Author
Helena G. Ramos
Other affiliations: ALFA, Technical University of Lisbon, University of Lisbon
Bio: Helena G. Ramos is an academic researcher from Instituto Superior Técnico. The author has contributed to research in topics: Eddy current & Eddy-current testing. The author has an hindex of 18, co-authored 122 publications receiving 1092 citations. Previous affiliations of Helena G. Ramos include ALFA & Technical University of Lisbon.
Papers published on a yearly basis
Papers
More filters
TL;DR: The Post-hospitalisation COVID-19 study (PHOSP-COVID) as mentioned in this paper is a prospective, longitudinal cohort study recruiting adults (aged ≥18 years) discharged from hospital with COVID19 across the UK.
Abstract: BackgroundNo effective pharmacological or non-pharmacological interventions exist for patients with long COVID. We aimed to describe recovery 1 year after hospital discharge for COVID-19, identify factors associated with patient-perceived recovery, and identify potential therapeutic targets by describing the underlying inflammatory profiles of the previously described recovery clusters at 5 months after hospital discharge.MethodsThe Post-hospitalisation COVID-19 study (PHOSP-COVID) is a prospective, longitudinal cohort study recruiting adults (aged ≥18 years) discharged from hospital with COVID-19 across the UK. Recovery was assessed using patient-reported outcome measures, physical performance, and organ function at 5 months and 1 year after hospital discharge, and stratified by both patient-perceived recovery and recovery cluster. Hierarchical logistic regression modelling was performed for patient-perceived recovery at 1 year. Cluster analysis was done using the clustering large applications k-medoids approach using clinical outcomes at 5 months. Inflammatory protein profiling was analysed from plasma at the 5-month visit. This study is registered on the ISRCTN Registry, ISRCTN10980107, and recruitment is ongoing.Findings2320 participants discharged from hospital between March 7, 2020, and April 18, 2021, were assessed at 5 months after discharge and 807 (32·7%) participants completed both the 5-month and 1-year visits. 279 (35·6%) of these 807 patients were women and 505 (64·4%) were men, with a mean age of 58·7 (SD 12·5) years, and 224 (27·8%) had received invasive mechanical ventilation (WHO class 7–9). The proportion of patients reporting full recovery was unchanged between 5 months (501 [25·5%] of 1965) and 1 year (232 [28·9%] of 804). Factors associated with being less likely to report full recovery at 1 year were female sex (odds ratio 0·68 [95% CI 0·46–0·99]), obesity (0·50 [0·34–0·74]) and invasive mechanical ventilation (0·42 [0·23–0·76]). Cluster analysis (n=1636) corroborated the previously reported four clusters: very severe, severe, moderate with cognitive impairment, and mild, relating to the severity of physical health, mental health, and cognitive impairment at 5 months. We found increased inflammatory mediators of tissue damage and repair in both the very severe and the moderate with cognitive impairment clusters compared with the mild cluster, including IL-6 concentration, which was increased in both comparisons (n=626 participants). We found a substantial deficit in median EQ-5D-5L utility index from before COVID-19 (retrospective assessment; 0·88 [IQR 0·74–1·00]), at 5 months (0·74 [0·64–0·88]) to 1 year (0·75 [0·62–0·88]), with minimal improvements across all outcome measures at 1 year after discharge in the whole cohort and within each of the four clusters.InterpretationThe sequelae of a hospital admission with COVID-19 were substantial 1 year after discharge across a range of health domains, with the minority in our cohort feeling fully recovered. Patient-perceived health-related quality of life was reduced at 1 year compared with before hospital admission. Systematic inflammation and obesity are potential treatable traits that warrant further investigation in clinical trials.FundingUK Research and Innovation and National Institute for Health Research. No effective pharmacological or non-pharmacological interventions exist for patients with long COVID. We aimed to describe recovery 1 year after hospital discharge for COVID-19, identify factors associated with patient-perceived recovery, and identify potential therapeutic targets by describing the underlying inflammatory profiles of the previously described recovery clusters at 5 months after hospital discharge. The Post-hospitalisation COVID-19 study (PHOSP-COVID) is a prospective, longitudinal cohort study recruiting adults (aged ≥18 years) discharged from hospital with COVID-19 across the UK. Recovery was assessed using patient-reported outcome measures, physical performance, and organ function at 5 months and 1 year after hospital discharge, and stratified by both patient-perceived recovery and recovery cluster. Hierarchical logistic regression modelling was performed for patient-perceived recovery at 1 year. Cluster analysis was done using the clustering large applications k-medoids approach using clinical outcomes at 5 months. Inflammatory protein profiling was analysed from plasma at the 5-month visit. This study is registered on the ISRCTN Registry, ISRCTN10980107, and recruitment is ongoing. 