Author
K. J. Palladino
Other affiliations: Ohio State University, SLAC National Accelerator Laboratory, Stanford University ...read more
Bio: K. J. Palladino is an academic researcher from University of Wisconsin-Madison. The author has contributed to research in topics: Neutrino & Dark matter. The author has an hindex of 29, co-authored 79 publications receiving 5457 citations. Previous affiliations of K. J. Palladino include Ohio State University & SLAC National Accelerator Laboratory.
Topics: Neutrino, Dark matter, Xenon, Physics, Neutrino detector
Papers published on a yearly basis
Papers
More filters
••
Case Western Reserve University1, University of Wisconsin-Madison2, Imperial College London3, South Dakota School of Mines and Technology4, University of Maryland, College Park5, University of California, Berkeley6, Lawrence Livermore National Laboratory7, University of Coimbra8, University of South Dakota9, Yale University10, University of California, Santa Barbara11, Brown University12, University of California, Davis13, Lawrence Berkeley National Laboratory14, University College London15, University of Rochester16, SLAC National Accelerator Laboratory17, Texas A&M University18, State University of New York System19, University of Edinburgh20
TL;DR: This search yields no evidence of WIMP nuclear recoils and constraints on spin-independent weakly interacting massive particle (WIMP)-nucleon scattering using a 3.35×10^{4} kg day exposure of the Large Underground Xenon experiment are reported.
Abstract: We report constraints on spin-independent weakly interacting massive particle (WIMP)-nucleon scattering using a 3.35×10^{4} kg day exposure of the Large Underground Xenon (LUX) experiment. A dual-phase xenon time projection chamber with 250 kg of active mass is operated at the Sanford Underground Research Facility under Lead, South Dakota (USA). With roughly fourfold improvement in sensitivity for high WIMP masses relative to our previous results, this search yields no evidence of WIMP nuclear recoils. At a WIMP mass of 50 GeV c^{-2}, WIMP-nucleon spin-independent cross sections above 2.2×10^{-46} cm^{2} are excluded at the 90% confidence level. When combined with the previously reported LUX exposure, this exclusion strengthens to 1.1×10^{-46} cm^{2} at 50 GeV c^{-2}.
1,844 citations
••
Case Western Reserve University1, Imperial College London2, South Dakota School of Mines and Technology3, University of Maryland, College Park4, University of Edinburgh5, Yale University6, Lawrence Livermore National Laboratory7, University of California, Santa Barbara8, Brown University9, University of South Dakota10, University of California, Davis11, University of Coimbra12, Lawrence Berkeley National Laboratory13, University College London14, University of Rochester15, University of California, Berkeley16, SLAC National Accelerator Laboratory17, Texas A&M University18, State University of New York System19
TL;DR: This new analysis incorporates several advances: single-photon calibration at the scintillation wavelength, improved event-reconstruction algorithms, a revised background model including events originating on the detector walls in an enlarged fiducial volume, and new calibrations from decays of an injected tritium β source and from kinematically constrained nuclear recoils down to 1.1 keV.
Abstract: We present constraints on weakly interacting massive particles (WIMP)-nucleus scattering from the 2013 data of the Large Underground Xenon dark matter experiment, including 1.4×10^{4} kg day of search exposure. This new analysis incorporates several advances: single-photon calibration at the scintillation wavelength, improved event-reconstruction algorithms, a revised background model including events originating on the detector walls in an enlarged fiducial volume, and new calibrations from decays of an injected tritium β source and from kinematically constrained nuclear recoils down to 1.1 keV. Sensitivity, especially to low-mass WIMPs, is enhanced compared to our previous results which modeled the signal only above a 3 keV minimum energy. Under standard dark matter halo assumptions and in the mass range above 4 GeV c^{-2}, these new results give the most stringent direct limits on the spin-independent WIMP-nucleon cross section. The 90% C.L. upper limit has a minimum of 0.6 zb at 33 GeV c^{-2} WIMP mass.
460 citations
••
Case Western Reserve University1, Stanford University2, SLAC National Accelerator Laboratory3, University of Wisconsin-Madison4, Imperial College London5, South Dakota School of Mines and Technology6, University of Maryland, College Park7, University of Edinburgh8, Yale University9, University of California, Berkeley10, Lawrence Livermore National Laboratory11, Lawrence Berkeley National Laboratory12, University of Coimbra13, University of South Dakota14, Pennsylvania State University15, University of California, Santa Barbara16, Brown University17, University of California, Davis18, University College London19, University of Rochester20, State University of New York System21, University of Massachusetts Amherst22, Texas A&M University23
TL;DR: The spin-dependent WIMP-neutron limit is the most sensitive constraint to date.
Abstract: We present experimental constraints on the spin-dependent WIMP-nucleon elastic cross sections from the total 129.5 kg yr exposure acquired by the Large Underground Xenon experiment (LUX), operating at the Sanford Underground Research Facility in Lead, South Dakota (USA). A profile likelihood ratio analysis allows 90% C.L. upper limits to be set on the WIMP-neutron (WIMP-proton) cross section of σ_{n}=1.6×10^{-41} cm^{2} (σ_{p}=5×10^{-40} cm^{2}) at 35 GeV c^{-2}, almost a sixfold improvement over the previous LUX spin-dependent results. The spin-dependent WIMP-neutron limit is the most sensitive constraint to date.
249 citations
••
TL;DR: The Antarctic Impulsive Transient Antenna (ANITA) completed its second long-duration balloon flight in January 2009, with 31 days aloft (28.5 live days) over Antarctica.
