scispace - formally typeset
Search or ask a question

Showing papers by "Jin Hyung Lee published in 2018"


Journal ArticleDOI
TL;DR: To develop a super‐resolution technique using convolutional neural networks for generating thin‐slice knee MR images from thicker input slices, and compare this method with alternative through‐plane interpolation methods.
Abstract: PURPOSE To develop a super-resolution technique using convolutional neural networks for generating thin-slice knee MR images from thicker input slices, and compare this method with alternative through-plane interpolation methods. METHODS We implemented a 3D convolutional neural network entitled DeepResolve to learn residual-based transformations between high-resolution thin-slice images and lower-resolution thick-slice images at the same center locations. DeepResolve was trained using 124 double echo in steady-state (DESS) data sets with 0.7-mm slice thickness and tested on 17 patients. Ground-truth images were compared with DeepResolve, clinically used tricubic interpolation, and Fourier interpolation methods, along with state-of-the-art single-image sparse-coding super-resolution. Comparisons were performed using structural similarity, peak SNR, and RMS error image quality metrics for a multitude of thin-slice downsampling factors. Two musculoskeletal radiologists ranked the 3 data sets and reviewed the diagnostic quality of the DeepResolve, tricubic interpolation, and ground-truth images for sharpness, contrast, artifacts, SNR, and overall diagnostic quality. Mann-Whitney U tests evaluated differences among the quantitative image metrics, reader scores, and rankings. Cohen's Kappa (κ) evaluated interreader reliability. RESULTS DeepResolve had significantly better structural similarity, peak SNR, and RMS error than tricubic interpolation, Fourier interpolation, and sparse-coding super-resolution for all downsampling factors (p < .05, except 4 × and 8 × sparse-coding super-resolution downsampling factors). In the reader study, DeepResolve significantly outperformed (p < .01) tricubic interpolation in all image quality categories and overall image ranking. Both readers had substantial scoring agreement (κ = 0.73). CONCLUSION DeepResolve was capable of resolving high-resolution thin-slice knee MRI from lower-resolution thicker slices, achieving superior quantitative and qualitative diagnostic performance to both conventionally used and state-of-the-art methods.

243 citations


Journal ArticleDOI
TL;DR: Information is provided on the utility of fMRI, and approaches to consider when using f MRI, for studies of Alzheimer's disease in animal models, and addresses important considerations concerning model choice, anesthetic use and application of stimuli.
Abstract: Alzheimer's disease is a leading healthcare challenge facing our society today. Functional magnetic resonance imaging (fMRI) of the brain has played an important role in our efforts to understand how Alzheimer's disease alters brain function. Using fMRI in animal models of Alzheimer's disease has the potential to provide us with a more comprehensive understanding of the observations made in human clinical fMRI studies. However, using fMRI in animal models of Alzheimer's disease presents some unique challenges. Here, we highlight some of these challenges and discuss potential solutions for researchers interested in performing fMRI in animal models. First, we briefly summarize our current understanding of Alzheimer's disease from a mechanistic standpoint. We then overview the wide array of animal models available for studying this disease and how to choose the most appropriate model to study, depending on which aspects of the condition researchers seek to investigate. Finally, we discuss the contributions of fMRI to our understanding of Alzheimer's disease and the issues to consider when designing fMRI studies for animal models, such as differences in brain activity based on anesthetic choice and ways to interrogate more specific questions in rodents beyond those that can be addressed in humans. The goal of this article is to provide information on the utility of fMRI, and approaches to consider when using fMRI, for studies of Alzheimer's disease in animal models.

19 citations


Book ChapterDOI
16 Sep 2018
TL;DR: It is demonstrated how super-resolution (SR) can be utilized to maintain adequate SNR for accurate quantification of the T\(_2\) relaxation time biomarker, while simultaneously generating high-resolution images.
Abstract: Obtaining magnetic resonance images (MRI) with high resolution and generating quantitative image-based biomarkers for assessing tissue biochemistry is crucial in clinical and research applications. However, acquiring quantitative biomarkers requires high signal-to-noise ratio (SNR), which is at odds with high-resolution in MRI, especially in a single rapid sequence. In this paper, we demonstrate how super-resolution (SR) can be utilized to maintain adequate SNR for accurate quantification of the T\(_2\) relaxation time biomarker, while simultaneously generating high-resolution images. We compare the efficacy of resolution enhancement using metrics such as peak SNR and structural similarity. We assess accuracy of cartilage T\(_2\) relaxation times by comparing against a standard reference method. Our evaluation suggests that SR can successfully maintain high-resolution and generate accurate biomarkers for accelerating MRI scans and enhancing the value of clinical and research MRI.

18 citations


Journal ArticleDOI
TL;DR: The ofMRI technology will be introduced with advanced approaches to bring it to its full potential, ending with examples of dissecting neurological disease circuits utilizing ofMRI.

1 citations


Posted Content
TL;DR: In this paper, the authors demonstrate how super-resolution can be utilized to maintain adequate SNR for accurate quantification of the T2 relaxation time biomarker, while simultaneously generating high-resolution images.
Abstract: Obtaining magnetic resonance images (MRI) with high resolution and generating quantitative image-based biomarkers for assessing tissue biochemistry is crucial in clinical and research applications. How- ever, acquiring quantitative biomarkers requires high signal-to-noise ratio (SNR), which is at odds with high-resolution in MRI, especially in a single rapid sequence. In this paper, we demonstrate how super-resolution can be utilized to maintain adequate SNR for accurate quantification of the T2 relaxation time biomarker, while simultaneously generating high- resolution images. We compare the efficacy of resolution enhancement using metrics such as peak SNR and structural similarity. We assess accuracy of cartilage T2 relaxation times by comparing against a standard reference method. Our evaluation suggests that SR can successfully maintain high-resolution and generate accurate biomarkers for accelerating MRI scans and enhancing the value of clinical and research MRI.

Patent
21 Jun 2018
TL;DR: In this paper, a timer synchronized to a stimulation system is used for pre-triggering imaging scans (e.g. fMRI scans) using an electronic timer synchronized with the stimulation system.
Abstract: Examples described herein may provide for pre-triggering imaging scans (e.g. fMRI scans) using an electronic timer synchronized to a stimulation system.