Juan M. Bueno

Bio: Juan M. Bueno is an academic researcher from University of Murcia. The author has contributed to research in topics: Wavefront & Adaptive optics. The author has an hindex of 16, co-authored 97 publications receiving 700 citations.


Papers
More filters
Journal ArticleDOI
TL;DR: This work demonstrates a simplified arrangement for spatiotemporal ultrashort pulse characterization called Hartmann-Shack assisted, multidimensional, shaper-based technique for electric-field reconstruction, which employs an acousto-optic pulse shaper in combination with a second-order nonlinear crystal and a Hartmann/Shack wavefront sensor.
Abstract: We demonstrate a simplified arrangement for spatiotemporal ultrashort pulse characterization called Hartmann–Shack assisted, multidimensional, shaper-based technique for electric-field reconstruction. It employs an acousto-optic pulse shaper in combination with a second-order nonlinear crystal and a Hartmann–Shack wavefront sensor. The shaper is used as a tunable bandpass filter, and the wavefronts and intensities of quasimonochromatic spectral slices of the pulse are obtained using the Hartmann–Shack wavefront sensor. The wavefronts and intensities of the spectral slices are related to one another using shaper-assisted frequency-resolved optical gating measurements, performed at particular points in the beam. This enables a three-dimensional reconstruction of the amplitude and phase of the pulse. We present some example pulse measurements and discuss the operating parameters of the device.

40 citations

Journal ArticleDOI
TL;DR: The structure and organization of the chicken retina has been investigated with an adaptive optics multiphoton imaging microscope in a backward configuration and the density of photoreceptors and ganglion cells layer were directly estimated from the images as a function of the retinal eccentricity.
Abstract: The structure and organization of the chicken retina has been investigated with an adaptive optics multiphoton imaging microscope in a backward configuration. Non-stained flat-mounted retinal tissues were imaged at different depths, from the retinal nerve fiber layer to the outer segment, by detecting the intrinsic nonlinear fluorescent signal. From the stacks of images corresponding to the different retinal layers, volume renderings of the entire retina were reconstructed. The density of photoreceptors and ganglion cells layer were directly estimated from the images as a function of the retinal eccentricity. The maximum anatomical resolving power at different retinal eccentricities was also calculated. This technique could be used for a better characterization of retinal alterations during myopia development, and may be useful for visualization of retinal pathologies and intoxication during pharmacological studies.

30 citations

Journal ArticleDOI
TL;DR: A wavefront sensorless adaptive optics technique was combined with a custom‐made multiphoton microscope to correct for specimen‐induced aberrations and a noticeable dominance of spherical aberration was found.
Abstract: A wavefront sensorless adaptive optics technique was combined with a custom-made multiphoton microscope to correct for specimen-induced aberrations. A liquid-crystal-on-silicon (LCoS) modulator was used to systematically generate Zernike modes during image recording. The performance of the instrument was evaluated in samples providing different nonlinear signals and the benefit of correcting higher order aberrations was always noticeable (in both contrast and resolution). The optimum aberration pattern was stable in time for the samples here involved. For a particular depth location within the sample, the wavefront to be precompensated was independent on the size of the imaged area (up to ∼ 360 × 360 μm(2)). The mode combination optimizing the recorded image depended on the Zernike correction control sequence; however, the final images hardly differed. At deeper locations, a noticeable dominance of spherical aberration was found. The influence of other aberration terms was also compared to the effect of the spherical aberration.

28 citations

Journal ArticleDOI
TL;DR: A novel compact 2P microscope for non-contact imaging of the anterior part of the living human eye and 2P images of the in vivo human cornea, the sclera and the trabecular meshwork are shown for the very first time.
Abstract: Two-photon (2P) microscopy is a powerful tool for imaging and exploring label-free biological tissues at high resolution. Although this type of microscopy has been demonstrated in ex vivo ocular tissues of both humans and animal models, imaging the human eye in vivo has always been challenging. This work presents a novel compact 2P microscope for non-contact imaging of the anterior part of the living human eye. The performance of the instrument was tested and the maximum permissible exposure to protect ocular tissues established. To the best of our knowledge, 2P images of the in vivo human cornea, the sclera and the trabecular meshwork are shown for the very first time. Acquired images are of enough quality to visualize collagen arrangement and morphological features of clinical interest. Future implementations of this technique may constitute a potential tool for early diagnosis of ocular diseases at submicron scale.

28 citations

Journal ArticleDOI
TL;DR: In this paper, the direct (GL) and reverse (GLR) indices of linear polarization for an optical system are calculated using the concept of the degree of linear polarisation for the light beam emerging from the system and they are expressed as a function of the elements of the corresponding Mueller matrix.
Abstract: Direct (GL)and reverse ( GLR)indices of linear polarization for an optical system are presented. These parameters have been calculated using the concept of the degree of linear polarization for the light beam emerging from the system and they are expressed as a function of the elements of the corresponding Mueller matrix. Values of GL and GLR for pure and combinations of polarization elements have been calculated. Real examples such as the human eye and an in vitro cornea are also shown.

