scispace - formally typeset
Search or ask a question
Author

Juan Sieira

Other affiliations: Université libre de Bruxelles
Bio: Juan Sieira is an academic researcher from Vrije Universiteit Brussel. The author has contributed to research in topics: Brugada syndrome & Medicine. The author has an hindex of 24, co-authored 101 publications receiving 1924 citations. Previous affiliations of Juan Sieira include Université libre de Bruxelles.

Papers published on a yearly basis

Papers
More filters
Journal ArticleDOI
TL;DR: ICD therapy was an effective strategy in Brugada syndrome, treating potentially lethal arrhythmias in 17% of patients during long-term follow-up, and risk stratification by electrophysiologic study may identify asymptomatic patients at risk for arrhythmic events and could be helpful in investigating syncope not related to VAs.

162 citations

Journal ArticleDOI
TL;DR: A single 3-minute freeze is highly effective, determining an atrial tachyarrhythmia freedom of 80.4% at 1-year follow-up, and Routine use of an "insurance freeze" may not be needed.

159 citations

Journal ArticleDOI
TL;DR: Investigation of long-term prognosis and risk stratification of BS patients found patients remain at risk many years after diagnosis, and early SCD in first-degree relatives and SND are risk factors for arrhythmic events.
Abstract: Aims Risk stratification in Brugada Syndrome (BS) remains challenging. Arrhythmic events can occur life-long and studies with long follow-ups are sparse. The aim of our study was to investigate long-term prognosis and risk stratification of BS patients. Methods and results A single centre consecutive cohort of 400 BS patients was included and analysed. Mean age was 41.1 years, 78 patients (19.5%) had a spontaneous type I electrocardiogram (ECG). Clinical presentation was aborted sudden cardiac death (SCD) in 20 patients (5.0%), syncope in 111 (27.8%) and asymptomatic in 269 (67.3%). Familial antecedents of SCD were found in 184 individuals (46.0%), in 31 (7.8%) occurred in first-degree relatives younger than 35 years. An implantable cardioverter defibrillator (ICD) was placed in 176 (44.0%). During a mean follow-up of 80.7 months, 34 arrhythmic events occurred (event rate: 1.4% year). Variables significantly associated to events were: presentation as aborted SCD (Hazard risk [HR] 20.0), syncope (HR 3.7), spontaneous type I (HR 2.7), male gender (HR 2.7), early SCD in first-degree relatives (HR 2.9), SND (HR 5.0), inducible VA (HR 4.7) and proband status (HR 2.1). A score including ECG pattern, early familial SCD antecedents, inducible electrophysiological study, presentation as syncope or as aborted SCD and SND had a predictive performance of 0.82. A score greater than 2 conferred a 5-year event probability of 9.2%. Conclusions BS patients remain at risk many years after diagnosis. Early SCD in first-degree relatives and SND are risk factors for arrhythmic events. A simple risk score might help in the stratification and management of BS patients.

144 citations

Journal ArticleDOI
TL;DR: More refined phrenic nerve monitoring during right-sided pulmonary vein ablation and less vigorous wedging maneuvers in the pulmonary vein ostia might significantly reduce the occurrence of right PNP with the second-generation cryoballoon ablation Arctic Front Advance.

