scispace - formally typeset
Search or ask a question
Author

Joseph E. Mietus

Bio: Joseph E. Mietus is an academic researcher from Beth Israel Deaconess Medical Center. The author has contributed to research in topics: Sleep apnea & Heart rate variability. The author has an hindex of 36, co-authored 49 publications receiving 13840 citations. Previous affiliations of Joseph E. Mietus include Harvard University & Wyss Institute for Biologically Inspired Engineering.

Papers
More filters
Journal ArticleDOI
TL;DR: The newly inaugurated Research Resource for Complex Physiologic Signals (RRSPS) as mentioned in this paper was created under the auspices of the National Center for Research Resources (NCR Resources).
Abstract: —The newly inaugurated Research Resource for Complex Physiologic Signals, which was created under the auspices of the National Center for Research Resources of the National Institutes of He...

11,407 citations

Journal ArticleDOI
TL;DR: It is demonstrated that HRV analysis of ambulatory ECG recordings based on fully automated methods can have prognostic value in a population-based study and that nonlinear HRV indices may contribute prognosticvalue to complement traditional HRV measures.
Abstract: BACKGROUND: Despite much recent interest in quantification of heart rate variability (HRV), the prognostic value of conventional measures of HRV and of newer indices based on nonlinear dynamics is not universally accepted. METHODS AND RESULTS: We have designed algorithms for analyzing ambulatory ECG recordings and measuring HRV without human intervention, using robust methods for obtaining time-domain measures (mean and SD of heart rate), frequency-domain measures (power in the bands of 0.001 to 0.01 Hz [VLF], 0.01 to 0.15 Hz [LF], and 0.15 to 0.5 Hz [HF] and total spectral power [TP] over all three of these bands), and measures based on nonlinear dynamics (approximate entropy [ApEn], a measure of complexity, and detrended fluctuation analysis [DFA], a measure of long-term correlations). The study population consisted of chronic congestive heart failure (CHF) case patients and sex- and age-matched control subjects in the Framingham Heart Study. After exclusion of technically inadequate studies and those with atrial fibrillation, we used these algorithms to study HRV in 2-hour ambulatory ECG recordings of 69 participants (mean age, 71.7+/-8.1 years). By use of separate Cox proportional-hazards models, the conventional measures SD (P .3), were not. In multivariable models, DFA was of borderline predictive significance (P=.06) after adjustment for the diagnosis of CHF and SD. CONCLUSIONS: These results demonstrate that HRV analysis of ambulatory ECG recordings based on fully automated methods can have prognostic value in a population-based study and that nonlinear HRV indices may contribute prognostic value to complement traditional HRV measures.

516 citations

Journal ArticleDOI
26 Sep 1996-Nature
TL;DR: A new approach is introduced, based on the wavelet transform and an analytic signal approach, which can characterize non-stationary behaviour and elucidate the phase interactions between the different frequency components of the signal.
Abstract: BIOLOGICAL time-series analysis is used to identify hidden dynamical patterns which could yield important insights into underlying physiological mechanisms. Such analysis is complicated by the fact that biological signals are typically both highly irregular and non-stationary, that is, their statistical character changes slowly or intermittently as a result of variations in background influences1–3. Previous statistical analyses of heartbeat dynamics4–6 have identified long-range correlations and power-law scaling in the normal heartbeat, but not the phase interactions between the different frequency components of the signal. Here we introduce a new approach, based on the wavelet transform and an analytic signal approach, which can characterize non-stationary behaviour and elucidate such phase interactions. We find that, when suitably rescaled, the distributions of the variations in the beat-to-beat intervals for all healthy subjects are described by a single function stable over a wide range of timescales. However, a similar scaling function does not exist for a group with cardiopulmonary instability caused by sleep apnoea. We attribute the functional form of the scaling observed in the healthy subjects to underlying nonlinear dynamics, which seem to be essential to normal heart function. The approach introduced here should be useful in the analysis of other nonstationary biological signals.