2320 participants discharged from hospital between March 7, 2020, and April 18, 2021, were assessed at 5 months after discharge and 807 (32·7%) participants completed both the 5-month and 1-year visits. 279 (35·6%) of these 807 patients were women and 505 (64·4%) were men, with a mean age of 58·7 (SD 12·5) years, and 224 (27·8%) had received invasive mechanical ventilation (WHO class 7–9). The proportion of patients reporting full recovery was unchanged between 5 months (501 [25·5%] of 1965) and 1 year (232 [28·9%] of 804). Factors associated with being less likely to report full recovery at 1 year were female sex (odds ratio 0·68 [95% CI 0·46–0·99]), obesity (0·50 [0·34–0·74]) and invasive mechanical ventilation (0·42 [0·23–0·76]). Cluster analysis (n=1636) corroborated the previously reported four clusters: very severe, severe, moderate with cognitive impairment, and mild, relating to the severity of physical health, mental health, and cognitive impairment at 5 months. We found increased inflammatory mediators of tissue damage and repair in both the very severe and the moderate with cognitive impairment clusters compared with the mild cluster, including IL-6 concentration, which was increased in both comparisons (n=626 participants). We found a substantial deficit in median EQ-5D-5L utility index from before COVID-19 (retrospective assessment; 0·88 [IQR 0·74–1·00]), at 5 months (0·74 [0·64–0·88]) to 1 year (0·75 [0·62–0·88]), with minimal improvements across all outcome measures at 1 year after discharge in the whole cohort and within each of the four clusters. The sequelae of a hospital admission with COVID-19 were substantial 1 year after discharge across a range of health domains, with the minority in our cohort feeling fully recovered. Patient-perceived health-related quality of life was reduced at 1 year compared with before hospital admission. Systematic inflammation and obesity are potential treatable traits that warrant further investigation in clinical trials.
118 citations
TL;DR: The main advantages of the proposed conductivity sensor include a wide measurement range, an intrinsic capability to minimize errors caused by fouling and polarization effects, and an automatic compensation of conductivity measurements caused by temperature variations.
Abstract: In this paper, a new four-electrode sensor for water conductivity measurements is presented. In addition to the sensor itself, all signal conditioning is implemented together with signal processing of the sensor outputs to determine the water conductivity. The sensor is designed for conductivity measurements in the range from 50 mS/m up to 5 S/m through the correct placement of the four electrodes inside the tube where the water flows. The implemented prototype is capable of supplying the sensor with the necessary current at the measurement frequency, acquiring the sine signals across the voltage electrodes of the sensor and across a sampling impedance to determine the current. A temperature sensor is also included in the system to measure the water temperature and, thus, compensate the water-conductivity temperature dependence. The main advantages of the proposed conductivity sensor include a wide measurement range, an intrinsic capability to minimize errors caused by fouling and polarization effects, and an automatic compensation of conductivity measurements caused by temperature variations.
83 citations
TL;DR: A linear transformer model is used to investigate the effect of the lift-off on the results of the thickness measurement of nonferromagnetic metallic plates and the similarity of the theoretical model results and those obtain experimentally with pulsed excitation confirms the correctness of the transformer approach.
Abstract: This paper uses a linear transformer model to investigate the effect of the lift-off on the results of the thickness measurement of nonferromagnetic metallic plates. The transformer model previews that the time derivative of the magnetization curves obtained for different gaps between the excitation coil and the plate should intercept in a single point when low magnetic coupling factors are considered. To assess the validity of the model, results are compared with experimental data obtained with a giant magnetoresistive sensor probe. For comparison, the sensor output voltage time derivative must be performed as well. The similarity of the theoretical model results and those obtain experimentally with pulsed excitation, confirms the correctness of the transformer approach.
74 citations
20 May 2003
TL;DR: This work was developed in the context of a system for remote water quality monitoring based on a wireless local area network (WLAN) and includes a Kohonen self-organizing map (K-SOM) implementation in order to perform sensor data validation and reconstruction and sensor failure and pollution event detections.