Abstract: The Antarctic Impulsive Transient Antenna (ANITA) completed its second Long Duration Balloon flight in January 2009, with 31 days aloft (28.5 live days) over Antarctica. ANITA searches for impulsive coherent radio Cherenkov emission from 200 to 1200 MHz, arising from the Askaryan charge excess in ultrahigh energy neutrino-induced cascades within Antarctic ice. This flight included significant improvements over the first flight in payload sensitivity, efficiency, and flight trajectory. Analysis of in-flight calibration pulses from surface and subsurface locations verifies the expected sensitivity. In a blind analysis, we find 2 surviving events on a background, mostly anthropogenic, of 0.97{+-}0.42 events. We set the strongest limit to date for 10{sup 18}-10{sup 21} eV cosmic neutrinos, excluding several current cosmogenic neutrino models.
232 citations
••
TL;DR: Lux-ZEPLIN (LZ) as mentioned in this paper is a next-generation dark matter direct detection experiment that will operate 4850 feet underground at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA using a two-phase xenon detector with an active mass of 7 tonnes.
Abstract: LUX-ZEPLIN (LZ) is a next-generation dark matter direct detection experiment that will operate 4850 feet underground at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA Using a two-phase xenon detector with an active mass of 7 tonnes, LZ will search primarily for low-energy interactions with weakly interacting massive particles (WIMPs), which are hypothesized to make up the dark matter in our galactic halo In this paper, the projected WIMP sensitivity of LZ is presented based on the latest background estimates and simulations of the detector For a 1000 live day run using a 56-tonne fiducial mass, LZ is projected to exclude at 90% confidence level spin-independent WIMP-nucleon cross sections above 14 × 10-48cm2 for a 40 GeV/c2 mass WIMP Additionally, a 5σ discovery potential is projected, reaching cross sections below the exclusion limits of recent experiments For spin-dependent WIMP-neutron(-proton) scattering, a sensitivity of 23 × 10−43 cm2 (71 × 10−42 cm2) for a 40 GeV/c2
mass WIMP is expected With underground installation well underway, LZ is on track for commissioning at SURF in 2020
231 citations
Cited by
More filters
••
Columbia University1, University of Amsterdam2, University of Bologna3, University of Mainz4, University of Münster5, University of Coimbra6, New York University Abu Dhabi7, University of Zurich8, Stockholm University9, Rensselaer Polytechnic Institute10, Max Planck Society11, Weizmann Institute of Science12, University of Freiburg13, University of Nantes14, University of California, San Diego15, University of Chicago16, Purdue University17, Rice University18, Pierre-and-Marie-Curie University19, University of California, Los Angeles20
TL;DR: In this article, a search for weakly interacting massive particles (WIMPs) using 278.8 days of data collected with the XENON1T experiment at LNGS is reported.
Abstract: We report on a search for weakly interacting massive particles (WIMPs) using 278.8 days of data collected with the XENON1T experiment at LNGS. XENON1T utilizes a liquid xenon time projection chamber with a fiducial mass of (1.30±0.01) ton, resulting in a 1.0 ton yr exposure. The energy region of interest, [1.4,10.6] keVee ([4.9,40.9] keVnr), exhibits an ultralow electron recoil background rate of [82-3+5(syst)±3(stat)] events/(ton yr keVee). No significant excess over background is found, and a profile likelihood analysis parametrized in spatial and energy dimensions excludes new parameter space for the WIMP-nucleon spin-independent elastic scatter cross section for WIMP masses above 6 GeV/c2, with a minimum of 4.1×10-47 cm2 at 30 GeV/c2 and a 90% confidence level.
1,808 citations
•
[...]
TL;DR: Development of this more comprehensive model of the behavior of light draws upon the use of tools traditionally available to the electrical engineer, such as linear system theory and the theory of stochastic processes.
Abstract: Course Description This is an advanced course in which we explore the field of Statistical Optics. Topics covered include such subjects as the statistical properties of natural (thermal) and laser light, spatial and temporal coherence, effects of partial coherence on optical imaging instruments, effects on imaging due to randomly inhomogeneous media, and a statistical treatment of the detection of light. Development of this more comprehensive model of the behavior of light draws upon the use of tools traditionally available to the electrical engineer, such as linear system theory and the theory of stochastic processes.
1,364 citations
••
Columbia University1, University of Amsterdam2, University of Mainz3, University of Coimbra4, New York University Abu Dhabi5, University of Zurich6, Stockholm University7, Rensselaer Polytechnic Institute8, Max Planck Society9, Weizmann Institute of Science10, University of Freiburg11, Purdue University12, University of Nantes13, University of Bologna14, University of California, San Diego15, University of Münster16, University of Chicago17, Rice University18, Pierre-and-Marie-Curie University19, University of California, Los Angeles20
TL;DR: The first dark matter search results from XENON1T, a ∼2000-kg-target-mass dual-phase (liquid-gas) xenon time projection chamber in operation at the Laboratori Nazionali del Gran Sasso in Italy, are reported and a profile likelihood analysis shows that the data are consistent with the background-only hypothesis.
Abstract: We report the first dark matter search results from XENON1T, a ∼2000-kg-target-mass dual-phase (liquid-gas) xenon time projection chamber in operation at the Laboratori Nazionali del Gran Sasso in Italy and the first ton-scale detector of this kind The blinded search used 342 live days of data acquired between November 2016 and January 2017 Inside the (1042±12)-kg fiducial mass and in the [5,40] keVnr energy range of interest for weakly interacting massive particle (WIMP) dark matter searches, the electronic recoil background was (193±025)×10-4 events/(kg×day×keVee), the lowest ever achieved in such a dark matter detector A profile likelihood analysis shows that the data are consistent with the background-only hypothesis We derive the most stringent exclusion limits on the spin-independent WIMP-nucleon interaction cross section for WIMP masses above 10 GeV/c2, with a minimum of 77×10-47 cm2 for 35-GeV/c2 WIMPs at 90% CL
1,061 citations