scispace - formally typeset
Search or ask a question
Author

John Ip

Bio: John Ip is an academic researcher from University of Auckland. The author has contributed to research in topics: Atrial fibrillation & Terrorism. The author has an hindex of 18, co-authored 54 publications receiving 8055 citations. Previous affiliations of John Ip include McLaren–Greater Lansing Hospital & Sparrow Hospital.


Papers
More filters
Journal ArticleDOI
TL;DR: In patients with NYHA class II or III CHF and LVEF of 35 percent or less, amiodarone has no favorable effect on survival, whereas single-lead, shock-only ICD therapy reduces overall mortality by 23 percent.
Abstract: background Sudden death from cardiac causes remains a leading cause of death among patients with congestive heart failure (CHF). Treatment with amiodarone or an implantable cardioverter–defibrillator (ICD) has been proposed to improve the prognosis in such patients. methods We randomly assigned 2521 patients with New York Heart Association (NYHA) class II or III CHF and a left ventricular ejection fraction (LVEF) of 35 percent or less to conventional therapy for CHF plus placebo (847 patients), conventional therapy plus amiodarone (845 patients), or conventional therapy plus a conservatively programmed, shockonly, single-lead ICD (829 patients). Placebo and amiodarone were administered in a double-blind fashion. The primary end point was death from any cause. results The median LVEF in patients was 25 percent; 70 percent were in NYHA class II, and 30 percent were in class III CHF. The cause of CHF was ischemic in 52 percent and nonischemic in 48 percent. The median follow-up was 45.5 months. There were 244 deaths (29 percent) in the placebo group, 240 (28 percent) in the amiodarone group, and 182 (22 percent) in the ICD group. As compared with placebo, amiodarone was associated with a similar risk of death (hazard ratio, 1.06; 97.5 percent confidence interval, 0.86 to 1.30; P=0.53) and ICD therapy was associated with a decreased risk of death of 23 percent (0.77; 97.5 percent confidence interval, 0.62 to 0.96; P=0.007) and an absolute decrease in mortality of 7.2 percentage points after five years in the overall population. Results did not vary according to either ischemic or nonischemic causes of CHF, but they did vary according to the NYHA class. conclusions In patients with NYHA class II or III CHF and LVEF of 35 percent or less, amiodarone has no favorable effect on survival, whereas single-lead, shock-only ICD therapy reduces overall mortality by 23 percent.

5,903 citations

Journal ArticleDOI
TL;DR: The leadless cardiac pacemaker met prespecified pacing and sensing requirements in the large majority of patients, and met the primary safety end point through 6 months.
Abstract: BACKGROUND Cardiac pacemakers are limited by device-related complications, notably infection and problems related to pacemaker leads. We studied a miniaturized, fully selfcontained leadless pacemaker that is nonsurgically implanted in the right ventricle with the use of a catheter. METHODS In this multicenter study, we implanted an active-fixation leadless cardiac pacemaker in patients who required permanent single-chamber ventricular pacing. The primary efficacy end point was both an acceptable pacing threshold (≤2.0 V at 0.4 msec) and an acceptable sensing amplitude (R wave ≥5.0 mV, or a value equal to or greater than the value at implantation) through 6 months. The primary safety end point was freedom from device-related serious adverse events through 6 months. In this ongoing study, the prespecified analysis of the primary end points was performed on data from the first 300 patients who completed 6 months of followup (primary cohort). The rates of the efficacy end point and safety end point were compared with performance goals (based on historical data) of 85% and 86%, respectively. Additional outcomes were assessed in all 526 patients who were enrolled as of June 2015 (the total cohort). RESULTS The leadless pacemaker was successfully implanted in 504 of the 526 patients in the total cohort (95.8%). The intention-to-treat primary efficacy end point was met in 270 of the 300 patients in the primary cohort (90.0%; 95% confidence interval [CI], 86.0 to 93.2, P = 0.007), and the primary safety end point was met in 280 of the 300 patients (93.3%; 95% CI, 89.9 to 95.9; P<0.001). At 6 months, device-related serious adverse events were observed in 6.7% of the patients; events included device dislodgement with percutaneous retrieval (in 1.7%), cardiac perforation (in 1.3%), and pacing-threshold elevation requiring percutaneous retrieval and device replacement (in 1.3%). CONCLUSIONS The leadless cardiac pacemaker met prespecified pacing and sensing requirements in the large majority of patients. Device-related serious adverse events occurred in approximately 1 in 15 patients. (Funded by St. Jude Medical; LEADLESS II ClinicalTrials .gov number, NCT02030418.)

