Bio: Jaewon Yang is an academic researcher from Rush University Medical Center. The author has contributed to research in topics: Correction for attenuation & Iterative reconstruction. The author has an hindex of 18, co-authored 80 publications receiving 1744 citations. Previous affiliations of Jaewon Yang include University of California, San Francisco & Rush University.

Papers published on a yearly basis

Papers
More filters
Journal ArticleDOI
TL;DR: For instance, this paper performed a systematic review and meta-analysis of longitudinal studies that assessed initial use of e-cigarettes and subsequent cigarette smoking, and found that e-cigarette use was associated with higher risk for subsequent smoking initiation and past 30-day cigarette smoking.
Abstract: Importance The public health implications of e-cigarettes depend, in part, on whether e-cigarette use affects the risk of cigarette smoking. Objective To perform a systematic review and meta-analysis of longitudinal studies that assessed initial use of e-cigarettes and subsequent cigarette smoking. Data Sources PubMed, EMBASE, Cochrane Library, Web of Science, the 2016 Society for Research on Nicotine and Tobacco 22nd Annual Meeting abstracts, the 2016 Society of Behavioral Medicine 37th Annual Meeting & Scientific Sessions abstracts, and the 2016 National Institutes of Health Tobacco Regulatory Science Program Conference were searched between February 7 and February 17, 2017. The search included indexed terms and text words to capture concepts associated with e-cigarettes and traditional cigarettes in articles published from database inception to the date of the search. Study Selection Longitudinal studies reporting odds ratios for cigarette smoking initiation associated with ever use of e-cigarettes or past 30-day cigarette smoking associated with past 30-day e-cigarette use. Searches yielded 6959 unique studies, of which 9 met inclusion criteria (comprising 17 389 adolescents and young adults). Data Extraction and Synthesis Study quality and risk of bias were assessed using the Newcastle-Ottawa Scale and the Risk of Bias in Non-randomized Studies of Interventions tool, respectively. Data and estimates were pooled using random-effects meta-analysis. Main Outcomes and Measures Among baseline never cigarette smokers, cigarette smoking initiation between baseline and follow-up. Among baseline non–past 30-day cigarette smokers who were past 30-day e-cigarette users, past 30-day cigarette smoking at follow-up. Results Among 17 389 adolescents and young adults, the ages ranged between 14 and 30 years at baseline, and 56.0% were female. The pooled probabilities of cigarette smoking initiation were 23.2% for baseline ever e-cigarette users and 7.2% for baseline never e-cigarette users. The pooled probabilities of past 30-day cigarette smoking at follow-up were 21.5% for baseline past 30-day e-cigarette users and 4.6% for baseline non–past 30-day e-cigarette users. Adjusting for known demographic, psychosocial, and behavioral risk factors for cigarette smoking, the pooled odds ratio for subsequent cigarette smoking initiation was 3.50 (95% CI, 2.38-5.16) for ever vs never e-cigarette users, and the pooled odds ratio for past 30-day cigarette smoking at follow-up was 4.28 (95% CI, 2.52-7.27) for past 30-day e-cigarette vs non–past 30-day e-cigarette users at baseline. A moderate level of heterogeneity was observed among studies ( I2 = 56%). Conclusions and Relevance e-Cigarette use was associated with greater risk for subsequent cigarette smoking initiation and past 30-day cigarette smoking. Strong e-cigarette regulation could potentially curb use among youth and possibly limit the future population-level burden of cigarette smoking.

848 citations

Journal ArticleDOI
TL;DR: ZeDD CT produces natural-looking and quantitatively accurate pseudo-CT images and reduces error in pelvic PET/MRI attenuation correction compared with standard methods.
Abstract: Accurate quantification of uptake on PET images depends on accurate attenuation correction in reconstruction. Current MR-based attenuation correction methods for body PET use a fat and water map derived from a 2-echo Dixon MRI sequence in which bone is neglected. Ultrashort-echo-time or zero-echo-time (ZTE) pulse sequences can capture bone information. We propose the use of patient-specific multiparametric MRI consisting of Dixon MRI and proton-density–weighted ZTE MRI to directly synthesize pseudo-CT images with a deep learning model: we call this method ZTE and Dixon deep pseudo-CT (ZeDD CT). Methods: Twenty-six patients were scanned using an integrated 3-T time-of-flight PET/MRI system. Helical CT images of the patients were acquired separately. A deep convolutional neural network was trained to transform ZTE and Dixon MR images into pseudo-CT images. Ten patients were used for model training, and 16 patients were used for evaluation. Bone and soft-tissue lesions were identified, and the SUVmax was measured. The root-mean-squared error (RMSE) was used to compare the MR-based attenuation correction with the ground-truth CT attenuation correction. Results: In total, 30 bone lesions and 60 soft-tissue lesions were evaluated. The RMSE in PET quantification was reduced by a factor of 4 for bone lesions (10.24% for Dixon PET and 2.68% for ZeDD PET) and by a factor of 1.5 for soft-tissue lesions (6.24% for Dixon PET and 4.07% for ZeDD PET). Conclusion: ZeDD CT produces natural-looking and quantitatively accurate pseudo-CT images and reduces error in pelvic PET/MRI attenuation correction compared with standard methods.

