scispace - formally typeset
Search or ask a question
Author

Jakob Assländer

Bio: Jakob Assländer is an academic researcher from New York University. The author has contributed to research in topics: Bloch equations & Spin echo. The author has an hindex of 14, co-authored 29 publications receiving 687 citations. Previous affiliations of Jakob Assländer include Technische Universität München & University of Freiburg.

Papers
More filters
Journal ArticleDOI
TL;DR: In this paper, a low-rank inverse problem was proposed to reduce the computational burden by reducing the number of Fourier transformations and the low rank approximation improved the conditioning of the problem, which was further improved by extending the low-ranking inverse problem to an augmented Lagrangian that is solved by the alternating direction method of multipliers (ADMM).
Abstract: Purpose The proposed reconstruction framework addresses the reconstruction accuracy, noise propagation and computation time for Magnetic Resonance Fingerprinting (MRF). Methods Based on a singular value decomposition (SVD) of the signal evolution, MRF is formulated as a low rank inverse problem in which one image is reconstructed for each singular value under consideration. This low rank approximation of the signal evolution reduces the computational burden by reducing the number of Fourier transformations. Also, the low rank approximation improves the conditioning of the problem, which is further improved by extending the low rank inverse problem to an augmented Lagrangian that is solved by the alternating direction method of multipliers (ADMM). The root mean square error and the noise propagation are analyzed in simulations. For verification, in vivo examples are provided. Results The proposed low rank ADMM approach shows a reduced root mean square error compared to the original fingerprinting reconstruction, to a low rank approximation alone and to an ADMM approach without a low rank approximation. Incorporating sensitivity encoding allows for further artifact reduction. Conclusion The proposed reconstruction provides robust convergence, reduced computational burden and improved image quality compared to other MRF reconstruction approaches evaluated in this study.

124 citations

Journal ArticleDOI
TL;DR: In this paper, a low-rank inverse problem was formulated for magnetic resonance fingerprinting and an alternating direction method of multipliers approach was proposed to reduce the number of Fourier transformations.
Abstract: The proposed reconstruction framework addresses the reconstruction accuracy, noise propagation and computation time for magnetic resonance fingerprinting. Based on a singular value decomposition of the signal evolution, magnetic resonance fingerprinting is formulated as a low rank (LR) inverse problem in which one image is reconstructed for each singular value under consideration. This LR approximation of the signal evolution reduces the computational burden by reducing the number of Fourier transformations. Also, the LR approximation improves the conditioning of the problem, which is further improved by extending the LR inverse problem to an augmented Lagrangian that is solved by the alternating direction method of multipliers. The root mean square error and the noise propagation are analyzed in simulations. For verification, in vivo examples are provided. The proposed LR alternating direction method of multipliers approach shows a reduced root mean square error compared to the original fingerprinting reconstruction, to a LR approximation alone and to an alternating direction method of multipliers approach without a LR approximation. Incorporating sensitivity encoding allows for further artifact reduction. The proposed reconstruction provides robust convergence, reduced computational burden and improved image quality compared to other magnetic resonance fingerprinting reconstruction approaches evaluated in this study. Magn Reson Med 79:83-96, 2018. © 2017 International Society for Magnetic Resonance in Medicine.

112 citations

Journal ArticleDOI
TL;DR: It is shown how a pseudo steady state can be achieved, which restores the spin echo nature of steady‐state free precession.
Abstract: Purpose This article discusses the signal behavior in the case the flip angle in steady-state free precession sequences is continuously varied as suggested for MR-fingerprinting sequences Flip angle variations prevent the establishment of a steady state and introduce instabilities regarding to magnetic field inhomogeneities and intravoxel dephasing We show how a pseudo steady state can be achieved, which restores the spin echo nature of steady-state free precession Methods Based on geometrical considerations, relationships between the flip angle, repetition and echo time are derived that suffice to the establishment of a pseudo steady state The theory is tested with Bloch simulations as well as phantom and in vivo experiments Results A typical steady-state free precession passband can be restored with the proposed conditions The stability of the pseudo steady state is demonstrated by comparing the evolution of the signal of a single isochromat to one resulting from a spin ensemble As confirmed by experiments, magnetization in a pseudo steady state can be described with fewer degrees of freedom compared to the original fingerprinting and the pseudo steady state results in more reliable parameter maps Conclusion The proposed conditions restore the spin-echo-like signal behavior typical for steady-state free precession in fingerprinting sequences, making this approach more robust to B0 variations Magn Reson Med 77:1151-1161, 2017 © 2016 International Society for Magnetic Resonance in Medicine

85 citations

Journal ArticleDOI
TL;DR: It is shown that the loss of spatial information is reduced when using a stack of spirals trajectory compared to concentric shells, making a meaningful image reconstruction impossible in the affected areas.