26 citations


Cited by
More filters
Journal Article
TL;DR: In this article, a fast Fourier transform method of topography and interferometry is proposed to discriminate between elevation and depression of the object or wave-front form, which has not been possible by the fringe-contour generation techniques.
Abstract: A fast-Fourier-transform method of topography and interferometry is proposed. By computer processing of a noncontour type of fringe pattern, automatic discrimination is achieved between elevation and depression of the object or wave-front form, which has not been possible by the fringe-contour-generation techniques. The method has advantages over moire topography and conventional fringe-contour interferometry in both accuracy and sensitivity. Unlike fringe-scanning techniques, the method is easy to apply because it uses no moving components.

3,742 citations

Journal ArticleDOI
TL;DR: The purpose of this article was to survey the use of the Bonferroni correction in research articles published in three optometric journals and to provide advice to authors contemplating multiple testing.
Abstract: PURPOSE: The Bonferroni correction adjusts probability (p) values because of the increased risk of a type I error when making multiple statistical tests. The routine use of this test has been criticised as deleterious to sound statistical judgment, testing the wrong hypothesis, and reducing the chance of a type I error but at the expense of a type II error; yet it remains popular in ophthalmic research. The purpose of this article was to survey the use of the Bonferroni correction in research articles published in three optometric journals, viz. Ophthalmic & Physiological Optics, Optometry & Vision Science, and Clinical & Experimental Optometry, and to provide advice to authors contemplating multiple testing. RECENT FINDINGS: Some authors ignored the problem of multiple testing while others used the method uncritically with no rationale or discussion. A variety of methods of correcting p values were employed, the Bonferroni method being the single most popular. Bonferroni was used in a variety of circumstances, most commonly to correct the experiment-wise error rate when using multiple 't' tests or as a post-hoc procedure to correct the family-wise error rate following analysis of variance (anova). Some studies quoted adjusted p values incorrectly or gave an erroneous rationale. SUMMARY: Whether or not to use the Bonferroni correction depends on the circumstances of the study. It should not be used routinely and should be considered if: (1) a single test of the 'universal null hypothesis' (Ho ) that all tests are not significant is required, (2) it is imperative to avoid a type I error, and (3) a large number of tests are carried out without preplanned hypotheses.

1,749 citations

Journal Article
TL;DR: In this article, a polarization-sensitive optical coherence-domain reflectometer capable of characterizing the phase retardation between orthogonal linear polarization modes at each reflection point in a birefringent sample is presented.
Abstract: We present a polarization-sensitive optical coherence-domain reflectometer capable of characterizing the phase retardation between orthogonal linear polarization modes at each reflection point in a birefringent sample. The device is insensitive to the rotation of the sample in the plane perpendicular to ranging. Phase measurement accuracy is ±0.86°, but the reflectometer can distinguish local variations in birefringence as small as 0.05° with a distance resolution of 10.8 μm and a dynamic range of 90 dB. Birefringence-sensitive ranging in a wave plate, an electro-optic modulator, and a calf coronary artery is demonstrated.

601 citations

Journal ArticleDOI
TL;DR: How technologies such as deformable mirrors and spatial light modulators, which compensate for aberrations by locally controlling the wavefront of a light wave, are now improving the performance of multiphoton, confocal, widefield and super-resolution microscopes are reviewed.
Abstract: Adaptive optics is becoming a valuable tool for high resolution microscopy, providing correction for aberrations introduced by the refractive index structure of specimens. This is proving particularly promising for applications that require images from deep within biological tissue specimens. We review recent developments in adaptive microscopy, including methods and applications. A range of advances in different microscope modalities is covered and prospects for the future are discussed. Adaptive optics is used to improve image quality across a wide range of microscopy techniques. Martin Booth from the University of Oxford in the UK reviews how technologies such as deformable mirrors and spatial light modulators, which compensate for aberrations by locally controlling the wavefront of a light wave, are now improving the performance of multiphoton, confocal, widefield and super-resolution microscopes. The benefits of such improvements are especially appealing for images captured from within biological tissue (focal distances of tens to hundreds of micrometres), where low-order aberrations associated with smooth phase variations occur. One future challenge is the development of efficient measurement and correction schemes for higher-order phase variations.

522 citations

Journal Article
TL;DR: It was found that chirality plays a significant role in the mechanism of contrast generation, and it is also shown that SHIM is highly sensitive to membrane potential, with a depolarization of 25 mV resulting in an approximately twofold loss of signal intensity.
Abstract: By adapting a laser scanning microscope with a titanium sapphire femtosecond pulsed laser and transmission optics, we are able to produce live cell images based on the nonlinear optical phenomenon of second harmonic generation (SHG). Second harmonic imaging (SHIM) is an ideal method for probing membranes of living cells because it offers the high resolution of nonlinear optical microscopy with the potential for near-total avoidance of photobleaching and phototoxicity. The technique has been implemented on three cell lines labeled with membrane-staining dyes that have large nonlinear optical coefficients. The images can be obtained within physiologically relevant time scales. Both achiral and chiral dyes were used to compare image formation for the case of single- and double-leaflet staining, and it was found that chirality plays a significant role in the mechanism of contrast generation. It is also shown that SHIM is highly sensitive to membrane potential, with a depolarization of 25 mV resulting in an approximately twofold loss of signal intensity.

456 citations