scispace - formally typeset
Search or ask a question
Author

Hongmei Wen

Bio: Hongmei Wen is an academic researcher from Nanjing University of Chinese Medicine. The author has contributed to research in topics: Medicine & Chemistry. The author has an hindex of 9, co-authored 52 publications receiving 312 citations.


Papers
More filters
Journal ArticleDOI
TL;DR: A silver nanoparticles-enhanced time-resolved fluorescence (TR-FL) sensor based on long-lived fluorescent Mn-doped ZnS quantum dots (QDs) is developed for the sensitive detection of vascular endothelial growth factor-165 (VEGF165), a predominant cancer biomarker in cancer angiogenesis.

43 citations

Journal ArticleDOI
TL;DR: An accurate and precise LC-MS/MS method was developed and applied successfully in a pharmacokinetic study and the resulting oral fucoxanthin bioavailability calculated.
Abstract: Fucoxanthin and its deacetylated metabolite fucoxanthinol are two major carotenoids that have been confirmed to possess various pharmacological properties. In the present study, fucoxanthinol was identified as the deacetylated metabolite of fucoxanthin, after intravenous (i.v.) and intragastric gavage (i.g.) administration to rats at doses of 2 and 65 mg/kg, respectively, by liquid chromatography-tandem mass spectrometric (LC-MS/MS) analysis. Next, an accurate and precise LC-MS/MS method was developed to quantitatively determine fucoxanthin and fucoxanthinol in rat plasma. Plasma samples were resolved by LC-MS/MS on a reverse-phase SB-C18 column that was equilibrated and eluted with acetonitrile (A)/aqueous 0.1% formic acid (B; 92/8, v/v) at a flow rate of 0.5 mL/min. Analytes were monitored by multiple-reaction monitoring (MRM) under positive electrospray ionization mode. The precursor/product transitions (m/z) were 659.3→109.0 for fucoxanthin, 617.2→109.0 for fucoxanthinol, and 429.4→313.2 for the internal standard (IS). Calibration curves for fucoxanthin and fucoxanthinol were linear over concentrations ranging from 1.53 to 720 and 1.17 to 600 ng/mL, respectively. The inter- and intraday accuracy and precision were within ±15%. The method was applied successfully in a pharmacokinetic study and the resulting oral fucoxanthin bioavailability calculated.

33 citations

Journal ArticleDOI
TL;DR: Eight sulfur‐containing/dehydrated‐integrated atractylenolides that evolved from the NF‐AMK were screened out as potential characteristic chemical markers to examine the post‐harvest handling procedures of commercial AMK with excessive sulfur fumigation and maintain consistent quality.

28 citations

Journal ArticleDOI
TL;DR: The dys-regulated fecal β-d-glucosidase activity and deglycosylation metabolism may contribute to the altered pharmacokinetic of ginsenoside Rb1 and its hydrolysis metabolites after ATMs treatment or restraint stress exposure.

26 citations

Journal ArticleDOI
TL;DR: The protocol of virtual screening in identification of novel potential HDAC inhibitors through pharmacophore modeling, 3D-QSAR, molecular docking and molecular dynamics simulation, and results indicated the hit DB03889 with high in silico inhibitory potency was suitable for further experimental analysis.
Abstract: Histone deacetylases (HDACs), a critical family of epigenetic enzymes, has emerged as a promising target for antitumor drugs. Here, we describe our protocol of virtual screening in identification o...

22 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: The design and applications of various kinds of long-lived emissive probes for bioimaging and biosensing via time-resolved photoluminescence techniques are summarized and the imaging contrast and sensing sensitivity are remarkably improved.
Abstract: In this Review article, we systematically summarize the design and applications of various kinds of long-lived emissive probes for bioimaging and biosensing via time-resolved photoluminescence techniques The probes reviewed, including lanthanides, transition-metal complexes, organic dyes, carbon and silicon nanoparticles, metal clusters, and persistent phosphores, exhibit longer luminescence lifetimes than that of autofluorescence from biological tissue and organs When these probes are internalized into living cells or animals, time-gated photoluminescence imaging selectively collects long-lived signals for intensity analysis, while photoluminescence lifetime imaging reports the decay details of each pixel Since the long-lived signals are differentiated from autofluorescence in the time domain, the imaging contrast and sensing sensitivity are remarkably improved The future prospects and challenges in this rapidly growing field are addressed

560 citations

Journal ArticleDOI
TL;DR: This work discusses how QDs are steadily revolutionizing the development of new biosensors along with a myriad of other photonically active nanomaterial-based bioconjugates, and how this field has grown over a relatively short time span.
Abstract: Luminescent semiconductor quantum dots (QDs) are one of the more popular nanomaterials currently utilized within biological applications. However, what is not widely appreciated is their growing role as versatile energy transfer (ET) donors and acceptors within a similar biological context. The progress made on integrating QDs and ET in biological configurations and applications is reviewed in detail here. The goal is to provide the reader with (1) an appreciation for what QDs are capable of in this context, (2) how this field has grown over a relatively short time span, and, in particular, (3) how QDs are steadily revolutionizing the development of new biosensors along with a myriad of other photonically active nanomaterial-based bioconjugates. An initial discussion of QD materials along with key concepts surrounding their preparation and bioconjugation is provided given the defining role these aspects play in the QDs ability to succeed in subsequent ET applications. The discussion is then divided around...

542 citations

Journal ArticleDOI
14 Jun 2017-ACS Nano
TL;DR: This review provides a comprehensive overview of various nanomaterial-enhanced no-wash biosensing technologies and focuses on the analysis of the underlying mechanism of these technologies applied for the early detection of cancer biomarkers ranging from small molecules to proteins, and even whole cancerous cells.
Abstract: In vitro biosensors have been an integral component for early diagnosis of cancer in the clinic. Among them, no-wash biosensors, which only depend on the simple mixing of the signal generating probes and the sample solution without additional washing and separation steps, have been found to be particularly attractive. The outstanding advantages of facile, convenient, and rapid response of no-wash biosensors are especially suitable for point-of-care testing (POCT). One fast-growing field of no-wash biosensor design involves the usage of nanomaterials as signal amplification carriers or direct signal generating elements. The analytical capacity of no-wash biosensors with respect to sensitivity or limit of detection, specificity, stability, and multiplexing detection capacity is largely improved because of their large surface area, excellent optical, electrical, catalytic, and magnetic properties. This review provides a comprehensive overview of various nanomaterial-enhanced no-wash biosensing technologies a...

184 citations