Janusz Jezewski

Bio: Janusz Jezewski is an academic researcher from Instituto Tecnológico Autónomo de México. The author has contributed to research in topics: Fetal Heart Rate Variability & Fuzzy logic. The author has an hindex of 24, co-authored 134 publications receiving 1609 citations.


Papers
More filters
Journal ArticleDOI
TL;DR: Investigations confirmed that abdominal electrocardiography, even in its current stage of development, offers an accuracy equal to or higher than an ultrasound method, at the same time providing some additional features.
Abstract: The main aim of our work was to assess the reliability of indirect abdominal electrocardiography as an alternative to the commonly used Doppler ultrasound monitoring technique. As a reference method, we used direct fetal electrocardiography. Direct and abdominal signals were acquired simultaneously, using dedicated instrumentation. The developed method of maternal signal suppression as well as fetal QRS complexes detection was presented. Recordings were collected during established labors, each consisted of four signals from the maternal abdomen and the reference signal acquired directly from the fetal head. After assessing the performance of the QRS detector, the accuracy of fetal heart rate measurement was evaluated. Additionally, to reduce the influence of inaccurately detected R-waves, some validation rules were proposed. The obtained results revealed that the indirect method is able to provide an accuracy sufficient for a reliable assessment of fetal heart rate variability. However, the method is very sensitive to recording conditions, influencing the quality of signals. Our investigations confirmed that abdominal electrocardiography, even in its current stage of development, offers an accuracy equal to or higher than an ultrasound method, at the same time providing some additional features.

147 citations

Journal ArticleDOI
TL;DR: The obtained results show that both methods demonstrate high agreement in relation to the number of contractions recognized as being consistent, and the appropriate way of further development of electrohysterography seems to be spectral analysis.
Abstract: Monitoring of uterine contraction activity is an important diagnostic tool used during both pregnancy and labour. The strain the pregnant uterus exerts on the maternal abdomen is measured via external tocography. However, limitation of this approach has caused the development of another technique-electrohysterography--which is based on the recording of electrical uterine activity. A computer-aided system is presented, which allows the recording of electrohysterographic signals from the maternal abdomen and their on-line analysis both in time and frequency domains. As a research material, we acquired 108 traces during a 24 h period before labour from a group of patients between 37 and 40 weeks of gestation. The comparison study between electrohysterography and tocography was carried out thanks to the possibility of simultaneous recording of mechanical and electrical uterine activities. The obtained results show that both methods demonstrate high agreement in relation to the number of contractions recognized as being consistent. However, their agreement in relation to the quantitative description of recognized patterns has appeared to be unacceptable to consider these methods as fully alternative. The appropriate way of further development of electrohysterography seems to be spectral analysis. Several spectral parameters describing electrophysiological properties of uterine muscle can be obtained by the use of electrohysterographic signals.

99 citations

Journal ArticleDOI
TL;DR: Evaluation of the commonly used Doppler ultrasound technique for monitoring of mechanical activity of fetal heart proved that evaluation of the acquisition technique influence on fetal well-being assessment cannot be accomplished basing on direct measurements of heartbeats only.
Abstract: A method for comparison of two acquisition techniques that are applied in clinical practice to provide information on fetal condition is presented. The aim of this work was to evaluate the commonly used Doppler ultrasound technique for monitoring of mechanical activity of fetal heart. Accuracy of beat-to-beat interval determination together with its influence on indices describing the fetal heart rate (FHR) variability calculated automatically using computer-aided fetal monitoring system were examined. We considered the direct fetal electrocardiography as a reference technique because it ensures the highest possible accuracy of heart interval measurement, and additionally all the definitions of popular time domain parameters quantifying FHR variability formerly have been created using the fetal electrocardiogram. We evaluated the reliability of various so called short-term and long-term variability indices, when they are calculated automatically using the signal obtained via the Doppler US from a fetal monitor. The results proved that evaluation of the acquisition technique influence on fetal well-being assessment cannot be accomplished basing on direct measurements of heartbeats only. The more relevant is the estimation of accuracy of the variability indices, since analysis of their changes can significantly increase predictability of fetal distress

