scispace - formally typeset
Search or ask a question
Author

Hinnerk Schulz-Hildebrandt

Bio: Hinnerk Schulz-Hildebrandt is an academic researcher from University of Lübeck. The author has contributed to research in topics: Optical coherence tomography & Medicine. The author has an hindex of 8, co-authored 35 publications receiving 188 citations.

Papers
More filters
Journal ArticleDOI
TL;DR: The accuracies of the 3D shape sensing model are promising, and it is planned to combine the shape sensing based on fiber Bragg gratings with the position and orientation of an electromagnetic tracking to obtain the located catheter shape.
Abstract: Endovascular aortic repair procedures are currently conducted with 2D fluoroscopy imaging. Tracking systems based on fiber Bragg gratings are an emerging technology for the navigation of minimally invasive instruments which can reduce the X-ray exposure and the used contrast agent. Shape sensing of flexible structures is challenging and includes many calculations steps which are prone to different errors. To reduce this errors, we present an optimized shape sensing model. We analyzed for every step of the shape sensing process, which errors can occur, how the error affects the shape and how it can be compensated or minimized. Experiments were done with one multicore fiber system with 38 cm sensing length, and the effects of different methods and parameters were analyzed. Furthermore, we compared 3D shape reconstructions with the segmented shape of the corresponding CT scans of the fiber to evaluate the accuracy of our optimized shape sensing model. Finally, we tested our model in a realistic endovascular scenario by using a 3D printed vessel system created from patient data. Depending on the complexity of the shape, we reached an average error of 0.35–1.15 mm and maximal error of 0.75–7.53 mm over the whole 38 cm sensing length. In the endovascular scenario, we obtained an average and maximal error of 1.13 mm and 2.11 mm, respectively. The accuracies of the 3D shape sensing model are promising, and we plan to combine the shape sensing based on fiber Bragg gratings with the position and orientation of an electromagnetic tracking to obtain the located catheter shape.

58 citations

Journal ArticleDOI
TL;DR: Corneal lymphatic vessels can be imaged using microscopic optical coherence tomography (mOCT) and this novel approach opens new options for noninvasive clinical imaging of cornealymphatic vessels for diagnostic and therapeutic indications.
Abstract: Purpose Corneal neovascularization, in particular lymphangiogenesis, is a limiting factor in corneal transplant survival. Novel treatment approaches focus on (selective) inhibition and regression of lymphatic vessels. Imaging clinically invisible corneal lymphatic vessels is a prerequisite for these strategies. Using a murine model, this study investigates whether corneal lymphatic vessels can be imaged using microscopic optical coherence tomography (mOCT). Methods Corneal neovascularization was induced by intrastromal placement of 11.0 nylon sutures in one eye of BALB/c mice. After 2 weeks, cross-sectional images and volumes of the corneas with a 0.5 mm lateral and axial field of view were acquired using a custom-built mOCT system enabling a resolution of 1 μm at a B-scan rate of 165/s. Three of the six animals received an additional intrastromal injection of India ink 24 hours before the measurement to stain the corneal lymphatic system in vivo. Immunohistochemistry using CD31 and LYVE-1 was used to validate the mOCT findings. Results Using mOCT, lymphatic vessels were visible as dark vessel-like structures with the lumen lacking a hyperreflective wall and mostly lacking cells. However, individual, slowly moving particles, which most likely are immune cells, occasionally could be observed inside the lumen. In lymphatic vessels of ink-stained corneas, hyperreflection and shadowing underneath was observed. Ink-filled lymphatic vessels were colocalized in consecutive corneal flat mounts of the same specimen. Conclusions Corneal lymphatic vessels can be imaged using mOCT. This novel approach opens new options for noninvasive clinical imaging of corneal lymphatic vessels for diagnostic and therapeutic indications.