217 citations

Journal ArticleDOI
TL;DR: Quantification results show that the proposed iterative neural network method can outperform the neural network denoising and conventional penalized maximum likelihood methods.
Abstract: PET image reconstruction is challenging due to the ill-poseness of the inverse problem and limited number of detected photons. Recently, the deep neural networks have been widely and successfully used in computer vision tasks and attracted growing interests in medical imaging. In this paper, we trained a deep residual convolutional neural network to improve PET image quality by using the existing inter-patient information. An innovative feature of the proposed method is that we embed the neural network in the iterative reconstruction framework for image representation, rather than using it as a post-processing tool. We formulate the objective function as a constrained optimization problem and solve it using the alternating direction method of multipliers algorithm. Both simulation data and hybrid real data are used to evaluate the proposed method. Quantification results show that our proposed iterative neural network method can outperform the neural network denoising and conventional penalized maximum likelihood methods.

197 citations

Journal ArticleDOI
TL;DR: A method for converting Zero TE MR images into X‐ray attenuation information in the form of pseudo‐CT images is described and its performance for attenuation correction in PET/MR and dose planning in MR‐guided radiation therapy planning (RTP) is demonstrated.
Abstract: Purpose: To describe a method for converting Zero TE (ZTE) MR images into Xray attenuation information in the form of pseudo-CT images and demonstrate its performance for (1) attenuation correction ...

80 citations

Journal ArticleDOI
TL;DR: Deep neural network methods to derive the continuous attenuation coefficients for brain PET imaging from MR images are presented and a modified U-net structure is proposed, named GroupU-net, to efficiently make use of both Dixon and ZTE information through group convolution modules when the network goes deeper.
Abstract: Positron emission tomography (PET) is a functional imaging modality widely used in neuroscience studies. To obtain meaningful quantitative results from PET images, attenuation correction is necessary during image reconstruction. For PET/MR hybrid systems, PET attenuation is challenging as magnetic resonance (MR) images do not reflect attenuation coefficients directly. To address this issue, we present deep neural network methods to derive the continuous attenuation coefficients for brain PET imaging from MR images. With only Dixon MR images as the network input, the existing U-net structure was adopted and analysis using forty patient data sets shows it is superior to other Dixon-based methods. When both Dixon and zero echo time (ZTE) images are available, we have proposed a modified U-net structure, named GroupU-net, to efficiently make use of both Dixon and ZTE information through group convolution modules when the network goes deeper. Quantitative analysis based on fourteen real patient data sets demonstrates that both network approaches can perform better than the standard methods, and the proposed network structure can further reduce the PET quantification error compared to the U-net structure.

78 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: The recent advance of deep learning based sensor-based activity recognition is surveyed from three aspects: sensor modality, deep model, and application and detailed insights on existing work are presented and grand challenges for future research are proposed.

1,334 citations

Journal ArticleDOI
TL;DR: Disease prevention is focused on smoking avoidance and cessation, and future work should focus on smoking cessation campaigns and better understanding disease development and treatment strategies in nonsmokers.

787 citations

Journal ArticleDOI
TL;DR: The general principles of DL and convolutional neural networks are introduced, five major areas of application of DL in medical imaging and radiation therapy are surveyed, common themes are identified, methods for dataset expansion are discussed, and lessons learned, remaining challenges, and future directions are summarized.
Abstract: The goals of this review paper on deep learning (DL) in medical imaging and radiation therapy are to (a) summarize what has been achieved to date; (b) identify common and unique challenges, and strategies that researchers have taken to address these challenges; and (c) identify some of the promising avenues for the future both in terms of applications as well as technical innovations. We introduce the general principles of DL and convolutional neural networks, survey five major areas of application of DL in medical imaging and radiation therapy, identify common themes, discuss methods for dataset expansion, and conclude by summarizing lessons learned, remaining challenges, and future directions.

525 citations