Author
Joachim Schulz
Other affiliations: University of Oulu, University of Hamburg, Karlsruhe Institute of Technology ...read more
Bio: Joachim Schulz is an academic researcher from European XFEL. The author has contributed to research in topics: Laser & LIGA. The author has an hindex of 41, co-authored 158 publications receiving 8048 citations. Previous affiliations of Joachim Schulz include University of Oulu & University of Hamburg.
Topics: Laser, LIGA, Free-electron laser, Photoionization, Femtosecond
Papers published on a yearly basis
Papers
More filters
••
University of Hamburg1, Arizona State University2, Uppsala University3, Max Planck Society4, European XFEL5, SLAC National Accelerator Laboratory6, Forschungszentrum Jülich7, Lawrence Livermore National Laboratory8, Lawrence Berkeley National Laboratory9, University of Gothenburg10, Technical University of Berlin11, Swedish University of Agricultural Sciences12
TL;DR: This work offers a new approach to structure determination of macromolecules that do not yield crystals of sufficient size for studies using conventional radiation sources or are particularly sensitive to radiation damage, by using pulses briefer than the timescale of most damage processes.
Abstract: X-ray crystallography provides the vast majority of macromolecular structures, but the success of the method relies on growing crystals of sufficient size. In conventional measurements, the necessary increase in X-ray dose to record data from crystals that are too small leads to extensive damage before a diffraction signal can be recorded(1-3). It is particularly challenging to obtain large, well-diffracting crystals of membrane proteins, for which fewer than 300 unique structures have been determined despite their importance in all living cells. Here we present a method for structure determination where single-crystal X-ray diffraction 'snapshots' are collected from a fully hydrated stream of nanocrystals using femtosecond pulses from a hard-X-ray free-electron laser, the Linac Coherent Light Source(4). We prove this concept with nanocrystals of photosystem I, one of the largest membrane protein complexes(5). More than 3,000,000 diffraction patterns were collected in this study, and a three-dimensional data set was assembled from individual photosystem I nanocrystals (similar to 200 nm to 2 mm in size). We mitigate the problem of radiation damage in crystallography by using pulses briefer than the timescale of most damage processes(6). This offers a new approach to structure determination of macromolecules that do not yield crystals of sufficient size for studies using conventional radiation sources or are particularly sensitive to radiation damage.
1,708 citations
••
Uppsala University1, University of Hamburg2, Aix-Marseille University3, Stanford University4, Swedish University of Agricultural Sciences5, Arizona State University6, Lawrence Berkeley National Laboratory7, Lawrence Livermore National Laboratory8, Max Planck Society9, Technical University of Berlin10
TL;DR: This work shows that high-quality diffraction data can be obtained with a single X-ray pulse from a non-crystalline biological sample, a single mimivirus particle, which was injected into the pulsed beam of a hard-X-ray free-electron laser, the Linac Coherent Light Source.
Abstract: The start-up of the Linac Coherent Light Source (LCLS), the new femtosecond hard X-ray laser facility in Stanford, California, has brought high expectations of a new era for biological imaging. The intense, ultrashort X-ray pulses allow diffraction imaging of small structures before radiation damage occurs. Two papers in this issue of Nature present proof-of-concept experiments showing the LCLS in action. Chapman et al. tackle structure determination from nanocrystals of macromolecules that cannot be grown in large crystals. They obtain more than three million diffraction patterns from a stream of nanocrystals of the membrane protein photosystem I, and assemble a three-dimensional data set for this protein. Seibert et al. obtain images of a non-crystalline biological sample, mimivirus, by injecting a beam of cooled mimivirus particles into the X-ray beam. The start-up of the new femtosecond hard X-ray laser facility in Stanford, the Linac Coherent Light Source, has brought high expectations for a new era for biological imaging. The intense, ultrashort X-ray pulses allow diffraction imaging of small structures before radiation damage occurs. This new capability is tested for the problem of imaging a non-crystalline biological sample. Images of mimivirus are obtained, the largest known virus with a total diameter of about 0.75 micrometres, by injecting a beam of cooled mimivirus particles into the X-ray beam. The measurements indicate no damage during imaging and prove the concept of this imaging technique. X-ray lasers offer new capabilities in understanding the structure of biological systems, complex materials and matter under extreme conditions1,2,3,4. Very short and extremely bright, coherent X-ray pulses can be used to outrun key damage processes and obtain a single diffraction pattern from a large macromolecule, a virus or a cell before the sample explodes and turns into plasma1. The continuous diffraction pattern of non-crystalline objects permits oversampling and direct phase retrieval2. Here we show that high-quality diffraction data can be obtained with a single X-ray pulse from a non-crystalline biological sample, a single mimivirus particle, which was injected into the pulsed beam of a hard-X-ray free-electron laser, the Linac Coherent Light Source5. Calculations indicate that the energy deposited into the virus by the pulse heated the particle to over 100,000 K after the pulse had left the sample. The reconstructed exit wavefront (image) yielded 32-nm full-period resolution in a single exposure and showed no measurable damage. The reconstruction indicates inhomogeneous arrangement of dense material inside the virion. We expect that significantly higher resolutions will be achieved in such experiments with shorter and brighter photon pulses focused to a smaller area. The resolution in such experiments can be further extended for samples available in multiple identical copies.
838 citations
••
TL;DR: Initial results from a study of the interaction of soft X-ray radiation, generated by a free-electron laser, with Xe atoms and clusters are presented, finding that, whereasXe atoms become only singly ionized by the absorption of single photons, absorption in clusters is strongly enhanced.