128 citations

Journal ArticleDOI
01 Apr 2015-Europace
TL;DR: Atrial tachyarrhythmias occurrence during BP and longer time of PersAF seem to be significant predictors of arrhythmia recurrences after the index procedure, which is associated with shorter procedure time and radiation exposure as compared with RFCA.
Abstract: Aims To assess the 1 year efficacy of pulmonary vein isolation (PVI) as index procedure for persistent atrial fibrillation (PersAF) comparing conventional radiofrequency irrigated-tip catheter ablation (RFCA) using contact-force technology and ablation using the second-generation cryoballoon (CB-AdvA). Methods and results One hundred consecutive patients (74 male, 74%; mean age 62.4 ± 9.6 years) with drug-refractory PersAF undergoing PVI using RFCA and CB-AdvA were enrolled. Follow-up was based on outpatient clinic visits including Holter-electrocardiograms. Recurrence of atrial tachyarrhythmias (ATas) was defined as a symptomatic or documented episode >30 s. Among 100 patients, 50 underwent RFCA whereas 50 CB-AdvA. Mean procedure and fluoroscopy times were 90.5 ± 41.7 vs. 140.2 ± 46.9 min and 14.5 ± 6.6 vs. 19.8 ± 6.8 min in the CB-Adv and in the RFCA group, respectively ( P < 0.01). At 1 year follow-up, after a 3 months blanking period (BP), freedom from ATas off-drugs after a single procedure was 60% (28/50 patients) in the CB-Adv and 56% (27/50 patients) in the RFCA group ( P = 0.71). Multivariate analysis demonstrated that PersAF duration ( P = 0.01) and relapses during BP ( P = 0.02) were independent predictors of ATa recurrences following the index procedure. Conclusion Freedom from ATas following PersAF ablation with RFCA and CB-Adv is comparable at 1 year follow-up after a single procedure. Ablation with the CB-Adv is associated with shorter procedure time and radiation exposure as compared with RFCA. Atrial tachyarrhythmias occurrence during BP and longer time of PersAF seem to be significant predictors of arrhythmia recurrences after the index procedure.

101 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: The content of these European Society of Cardiology (ESC) Guidelines has been published for personal and educational use only and no commercial use is authorized.
Abstract: Supplementary Table 9, column 'Edoxaban', row 'eGFR category', '95 mL/min' (page 15). The cell should be coloured green instead of yellow. It should also read "60 mg"instead of "60 mg (use with caution in 'supranormal' renal function)."In the above-indicated cell, a footnote has also been added to state: "Edoxaban should be used in patients with high creatinine clearance only after a careful evaluation of the individual thromboembolic and bleeding risk."Supplementary Table 9, column 'Edoxaban', row 'Dose reduction in selected patients' (page 16). The cell should read "Edoxaban 60 mg reduced to 30 mg once daily if any of the following: creatinine clearance 15-50 mL/min, body weight <60 kg, concomitant use of dronedarone, erythromycin, ciclosporine or ketokonazole"instead of "Edoxaban 60 mg reduced to 30 mg once daily, and edoxaban 30 mg reduced to 15mg once daily, if any of the following: creatinine clearance of 30-50 mL/min, body weight <60 kg, concomitant us of verapamil or quinidine or dronedarone."

4,285 citations

Journal ArticleDOI
TL;DR: In this article, the authors proposed AMIOdarone versus implantable cardioverter-defibrillator (ICD-DV) for the treatment of atrial fibrillation.
Abstract: ACC : American College of Cardiology ACE : angiotensin-converting enzyme ACS : acute coronary syndrome AF : atrial fibrillation AGNES : Arrhythmia Genetics in the Netherlands AHA : American Heart Association AMIOVIRT : AMIOdarone Versus Implantable cardioverter-defibrillator:

2,830 citations

Journal ArticleDOI
TL;DR: This poster presents a probabilistic procedure to determine the best method for selecting a single drug to treat atrial fibrillation-like symptoms in patients with a history of atrialfibrillation.
Abstract: 2015 ESC Guidelines for the Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death

2,109 citations

Journal ArticleDOI
TL;DR: This 2017 Consensus Statement is to provide a state-of-the-art review of the field of catheter and surgical ablation of AF and to report the findings of a writing group, convened by these five international societies.

1,626 citations

Journal ArticleDOI
01 Nov 2015-Europace
TL;DR: In this article, the authors proposed AMIOdarone versus implantable cardioverter-defibrillator (ICD-DV) for the treatment of atrial fibrillation.
Abstract: ACC : American College of Cardiology ACE : angiotensin-converting enzyme ACS : acute coronary syndrome AF : atrial fibrillation AGNES : Arrhythmia Genetics in the Netherlands AHA : American Heart Association AMIOVIRT : AMIOdarone Versus Implantable cardioverter-defibrillator:

1,513 citations