93 citations

Journal ArticleDOI
19 May 2017-Sensors
TL;DR: The approach could offer the potential to be used in clinical practice to establish recommendations for standard electrode placement and find the optimal adaptive filter settings for extracting high quality fetal ECG signals for further processing, and ensure the reliable detection of fetal hypoxia.
Abstract: This paper is focused on the design, implementation and verification of a novel method for the optimization of the control parameters (such as step size μ and filter order N) of LMS and RLS adaptive filters used for noninvasive fetal monitoring. The optimization algorithm is driven by considering the ECG electrode positions on the maternal body surface in improving the performance of these adaptive filters. The main criterion for optimal parameter selection was the Signal-to-Noise Ratio (SNR). We conducted experiments using signals supplied by the latest version of our LabVIEW-Based Multi-Channel Non-Invasive Abdominal Maternal-Fetal Electrocardiogram Signal Generator, which provides the flexibility and capability of modeling the principal distribution of maternal/fetal ECGs in the human body. Our novel algorithm enabled us to find the optimal settings of the adaptive filters based on maternal surface ECG electrode placements. The experimental results further confirmed the theoretical assumption that the optimal settings of these adaptive filters are dependent on the ECG electrode positions on the maternal body, and therefore, we were able to achieve far better results than without the use of optimization. These improvements in turn could lead to a more accurate detection of fetal hypoxia. Consequently, our approach could offer the potential to be used in clinical practice to establish recommendations for standard electrode placement and find the optimal adaptive filter settings for extracting high quality fetal ECG signals for further processing. Ultimately, diagnostic-grade fetal ECG signals would ensure the reliable detection of fetal hypoxia.

92 citations

Journal ArticleDOI
TL;DR: The results demonstrated that even though these advanced signal processing methods are suitable for the non-invasive estimation and monitoring of the fHR information from maternal aECG signals, their utility for further morphological analysis of the extracted fECGs signals remains questionable and warrants further work.
Abstract: Non-adaptive signal processing methods have been successfully applied to extract fetal electrocardiograms (fECGs) from maternal abdominal electrocardiograms (aECGs); and initial tests to evaluate the efficacy of these methods have been carried out by using synthetic data. Nevertheless, performance evaluation of such methods using real data is a much more challenging task and has neither been fully undertaken nor reported in the literature. Therefore, in this investigation, we aimed to compare the effectiveness of two popular non-adaptive methods (the ICA and PCA) to explore the non-invasive (NI) extraction (separation) of fECGs, also known as NI-fECGs from aECGs. The performance of these well-known methods was enhanced by an adaptive algorithm, compensating amplitude difference and time shift between the estimated components. We used real signals compiled in 12 recordings (real01-real12). Five of the recordings were from the publicly available database (PhysioNet-Abdominal and Direct Fetal Electrocardiogram Database), which included data recorded by multiple abdominal electrodes. Seven more recordings were acquired by measurements performed at the Institute of Medical Technology and Equipment, Zabrze, Poland. Therefore, in total we used 60 min of data (i.e., around 88,000 R waves) for our experiments. This dataset covers different gestational ages, fetal positions, fetal positions, maternal body mass indices (BMI), etc. Such a unique heterogeneous dataset of sufficient length combining continuous Fetal Scalp Electrode (FSE) acquired and abdominal ECG recordings allows for robust testing of the applied ICA and PCA methods. The performance of these signal separation methods was then comprehensively evaluated by comparing the fetal Heart Rate (fHR) values determined from the extracted fECGs with those calculated from the fECG signals recorded directly by means of a reference FSE. Additionally, we tested the possibility of non-invasive ST analysis (NI-STAN) by determining the T/QRS ratio. Our results demonstrated that even though these advanced signal processing methods are suitable for the non-invasive estimation and monitoring of the fHR information from maternal aECG signals, their utility for further morphological analysis of the extracted fECG signals remains questionable and warrants further work.

79 citations


Cited by
More filters
Book ChapterDOI
E.R. Davies1
01 Jan 1990
TL;DR: This chapter introduces the subject of statistical pattern recognition (SPR) by considering how features are defined and emphasizes that the nearest neighbor algorithm achieves error rates comparable with those of an ideal Bayes’ classifier.
Abstract: This chapter introduces the subject of statistical pattern recognition (SPR). It starts by considering how features are defined and emphasizes that the nearest neighbor algorithm achieves error rates comparable with those of an ideal Bayes’ classifier. The concepts of an optimal number of features, representativeness of the training data, and the need to avoid overfitting to the training data are stressed. The chapter shows that methods such as the support vector machine and artificial neural networks are subject to these same training limitations, although each has its advantages. For neural networks, the multilayer perceptron architecture and back-propagation algorithm are described. The chapter distinguishes between supervised and unsupervised learning, demonstrating the advantages of the latter and showing how methods such as clustering and principal components analysis fit into the SPR framework. The chapter also defines the receiver operating characteristic, which allows an optimum balance between false positives and false negatives to be achieved.