79 citations

Journal ArticleDOI
TL;DR: A novel imaging method for fast three‐dimensional‐MR‐encephalography whole brain coverage based on undersampled, single‐shot concentric shells trajectories and the use of multiple small receiver coils is described.
Abstract: MR-encephalography is a technique that allows real-time observation of functional changes in the brain with a time-resolution of 100 ms. The high sampling rate is enabled by the use of undersampled image acquisition with regularized reconstruction. The article describes a novel imaging method for fast three-dimensional-MR-encephalography whole brain coverage based on undersampled, single-shot concentric shells trajectories and the use of multiple small receiver coils. The technique allows the observation of changes in blood oxygenation level dependent signal as a measure of brain physiology at very high temporal resolution.

73 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: It is described that 4D Flow CMR can be clinically advantageous because placement of a single acquisition volume is straightforward and enables flow through any plane across it to be calculated retrospectively and with good accuracy.
Abstract: Pulsatile blood flow through the cavities of the heart and great vessels is time-varying and multidirectional. Access to all regions, phases and directions of cardiovascular flows has formerly been limited. Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) has enabled more comprehensive access to such flows, with typical spatial resolution of 1.5×1.5×1.5 – 3×3×3 mm3, typical temporal resolution of 30–40 ms, and acquisition times in the order of 5 to 25 min. This consensus paper is the work of physicists, physicians and biomedical engineers, active in the development and implementation of 4D Flow CMR, who have repeatedly met to share experience and ideas. The paper aims to assist understanding of acquisition and analysis methods, and their potential clinical applications with a focus on the heart and greater vessels. We describe that 4D Flow CMR can be clinically advantageous because placement of a single acquisition volume is straightforward and enables flow through any plane across it to be calculated retrospectively and with good accuracy. We also specify research and development goals that have yet to be satisfactorily achieved. Derived flow parameters, generally needing further development or validation for clinical use, include measurements of wall shear stress, pressure difference, turbulent kinetic energy, and intracardiac flow components. The dependence of measurement accuracy on acquisition parameters is considered, as are the uses of different visualization strategies for appropriate representation of time-varying multidirectional flow fields. Finally, we offer suggestions for more consistent, user-friendly implementation of 4D Flow CMR acquisition and data handling with a view to multicenter studies and more widespread adoption of the approach in routine clinical investigations.

638 citations

Journal ArticleDOI
TL;DR: This parallel imaging technique began over a decade ago and through recent sequence improvements has reduced the acquisition time of multi-slice EPI by over ten fold.

423 citations

Journal ArticleDOI
TL;DR: Through its platform-independent Matlab implementation, open-source distribution, and modular structure, the PhysIO Toolbox renders physiological noise correction an accessible preprocessing step for fMRI data.

252 citations

Journal ArticleDOI
TL;DR: The findings using critically sampled magnetic resonance encephalography open a new view into cerebral fluid dynamics, since glymphatic system failure may precede protein accumulations in diseases such as Alzheimer's dementia, and offers a novel approach to image brain fluid dynamics.
Abstract: The theory on the glymphatic convection mechanism of cerebrospinal fluid holds that cardiac pulsations in part pump cerebrospinal fluid from the peri-arterial spaces through the extracellular tissue into the peri-venous spaces facilitated by aquaporin water channels. Since cardiac pulses cannot be the sole mechanism of glymphatic propulsion, we searched for additional cerebrospinal fluid pulsations in the human brain with ultra-fast magnetic resonance encephalography. We detected three types of physiological mechanisms affecting cerebral cerebrospinal fluid pulsations: cardiac, respiratory, and very low frequency pulsations. The cardiac pulsations induce a negative magnetic resonance encephalography signal change in peri-arterial regions that extends centrifugally and covers the brain in ≈1 Hz cycles. The respiratory ≈0.3 Hz pulsations are centripetal periodical pulses that occur dominantly in peri-venous areas. The third type of pulsation was very low frequency (VLF 0.001-0.023 Hz) and low frequency (LF 0.023-0.73 Hz) waves that both propagate with unique spatiotemporal patterns. Our findings using critically sampled magnetic resonance encephalography open a new view into cerebral fluid dynamics. Since glymphatic system failure may precede protein accumulations in diseases such as Alzheimer's dementia, this methodological advance offers a novel approach to image brain fluid dynamics that potentially can enable early detection and intervention in neurodegenerative diseases.

245 citations

Journal ArticleDOI
TL;DR: Preliminary results have found corresponding networks at frequencies above 0.1 Hz showed better stability in both spatial and temporal dimensions from the sliding-window analysis of the time series, which suggests the potential of using high temporal resolution MREG sequences to track dynamic resting-state networks at sub-minute time scale.

141 citations