Abstract: This work was developed in the context of a system for remote water quality monitoring based on a wireless local area network (WLAN) and includes a Kohonen self-organizing map (K-SOM) implementation in order to perform sensor data validation and reconstruction and sensor failure and pollution event detections. Simulation and experimental results are presented.
47 citations
TL;DR: In this article, an enhancement in the probes to be used on a new nondestructive testing method with eddy currents induced by velocity was presented, in which a permanent magnet that is attached to a moving carriage creates eddy current in the conductive material to be inspected.
Abstract: This paper presents an enhancement in the probes to be used on a new nondestructive testing method with eddy currents induced by velocity. In this method, a permanent magnet that is attached to a moving carriage creates eddy currents in the conductive material to be inspected. By measuring the opposing magnetic field generated by the eddy currents, it is possible to obtain information regarding the presence of defects. Different magnetic field sensors, such as, differential pick-up coils, giant magneto resistors (GMR) and Hall sensors have been used and compared. A permanent magnet moving above a plate was studied using a numerical model to allow further improvements to be made in the probe. Depending on each sensor's geometry, sensing axis and range, its position and orientation must be strategically chosen in order to increase defect sensitivity. The best probe's position is the one that guarantees the highest sensibility to the defects’ presence.
46 citations
Cited by
More filters
31 Oct 2001
TL;DR: The American Society for Testing and Materials (ASTM) as mentioned in this paper is an independent organization devoted to the development of standards for testing and materials, and is a member of IEEE 802.11.
Abstract: The American Society for Testing and Materials (ASTM) is an independent organization devoted to the development of standards.
3,792 citations
TL;DR: An overview of the fundamentals and main variables of eddy current testing is included, and the state-of-the-art sensors and modern techniques such as multi-frequency and pulsed systems are described.
Abstract: Non-destructive techniques are used widely in the metal industry in order to control the quality of materials. Eddy current testing is one of the most extensively used non-destructive techniques for inspecting electrically conductive materials at very high speeds that does not require any contact between the test piece and the sensor. This paper includes an overview of the fundamentals and main variables of eddy current testing. It also describes the state-of-the-art sensors and modern techniques such as multi-frequency and pulsed systems. Recent advances in complex models towards solving crack-sensor interaction, developments in instrumentation due to advances in electronic devices, and the evolution of data processing suggest that eddy current testing systems will be increasingly used in the future.
683 citations
TL;DR: The current state of the art of plastic optical fiber technology will be reviewed, namely its main characteristics and sensing advantages, and the potential applications involving structural health monitoring, medicine, environment and the biological and chemical area are presented.
Abstract: The recent advances of polymer technology allowed the introduction of plastic optical fiber in sensor design. The advantages of optical metrology with plastic optical fiber have attracted the attention of the scientific community, as they allow the development of low-cost or cost competitive systems compared with conventional technologies. In this paper, the current state of the art of plastic optical fiber technology will be reviewed, namely its main characteristics and sensing advantages. Several measurement techniques will be described, with a strong focus on interrogation approaches based on intensity variation in transmission and reflection. The potential applications involving structural health monitoring, medicine, environment and the biological and chemical area are also presented.
294 citations
TL;DR: This paper describes work that has been done on design and development of a water quality monitoring system, with the objective of notifying the user of the real-time water quality parameters.
Abstract: This paper describes work that has been done on design and development of a water quality monitoring system, with the objective of notifying the user of the real-time water quality parameters. The system is able to measure the physiochemical parameters of water quality, such as flow, temperature, pH, conductivity, and the oxidation reduction potential. These physiochemical parameters are used to detect water contaminants. The sensors, which are designed from first principles and implemented with signal conditioning circuits, are connected to a microcontroller-based measuring node, which processes and analyzes the data. In this design, ZigBee receiver and transmitter modules are used for communication between the measuring and notification nodes. The notification node presents the reading of the sensors and outputs an audio alert when water quality parameters reach unsafe levels. Various qualification tests are run to validate each aspect of the monitoring system. The sensors are shown to work within their intended accuracy ranges. The measurement node is able to transmit data by ZigBee to the notification node for audio and visual display. The results demonstrate that the system is capable of reading physiochemical parameters, and can successfully process, transmit, and display the readings.
195 citations