1,189 citations

Journal ArticleDOI
Maoguo Gong1, Yan Liang1, Jiao Shi1, Wenping Ma1, Jingjing Ma1 
TL;DR: An improved fuzzy C-means (FCM) algorithm for image segmentation is presented by introducing a tradeoff weighted fuzzy factor and a kernel metric and results show that the new algorithm is effective and efficient, and is relatively independent of this type of noise.
Abstract: In this paper, we present an improved fuzzy C-means (FCM) algorithm for image segmentation by introducing a tradeoff weighted fuzzy factor and a kernel metric. The tradeoff weighted fuzzy factor depends on the space distance of all neighboring pixels and their gray-level difference simultaneously. By using this factor, the new algorithm can accurately estimate the damping extent of neighboring pixels. In order to further enhance its robustness to noise and outliers, we introduce a kernel distance measure to its objective function. The new algorithm adaptively determines the kernel parameter by using a fast bandwidth selection rule based on the distance variance of all data points in the collection. Furthermore, the tradeoff weighted fuzzy factor and the kernel distance measure are both parameter free. Experimental results on synthetic and real images show that the new algorithm is effective and efficient, and is relatively independent of this type of noise.

546 citations

Journal ArticleDOI
TL;DR: The Guidelines for Reporting Articles on Psychiatry and Heart rate variability (GRAPH), a checklist with four domains: participant selection, interbeat interval collection, data preparation and HRV calculation, is proposed.
Abstract: The number of publications investigating heart rate variability (HRV) in psychiatry and the behavioral sciences has increased markedly in the last decade. In addition to the significant debates surrounding ideal methods to collect and interpret measures of HRV, standardized reporting of methodology in this field is lacking. Commonly cited recommendations were designed well before recent calls to improve research communication and reproducibility across disciplines. In an effort to standardize reporting, we propose the Guidelines for Reporting Articles on Psychiatry and Heart rate variability (GRAPH), a checklist with four domains: participant selection, interbeat interval collection, data preparation and HRV calculation. This paper provides an overview of these four domains and why their standardized reporting is necessary to suitably evaluate HRV research in psychiatry and related disciplines. Adherence to these communication guidelines will help expedite the translation of HRV research into a potential psychiatric biomarker by improving interpretation, reproducibility and future meta-analyses.

268 citations

Journal ArticleDOI
TL;DR: The practical application of the democratization of medical devices for both patients and health-care providers is described and unexplored research directions and potential trends to solve uncharted research problems are identified.
Abstract: The Internet of Medical Things (IoMT) designates the interconnection of communication-enabled medical-grade devices and their integration to wider-scale health networks in order to improve patients’ health. However, because of the critical nature of health-related systems, the IoMT still faces numerous challenges, more particularly in terms of reliability, safety, and security. In this paper, we present a comprehensive literature review of recent contributions focused on improving the IoMT through the use of formal methodologies provided by the cyber-physical systems community. We describe the practical application of the democratization of medical devices for both patients and health-care providers. We also identify unexplored research directions and potential trends to solve uncharted research problems.

253 citations

Journal ArticleDOI
TL;DR: The main idea in this paper is to describe key papers and provide some guidelines to help medical practitioners to explore previous works and identify interesting areas for future research.
Abstract: Data mining is a powerful method to extract knowledge from data. Raw data faces various challenges that make traditional method improper for knowledge extraction. Data mining is supposed to be able to handle various data types in all formats. Relevance of this paper is emphasized by the fact that data mining is an object of research in different areas. In this paper, we review previous works in the context of knowledge extraction from medical data. The main idea in this paper is to describe key papers and provide some guidelines to help medical practitioners. Medical data mining is a multidisciplinary field with contribution of medicine and data mining. Due to this fact, previous works should be classified to cover all users' requirements from various fields. Because of this, we have studied papers with the aim of extracting knowledge from structural medical data published between 1999 and 2013. We clarify medical data mining and its main goals. Therefore, each paper is studied based on the six medical tasks: screening, diagnosis, treatment, prognosis, monitoring and management. In each task, five data mining approaches are considered: classification, regression, clustering, association and hybrid. At the end of each task, a brief summarization and discussion are stated. A standard framework according to CRISP-DM is additionally adapted to manage all activities. As a discussion, current issue and future trend are mentioned. The amount of the works published in this scope is substantial and it is impossible to discuss all of them on a single work. We hope this paper will make it possible to explore previous works and identify interesting areas for future research.

220 citations