Abstract: Intense radiation from lasers has opened up many new areas of research in physics and chemistry, and has revolutionized optical technology. So far, most work in the field of nonlinear processes has been restricted to infrared, visible and ultraviolet light, although progress in the development of X-ray lasers has been made recently. With the advent of a free-electron laser in the soft-X-ray regime below 100 nm wavelength, a new light source is now available for experiments with intense, short-wavelength radiation that could be used to obtain deeper insights into the structure of matter. Other free-electron sources with even shorter wavelengths are planned for the future. Here we present initial results from a study of the interaction of soft X-ray radiation, generated by a free-electron laser, with Xe atoms and clusters. We find that, whereas Xe atoms become only singly ionized by the absorption of single photons, absorption in clusters is strongly enhanced. On average, each atom in large clusters absorbs up to 400 eV, corresponding to 30 photons. We suggest that the clusters are heated up and electrons are emitted after acquiring sufficient energy. The clusters finally disintegrate completely by Coulomb explosion.
380 citations
••
TL;DR: Measurements indicate that current X-ray free-electron laser technology should enable structural determination from submicrometre protein crystals with atomic resolution, and the shortest apparent pulse lengths occur at the highest resolution.
Abstract: Researchers describe a mechanism capable of compressing fast and intense X-ray pulses through the rapid loss of crystalline periodicity. It is hoped that this concept, combined with X-ray free-electron laser technology, will allow scientists to obtain structural information at atomic resolutions.
309 citations
••
TL;DR: The plasma dynamics of single mesoscopic Xe particles irradiated with intense femtosecond x-ray pulses exceeding 10(16) W/cm2 from the Linac Coherent Light Source free-electron laser are investigated and show that for clusters illuminated with intense x-Ray pulses, highly charged ionization fragments in a narrow distribution are created.
Abstract: The plasma dynamics of single mesoscopic Xe particles irradiated with intense femtosecond x-ray pulses exceeding ${10}^{16}\text{ }\text{ }\mathrm{W}/{\mathrm{cm}}^{2}$ from the Linac Coherent Light Source free-electron laser are investigated. Simultaneous recording of diffraction patterns and ion spectra allows eliminating the influence of the laser focal volume intensity and particle size distribution. The data show that for clusters illuminated with intense x-ray pulses, highly charged ionization fragments in a narrow distribution are created and that the nanoplasma recombination is efficiently suppressed.
252 citations
Cited by
More filters
••
01 Oct 2019
TL;DR: Recent developments in the Phenix software package are described in the context of macromolecular structure determination using X-rays, neutrons and electrons.
Abstract: Diffraction (X-ray, neutron and electron) and electron cryo-microscopy are powerful methods to determine three-dimensional macromolecular structures, which are required to understand biological processes and to develop new therapeutics against diseases. The overall structure-solution workflow is similar for these techniques, but nuances exist because the properties of the reduced experimental data are different. Software tools for structure determination should therefore be tailored for each method. Phenix is a comprehensive software package for macromolecular structure determination that handles data from any of these techniques. Tasks performed with Phenix include data-quality assessment, map improvement, model building, the validation/rebuilding/refinement cycle and deposition. Each tool caters to the type of experimental data. The design of Phenix emphasizes the automation of procedures, where possible, to minimize repetitive and time-consuming manual tasks, while default parameters are chosen to encourage best practice. A graphical user interface provides access to many command-line features of Phenix and streamlines the transition between programs, project tracking and re-running of previous tasks.
3,268 citations
••
TL;DR: The fluidic multiplexor as discussed by the authors is a combinatorial array of binary valve patterns that exponentially increases the processing power of a network by allowing complex fluid manipulations with a minimal number of inputs.
Abstract: High-density microfluidic chips contain plumbing networks with thousands of micromechanical valves and hundreds of individually addressable chambers. These fluidic devices are analogous to electronic integrated circuits fabricated using large scale integration (LSI). A component of these networks is the fluidic multiplexor, which is a combinatorial array of binary valve patterns that exponentially increases the processing power of a network by allowing complex fluid manipulations with a minimal number of inputs. These integrated microfluidic networks can be used to construct a variety of highly complex microfluidic devices, for example the microfluidic analog of a comparator array, and a microfluidic memory storage device resembling electronic random access memories.
2,292 citations
••
TL;DR: In this article, the authors survey progress over the past 25 years in the development of microscale devices for pumping fluids and attempt to provide both a reference for micropump researchers and a resource for those outside the field who wish to identify the best micropumps for a particular application.
Abstract: We survey progress over the past 25 years in the development of microscale devices for pumping fluids. We attempt to provide both a reference for micropump researchers and a resource for those outside the field who wish to identify the best micropump for a particular application. Reciprocating displacement micropumps have been the subject of extensive research in both academia and the private sector and have been produced with a wide range of actuators, valve configurations and materials. Aperiodic displacement micropumps based on mechanisms such as localized phase change have been shown to be suitable for specialized applications. Electroosmotic micropumps exhibit favorable scaling and are promising for a variety of applications requiring high flow rates and pressures. Dynamic micropumps based on electrohydrodynamic and magnetohydrodynamic effects have also been developed. Much progress has been made, but with micropumps suitable for important applications still not available, this remains a fertile area for future research.
1,913 citations
••
[...]
TL;DR: Lipson and Steeple as mentioned in this paper interpreted X-ray powder diffraction patterns and found that powder-diffraction patterns can be represented by a set of 3-dimensional planes.
Abstract: Interpretation of X-ray Powder Diffraction Patterns . By H. Lipson and H. Steeple. Pp. viii + 335 + 3 plates. (Mac-millan: London; St Martins Press: New York, May 1970.) £4.
1,867 citations