397 citations

Journal ArticleDOI
TL;DR: Vernakalant demonstrated rapid conversion of short-duration AF and was well tolerated and four vernakalants-related serious adverse events occurred in 3 patients.
Abstract: Background— The present study assessed the efficacy and safety of vernakalant hydrochloride (RSD1235), a novel compound, for the conversion of atrial fibrillation (AF). Methods and Results— Patients were randomized in a 2:1 ratio to receive vernakalant or placebo and were stratified by AF duration of 3 hours to 7 days (short duration) and 8 to 45 days (long duration). A first infusion of placebo or vernakalant (3 mg/kg) was given for 10 minutes, followed by a second infusion of placebo or vernakalant (2 mg/kg) 15 minutes later if AF was not terminated. The primary end point was conversion of AF to sinus rhythm for at least 1 minute within 90 minutes of the start of drug infusion in the short-duration AF group. A total of 336 patients were randomized and received treatment (short duration, n=220; long duration, n=116). Of the 145 vernakalant patients, 75 (51.7%) in the short-duration AF group converted to sinus rhythm (median time, 11 minutes) compared with 3 of the 75 placebo patients (4.0%; P<0.001). Ove...

302 citations

Journal ArticleDOI
TL;DR: In patients with implanted defibrillators, the strategy of early initiation and interruption of anticoagulation based on remotely detected AT did not prevent thromboembolism and bleeding.
Abstract: Aims Atrial tachyarrhythmias (ATs) detected by implanted devices are often atrial fibrillation or flutter (AF) associated with stroke. We hypothesized that introduction and termination of anticoagulation based upon AT monitoring would reduce both stroke and bleeding. Methods and results We randomized 2718 patients with dual-chamber and biventricular defibrillators to start and stop anticoagulation based on remote rhythm monitoring vs. usual office-based follow-up with anticoagulation determined by standard clinical criteria. The primary analysis compared the composite endpoint of stroke, systemic embolism, and major bleeding with the two strategies. The trial was stopped after 2 years median follow-up based on futility of finding a difference in primary endpoints between groups. A total of 945 patients (34.8%) developed AT, 264 meeting study anticoagulation criteria. Adjudicated atrial electrograms confirmed AF in 91%; median time to initiate anticoagulation was 3 vs. 54 days in the intervention and control groups, respectively ( P < 0.001). Primary events (2.4 vs. 2.3 per 100 patient-years) did not differ between groups (HR 1.06; 95% CI 0.75–1.51; P = 0.732). Major bleeding occurred at 1.6 vs. 1.2 per 100 patient-years (HR 1.39; 95% CI 0.89–2.17; P = 0.145). In patients with AT, thromboembolism rates were 1.0 vs. 1.6 per 100 patient-years (relative risk −35.3%; 95% CI −70.8 to 35.3%; P = 0.251). Although AT burden was associated with thromboembolism, there was no temporal relationship between AT and stroke. Conclusion In patients with implanted defibrillators, the strategy of early initiation and interruption of anticoagulation based on remotely detected AT did not prevent thromboembolism and bleeding. Clinical trial registration IMPACT ClinicalTrials.gov identifier: [NCT00559988][1] [http://clinicaltrials.gov/ct2/show/[NCT00559988][1]?term=NCT00559988&rank=1][2]. [1]: /lookup/external-ref?link_type=CLINTRIALGOV&access_num=NCT00559988&atom=%2Fehj%2Fearly%2F2015%2F04%2F22%2Feurheartj.ehv115.atom [2]: http://clinicaltrials.gov/ct2/show/NCT00559988?term=NCT00559988&rank=1

299 citations

Journal ArticleDOI
TL;DR: GLORIA-AF (Global Registry on Long-Term Oral Antithrombotic Treatment in Patients with Atrial Fibrillation) is a prospective, global registry program describing antithrombinotic t...

