distribution subsystem and formation of a micro-grid. The micro-grid includes two distributed generation (DG) units. One unit is a conventional rotating synchronous machine and the other is interfaced through a power electronic converter. The interface converter of the latter unit is equipped with independent real and reactive power control to minimize islanding transients and maintain both angle stability and voltage quality within the micro-grid. The studies are performed based on a digital computer simulation approach using the PSCAD/EMTDC software package. The studies show that an appropriate control strategy for the power electronically interfaced DG unit can ensure stability of the micro-grid and maintain voltage quality at designated buses, even during islanding transients. This paper concludes that presence of an electronically-interfaced DG unit makes the concept of micro-grid a technically viable option for further investigations.
1,136 citations
••
TL;DR: In this paper, the authors proposed a unified power flow controller (UPFC) that is able to control both the transmitted real power and, independently, the reactive power flows at the sending-and the receiving-end of the transmission line.
Abstract: This paper shows that the unified power flow controller (UPFC) is able to control both the transmitted real power and, independently, the reactive power flows at the sending- and the receiving-end of the transmission line. The unique capabilities of the UPFC in multiple line compensation are integrated into a generalized power flow controller that is able to maintain prescribed, and independently controllable, real power and reactive power flow in the line. The paper describes the basic concepts of the proposed generalized P and Q controller and compares it to the more conventional, but related power flow controllers, such as the thyristor-controlled series capacitor and thyristor-controlled phase angle regulator. The paper also presents results of computer simulations showing the performance of the UPFC under different system conditions. >
997 citations
••
TL;DR: In this article, a doubly-fed induction generator (DFIG)-based wind generation system operating under unbalanced network conditions is analyzed and control design of a DFIG system model in the positive and negative synchronous reference frames is presented.
Abstract: This paper presents an analysis and control design of a doubly-fed induction generator (DFIG)-based wind generation system operating under unbalanced network conditions. A DFIG system model in the positive and negative synchronous reference frames is presented. Variations of stator active and reactive powers and generator torque are fully defined in the presence of negative sequence voltage and current. Alternative DFIG control targets during network unbalance, such as reducing stator current unbalance, torque, and power pulsations minimization, are identified. A rotor current control strategy based on positive and negative (dq) reference frames is used to provide precise control of the rotor positive and negative sequence currents. Simulation results using EMTDC/PSCAD are presented for a 2-MW DFIG wind generation system. It shows that conventional vector control of DFIG without considering network unbalance results in excessive oscillations on the stator active/reactive power, electromagnetic torque, and stator/rotor currents even with a small stator voltage unbalance. In contrast, with the proposed control strategy, enhanced system control and operation such as minimizing oscillations in either active power, or electromagnetic torque, or stator or rotor currents can be achieved
617 citations