485 citations

Journal ArticleDOI
TL;DR: High frequency heart rate spectral power and the overall complexity of heart rate dynamics are higher in women than men, and these complementary findings indicate the need to account for gender- as well as age-related differences inheart rate dynamics.

458 citations

Journal ArticleDOI
TL;DR: Application of fractal scaling analysis and related techniques provides new approaches to assessing cardiac risk and forecasting sudden cardiac death, as well as motivating development of novel physiologic models of systems that appear to be heterodynamic rather than homeostatic.

348 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: The newly inaugurated Research Resource for Complex Physiologic Signals (RRSPS) as mentioned in this paper was created under the auspices of the National Center for Research Resources (NCR Resources).
Abstract: —The newly inaugurated Research Resource for Complex Physiologic Signals, which was created under the auspices of the National Center for Research Resources of the National Institutes of He...

11,407 citations

Journal ArticleDOI
TL;DR: This survey tries to provide a structured and comprehensive overview of the research on anomaly detection by grouping existing techniques into different categories based on the underlying approach adopted by each technique.
Abstract: Anomaly detection is an important problem that has been researched within diverse research areas and application domains. Many anomaly detection techniques have been specifically developed for certain application domains, while others are more generic. This survey tries to provide a structured and comprehensive overview of the research on anomaly detection. We have grouped existing techniques into different categories based on the underlying approach adopted by each technique. For each category we have identified key assumptions, which are used by the techniques to differentiate between normal and anomalous behavior. When applying a given technique to a particular domain, these assumptions can be used as guidelines to assess the effectiveness of the technique in that domain. For each category, we provide a basic anomaly detection technique, and then show how the different existing techniques in that category are variants of the basic technique. This template provides an easier and more succinct understanding of the techniques belonging to each category. Further, for each category, we identify the advantages and disadvantages of the techniques in that category. We also provide a discussion on the computational complexity of the techniques since it is an important issue in real application domains. We hope that this survey will provide a better understanding of the different directions in which research has been done on this topic, and how techniques developed in one area can be applied in domains for which they were not intended to begin with.

9,627 citations

Journal ArticleDOI
TL;DR: A new and related complexity measure is developed, sample entropy (SampEn), and a comparison of ApEn and SampEn is compared by using them to analyze sets of random numbers with known probabilistic character, finding SampEn agreed with theory much more closely than ApEn over a broad range of conditions.
Abstract: Entropy, as it relates to dynamical systems, is the rate of information production. Methods for estimation of the entropy of a system represented by a time series are not, however, well suited to analysis of the short and noisy data sets encountered in cardiovascular and other biological studies. Pincus introduced approximate entropy (ApEn), a set of measures of system complexity closely related to entropy, which is easily applied to clinical cardiovascular and other time series. ApEn statistics, however, lead to inconsistent results. We have developed a new and related complexity measure, sample entropy (SampEn), and have compared ApEn and SampEn by using them to analyze sets of random numbers with known probabilistic character. We have also evaluated cross-ApEn and cross-SampEn, which use cardiovascular data sets to measure the similarity of two distinct time series. SampEn agreed with theory much more closely than ApEn over a broad range of conditions. The improved accuracy of SampEn statistics should make them useful in the study of experimental clinical cardiovascular and other biological time series.

6,088 citations

Journal ArticleDOI
TL;DR: The Medical Information Mart for Intensive Care (MIMIC-III) as discussed by the authors is a large, single-center database comprising information relating to patients admitted to critical care units at a large tertiary care hospital.
Abstract: MIMIC-III ('Medical Information Mart for Intensive Care') is a large, single-center database comprising information relating to patients admitted to critical care units at a large tertiary care hospital. Data includes vital signs, medications, laboratory measurements, observations and notes charted by care providers, fluid balance, procedure codes, diagnostic codes, imaging reports, hospital length of stay, survival data, and more. The database supports applications including academic and industrial research, quality improvement initiatives, and higher education coursework.

4,056 citations