34 citations

Journal ArticleDOI
TL;DR: In this article, the authors demonstrate dynamic contrast with a scanning frequency-domain OCT (FD-OCT), which is a promising tool for the histological analysis of unstained tissues.
Abstract: While optical coherence tomography (OCT) provides a resolution down to 1 µm, it has difficulties in visualizing cellular structures due to a lack of scattering contrast. By evaluating signal fluctuations, a significant contrast enhancement was demonstrated using time-domain full-field OCT (FF-OCT), which makes cellular and subcellular structures visible. The putative cause of the dynamic OCT signal is the site-dependent active motion of cellular structures in a sub-micrometer range, which provides histology-like contrast. Here we demonstrate dynamic contrast with a scanning frequency-domain OCT (FD-OCT), which we believe has crucial advantages. Given the inherent sectional imaging geometry, scanning FD-OCT provides depth-resolved images across tissue layers, a perspective known from histopathology, much faster and more efficiently than FF-OCT. Both shorter acquisition times and tomographic depth-sectioning reduce the sensitivity of dynamic contrast for bulk tissue motion artifacts and simplify their correction in post-processing. Dynamic contrast makes microscopic FD-OCT a promising tool for the histological analysis of unstained tissues.

30 citations

Journal ArticleDOI
TL;DR: Endo-microscopic OCT (emOCT) is presented, which may be used for in-vivo imaging of lung diseases like cystic fibrosis or primary ciliary dyskinesia, which manifest already at the nasal mucosa and may considerably improve clinical diagnosis.
Abstract: Intravital microscopy (IVM) offers the opportunity to visualize static and dynamic changes of tissue on a cellular level. It is a valuable tool in research and may considerably improve clinical diagnosis. In contrast to confocal and non-linear microscopy, optical coherence tomography (OCT) with microscopic resolution (mOCT) provides intrinsically cross-sectional imaging. Changing focus position is not needed, which simplifies especially endoscopic imaging. For in-vivo imaging, here we are presenting endo-microscopic OCT (emOCT). A graded-index-lens (GRIN) based 2.75 mm outer diameter rigid endoscope is providing 1.5 – 2 µm nearly isotropic resolution over an extended field of depth. Spherical and chromatic aberrations are used to elongate the focus length. Simulation of the OCT image formation, suggests a better overall image quality in this range compared to a focused Gaussian beam. Total imaging depth at a reduced sensitivity and lateral resolution is more than 200 µm. Using a frame rate of 80 Hz cross-sectional images of concha nasalis were demonstrated in humans, which could resolve cilial motion, cellular structures of the epithelium, vessels and blood cells. Mucus transport velocity was successfully determined. The endoscope may be used for diagnosis and treatment control of different lung diseases like cystic fibrosis or primary ciliary dyskinesia, which manifest already at the nasal mucosa.

29 citations

Journal ArticleDOI
TL;DR: The development of a combined force and distance sensing cannulation needle, and its experimental validation during in vivo animal trials, demonstrate the feasibility of deploying a combined sensing instrument in an in vivo setting.
Abstract: Retinal vein cannulation is an experimental procedure during which a clot-dissolving drug is injected into an obstructed retinal vein. However, due to the fragility and minute size of retinal veins, such procedure is considered too risky to perform manually. With the aid of surgical robots, key limiting factors such as: unwanted eye rotations, hand tremor and instrument immobilization can be tackled. However, local instrument anatomy distance and force estimation remain unresolved issues. A reliable, real-time local interaction estimation between instrument tip and the retina could be a solution. This paper reports on the development of a combined force and distance sensing cannulation needle, and its experimental validation during in vivo animal trials. Two prototypes are reported, relying on force and distance measurements based on FBG and OCT A-scan fibres, respectively. Both instruments provide an 80 $$\upmu \hbox {m}$$ needle tip and have outer shaft diameters of 0.6 and 2.3 mm, respectively. Both prototypes were characterized and experimentally validated ex vivo. Then, paired with a previously developed surgical robot, in vivo experimental validation was performed. The first prototype successfully demonstrated the feasibility of using a combined force and distance sensing instrument in an in vivo setting. The results demonstrate the feasibility of deploying a combined sensing instrument in an in vivo setting. The performed study provides a foundation for further work on real-time local modelling of the surgical scene. This paper provides initial insights; however, additional processing remains necessary.

25 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: Computer and Robot Vision Vol.
Abstract: Computer and Robot Vision Vol. 1, by R.M. Haralick and Linda G. Shapiro, Addison-Wesley, 1992, ISBN 0-201-10887-1.