247 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: Authors/Task Force Members: Piotr Ponikowski* (Chairperson) (Poland), Adriaan A. Voors* (Co-Chair person) (The Netherlands), Stefan D. Anker (Germany), Héctor Bueno (Spain), John G. F. Cleland (UK), Andrew J. S. Coats (UK)

13,400 citations

Journal ArticleDOI
TL;DR: The once-in-a-lifetime treatment with Abciximab Intracoronary for acute coronary syndrome and a second dose intravenously for atrial fibrillation is recommended for adults with high blood pressure.
Abstract: ACE : angiotensin-converting enzyme ACS : acute coronary syndrome ADP : adenosine diphosphate AF : atrial fibrillation AMI : acute myocardial infarction AV : atrioventricular AIDA-4 : Abciximab Intracoronary vs. intravenously Drug Application APACHE II : Acute Physiology Aand Chronic

7,519 citations

Journal ArticleDOI
TL;DR: ACCF/AHAIAI: angiotensin-converting enzyme inhibitor as discussed by the authors, angio-catabolizing enzyme inhibitor inhibitor inhibitor (ACS inhibitor) is a drug that is used to prevent atrial fibrillation.
Abstract: ACC/AHA : American College of Cardiology/American Heart Association ACCF/AHA : American College of Cardiology Foundation/American Heart Association ACE : angiotensin-converting enzyme ACEI : angiotensin-converting enzyme inhibitor ACS : acute coronary syndrome AF : atrial fibrillation

7,489 citations

Journal ArticleDOI
TL;DR: WRITING GROUP MEMBERS Emelia J. Benjamin, MD, SCM, FAHA Michael J. Reeves, PhD Matthew Ritchey, PT, DPT, OCS, MPH Carlos J. Jiménez, ScD, SM Lori Chaffin Jordan,MD, PhD Suzanne E. Judd, PhD
Abstract: WRITING GROUP MEMBERS Emelia J. Benjamin, MD, SCM, FAHA Michael J. Blaha, MD, MPH Stephanie E. Chiuve, ScD Mary Cushman, MD, MSc, FAHA Sandeep R. Das, MD, MPH, FAHA Rajat Deo, MD, MTR Sarah D. de Ferranti, MD, MPH James Floyd, MD, MS Myriam Fornage, PhD, FAHA Cathleen Gillespie, MS Carmen R. Isasi, MD, PhD, FAHA Monik C. Jiménez, ScD, SM Lori Chaffin Jordan, MD, PhD Suzanne E. Judd, PhD Daniel Lackland, DrPH, FAHA Judith H. Lichtman, PhD, MPH, FAHA Lynda Lisabeth, PhD, MPH, FAHA Simin Liu, MD, ScD, FAHA Chris T. Longenecker, MD Rachel H. Mackey, PhD, MPH, FAHA Kunihiro Matsushita, MD, PhD, FAHA Dariush Mozaffarian, MD, DrPH, FAHA Michael E. Mussolino, PhD, FAHA Khurram Nasir, MD, MPH, FAHA Robert W. Neumar, MD, PhD, FAHA Latha Palaniappan, MD, MS, FAHA Dilip K. Pandey, MBBS, MS, PhD, FAHA Ravi R. Thiagarajan, MD, MPH Mathew J. Reeves, PhD Matthew Ritchey, PT, DPT, OCS, MPH Carlos J. Rodriguez, MD, MPH, FAHA Gregory A. Roth, MD, MPH Wayne D. Rosamond, PhD, FAHA Comilla Sasson, MD, PhD, FAHA Amytis Towfighi, MD Connie W. Tsao, MD, MPH Melanie B. Turner, MPH Salim S. Virani, MD, PhD, FAHA Jenifer H. Voeks, PhD Joshua Z. Willey, MD, MS John T. Wilkins, MD Jason HY. Wu, MSc, PhD, FAHA Heather M. Alger, PhD Sally S. Wong, PhD, RD, CDN, FAHA Paul Muntner, PhD, MHSc On behalf of the American Heart Association Statistics Committee and Stroke Statistics Subcommittee Heart Disease and Stroke Statistics—2017 Update

7,190 citations