scispace - formally typeset
Search or ask a question
Author

James K. Kearns

Bio: James K. Kearns is an academic researcher from Southern Connecticut State University. The author has contributed to research in topics: Silver nitrate. The author has an hindex of 1, co-authored 2 publications receiving 4 citations.

Papers
More filters
Journal ArticleDOI
TL;DR: In this paper, the authors examined the blue color value produced when arsine reacts with silver nitrate impregnated test strips and found that the color intensity of the strips observed to be inversely proportional to the concentration of As (III).
Abstract: This study confronts the questionable reliability and accuracy of field test kits distributed globally to determine arsenic in drinking water. Because kits are the primary method of arsenic analysis in the areas most affected, an alternate, nontoxic formulation is needed to provide accurate results. Hypothesizing that introducing silver nitrate as the reagent in test kits could successfully substitute for restricted mercuric bromide, the study found that the reformulated kits provided reliable, precise, and accurate results over a broader range of contamination. Digital image analysis was used to examine the blue color value produced when arsine reacts with silver nitrate impregnated test strips. An optimal concentration of AgNO3 exhibiting the greatest linearity was determined by graphical comparison and the color intensity of the strips observed to be inversely proportional to the concentration of As (III). Adapted field test kits were then constructed to examine water samples ranging in arsenic contamination from 0 to 50 μg L−1. A series of reactions was completed to demonstrate reproducibility and test for the accuracy of the procedure. Statistical examination of colorimetrically quantified results confirmed the hypothesis that silver nitrate can reliably and precisely expand the kit’s range of detection while maintaining its low cost, quick assessment, and uncomplicated technique. This new method, using 0.4% m/v AgNO3 as a reagent for the Gutzeit reaction, was able to distinguish between concentrations of 0, 5, 10, 15, and 50 μg L−1 at the 95% confidence level.

6 citations

Journal ArticleDOI
TL;DR: In this paper, the graphite furnace atomic absorption spectrometer has been used for food and a pervasive contaminant, and students whose math skills are in development can complete it successfully because algebraic calculations are used at each stage of the materials examination.
Abstract: By focusing on food and a pervasive contaminant, this experiment engages student interest and effort while providing essential instruction and experience. As institutions are challenged by existing and emerging budgetary constraints, this experiment offers a determination approach employing commonly available instrumentation, the graphite furnace atomic absorption spectrometer. The module provides a broad range of experiences: it introduces the lyophilizer, offers practice in a multistep novel digestion method, presents the theoretical foundation and practical application of atomic absorption spectroscopy, and provides an opportunity to record, calculate, and report findings. Students whose math skills are in development can complete it successfully because algebraic calculations are used at each stage of the materials’ examination. Finally, when their reports align with extensive international research, the lab offers students assurance of their growing scientific competence.

Cited by
More filters
Journal ArticleDOI
TL;DR: St stakeholders carefully re-consider the use of poorly performing field test kits until better quality control of components of these kits is implemented, and it is recommended that field test kit manufacturers provide suitable internal standards in every kit box for users to verify the veracity of manufacturer provided color charts.

31 citations

Journal ArticleDOI
TL;DR: In this article, a flow batch assembly coupled with a drop system was used to determine arsenic in water samples without chemical/external pretreatment was employed, and the results showed that the proposed low-cost method exhibits good performance, satisfactory detection limit (0.07 µg L−1) and linear response from 0.05 to 1.00 µg l−1 of As.

10 citations

Journal ArticleDOI
TL;DR: This test is based on As(III) chelation with pyrrolidine dithiocarbamate followed by spectrometric measurement of absorbance, and was validated by comparison with AAS quantification of As after As( III)/As(V) separation.

2 citations