1,426 citations

Journal Article
TL;DR: In this article, optical coherence tomography was adapted to allow high-speed visualization of tissue in a living animal with a catheter-endoscope 1 millimeter in diameter, which was used to obtain cross-sectional images of the rabbit gastrointestinal and respiratory tracts at 10-micrometer resolution.
Abstract: Current medical imaging technologies allow visualization of tissue anatomy in the human body at resolutions ranging from 100 micrometers to 1 millimeter. These technologies are generally not sensitive enough to detect early-stage tissue abnormalities associated with diseases such as cancer and atherosclerosis, which require micrometer-scale resolution. Here, optical coherence tomography was adapted to allow high-speed visualization of tissue in a living animal with a catheter-endoscope 1 millimeter in diameter. This method, referred to as "optical biopsy," was used to obtain cross-sectional images of the rabbit gastrointestinal and respiratory tracts at 10-micrometer resolution.

1,285 citations

Journal ArticleDOI
TL;DR: The review of clinical applications of endoscopic OCT focuses heavily on diagnosis of diseases and guidance of interventions, and key design and engineering considerations are discussed for most OCT endoscopes, including side-viewing and forward-Viewing probes, along with different scanning mechanisms.
Abstract: In this paper, we review the current state of technology development and clinical applications of endoscopic optical coherence tomography (OCT). Key design and engineering considerations are discussed for most OCT endoscopes, including side-viewing and forward-viewing probes, along with different scanning mechanisms (proximal-scanning versus distal-scanning). Multi-modal endoscopes that integrate OCT with other imaging modalities are also discussed. The review of clinical applications of endoscopic OCT focuses heavily on diagnosis of diseases and guidance of interventions. Representative applications in several organ systems are presented, such as in the cardiovascular, digestive, respiratory, and reproductive systems. A brief outlook of the field of endoscopic OCT is also discussed.

186 citations

Journal ArticleDOI
TL;DR: Fiber Bragg grating has embraced the area of fiber optics since the early days of its discovery, and most fiber optic sensor systems today make use of fiber Bragg-grating technology as discussed by the authors.
Abstract: Fiber Bragg grating has embraced the area of fiber optics since the early days of its discovery, and most fiber optic sensor systems today make use of fiber Bragg grating technology Researchers have gained enormous attention in the field of fiber Bragg grating (FBG)-based sensing due to its inherent advantages, such as small size, fast response, distributed sensing, and immunity to the electromagnetic field Fiber Bragg grating technology is popularly used in measurements of various physical parameters, such as pressure, temperature, and strain for civil engineering, industrial engineering, military, maritime, and aerospace applications Nowadays, strong emphasis is given to structure health monitoring of various engineering and civil structures, which can be easily achieved with FBG-based sensors Depending on the type of grating, FBG can be uniform, long, chirped, tilted or phase shifted having periodic perturbation of refractive index inside core of the optical fiber Basic fundamentals of FBG and recent progress of fiber Bragg grating-based sensors used in various applications for temperature, pressure, liquid level, strain, and refractive index sensing have been reviewed A major problem of temperature cross sensitivity that occurs in FBG-based sensing requires temperature compensation technique that has also been discussed in this paper

163 citations

Journal ArticleDOI
TL;DR: The FBG-based measuring systems, their principle of work, and their applications in medicine and healthcare are reviewed to highlight how FBGs can meet the demands of next-generation medical devices and healthcare system.
Abstract: In the last decades, fiber Bragg gratings (FBGs) have become increasingly attractive to medical applications due to their unique properties such as small size, biocompatibility, immunity to electromagnetic interferences, high sensitivity and multiplexing capability. FBGs have been employed in the development of surgical tools, assistive devices, wearables, and biosensors, showing great potentialities for medical uses. This paper reviews the FBG-based measuring systems, their principle of work, and their applications in medicine and healthcare. Particular attention is given to sensing solutions for biomechanics, minimally invasive surgery, physiological monitoring, and medical biosensing. Strengths, weaknesses, open challenges, and future trends are also discussed to highlight how FBGs can meet the demands of next-generation medical devices and healthcare system.

157 citations