scispace - formally typeset
Search or ask a question
Author

László Módis

Other affiliations: Hungarian Academy of Sciences
Bio: László Módis is an academic researcher from University of Debrecen. The author has contributed to research in topics: Cornea & Scheimpflug principle. The author has an hindex of 28, co-authored 136 publications receiving 3028 citations. Previous affiliations of László Módis include Hungarian Academy of Sciences.


Papers
More filters
Journal ArticleDOI
TL;DR: The present report evaluates the clinical outcome of 36 patients followed for two to seven years after a mosaic autogenous osteochondral transplantation from a non or less weight bearing portion of the knee to the ipsilateral talus, which supports the premise of lasting relief of symptoms and prevention of ankle arthrosis.
Abstract: An osteochondral defect (OCD) is known as a symptomatic lesion causing pain, recurrent synovitis, and altered joint mechanics most commonly in a weightbearing joint. Loose bodies may develop, which...

345 citations

Journal Article
TL;DR: Autologous osteochondral mosaicplasty appears to be an alternative for the treatment of small and medium-sized focal chondral and osteochondrals defects of the weight- bearing surfaces of the knee and other weight-bearing synovial joints.
Abstract: BACKGROUND: The successful treatment of chondral and osteochondral defects of the weight-bearing surfaces is a challenge for orthopaedic surgeons. Autologous osteochondral transplantation is one method that can be used to create hyaline or hyaline-like repair in the defect area. This paper describes the results after ten years of clinical experience with autologous osteochondral mosaicplasty. METHODS: Clinical scores, imaging techniques, arthroscopy, histological examination of biopsy samples, and cartilage stiffness measurements were used to evaluate the clinical outcomes and quality of the transplanted cartilage in 831 patients undergoing mosaicplasty. RESULTS: According to these investigations, good-to-excellent results were achieved in 92% of the patients treated with femoral condylar implantations, 87% of those treated with tibial resurfacing, 79% of those treated with patellar and/or trochlear mosaicplasties, and 94% of those treated with talar procedures. Long-term donor-site disturbances, assessed with use of the Bandi score, showed that patients had 3% morbidity after mosaicplasty. Sixty-nine of eighty-three patients who were followed arthroscopically showed congruent gliding surfaces, histological evidence of the survival of the transplanted hyaline cartilage, and fibrocartilage filling of the donor sites. Complications of the surgery included four deep infections and thirty-six painful postoperative hemarthroses. CONCLUSIONS: On the basis of these promising results and those of other similar studies, autologous osteochondral mosaicplasty appears to be an alternative for the treatment of small and medium-sized focal chondral and osteochondral defects of the weight-bearing surfaces of the knee and other weight-bearing synovial joints.

256 citations

Journal ArticleDOI
TL;DR: The rationale, indications, operative technique, results, and limitations of mosaicplasty in the athlete are presented and discussed in this paper, where the autogenous osteochondral grafting mosaplasty has been used to treat traumatic chondral injuries for the past six years.

227 citations

Journal ArticleDOI
TL;DR: Evaluating the repeatability and reliability of a recently introduced swept‐source Fourier‐domain anterior segment optical coherence tomography (AS‐OCT) system and a high‐resolution Scheimpflug camera found repeatability was better in healthy eyes than in keratoconic eyes with both instruments.
Abstract: Purpose To evaluate the repeatability and reliability of a recently introduced swept-source Fourier-domain anterior segment optical coherence tomography (AS-OCT) system and a high-resolution Scheimpflug camera and to assess the agreement between the 2 instruments when measuring healthy eyes and eyes with keratoconus. Setting Department of Ophthalmology, Medical and Health Science Center, University of Debrecen, Debrecen, Hungary. Design Evaluation of diagnostic test or technology. Methods Three consecutive series of anterior segment images were taken with AS-OCT (Casia SS-1000) followed by rotating Scheimpflug imaging (Pentacam high resolution). Axial keratometry in the steep and flat meridians and astigmatism values were recorded. Pachymetry in the apex, center, and the thinnest position and anterior chamber depth (ACD) measurements were also taken. Results This study enrolled 57 healthy volunteers (57 eyes) and 56 patients (84 eyes) with keratoconus. Significant difference was found in all measured anterior segment parameters between normal eyes and keratoconic eyes ( P Conclusions Significant differences in keratometry, pachymetry, and ACD results were found between AS-OCT and Scheimpflug imaging. However, the repeatability of the measurements was comparable. Financial Disclosure No author has a financial or proprietary interest in any material or method mentioned.

127 citations

Journal ArticleDOI
TL;DR: The CorVis ST showed high repeatability for only IOP and pachymetric values and the device allows for conducting clinical examinations and screening for surgeries altering ocular biomechanical properties with some form of averaging of multiple measurements.
Abstract: PURPOSE To analyze the repeatability of a new device measuring ocular biomechanical properties, central corneal thickness (CCT), and intraocular pressure (IOP) and to investigate these parameters and their correlations in healthy eyes. METHODS Three consecutive measurements were performed on each eye using the CorVis ST device (Oculus Optikgerate, Inc., Wetzler, Germany). Ten specific parameters, CCT, and IOP were measured. Biometric data were recorded with IOLMaster (Carl Zeiss Meditec, Jena, Germany). RESULTS This study comprised 75 eyes of 75 healthy volunteers (mean age: 61.24 ± 15.72 years). Mean IOP was 15.02 ± 2.90 mm Hg and mean CCT was 556.33 ± 33.13 μm. Intraclass correlation coefficient (ICC) was 0.865 for IOP and 0.970 for CCT, and coefficient of variation was 0.069 for IOP and 0.008 for CCT. ICC was 0.758 for maximum amplitude at highest concavity and 0.784 for first applanation time, and less than 0.6 for all other parameters. The device-specific data showed no significant relationship with age and axial length. Flattest and steepest keratometric values and IOP showed a significant correlation with the 10 device-specific parameters. CONCLUSIONS The CorVis ST showed high repeatability for only IOP and pachymetric values. Single measurements are not reliable for the 10 device-specific parameters. The device allows for conducting clinical examinations and screening for surgeries altering ocular biomechanical properties with some form of averaging of multiple measurements.

121 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: The existence of many new and encouraging biological approaches to cartilage repair justifies the future investment of time and money in this research area, particularly given the extremely high socio-economic importance of such therapeutic strategies in the prevention and treatment of these common joint diseases and traumas.

1,868 citations

Journal ArticleDOI
TL;DR: The "normal" central corneal thickness (CCT) value in human corneas was determined based on reported literature values for within-study average CCT values, and the reported impact of physiological variables, contact lens wear, pharmaceuticals, ocular disease, and ophthalmic surgery on CCT was assessed.

1,323 citations

Journal ArticleDOI
TL;DR: The role of the Tear Film and Ocular Surface Society (TFOS) Dry Eye Workshop (DEWS) II Diagnostic Methodology Subcommittee was to identify tests used to diagnose and monitor dry eye disease (DED) to identify those most appropriate to fulfil the definition of DED and its sub-classifications.
Abstract: The role of the Tear Film and Ocular Surface Society (TFOS) Dry Eye Workshop (DEWS) II Diagnostic Methodology Subcommittee was 1) to identify tests used to diagnose and monitor dry eye disease (DED), 2) to identify those most appropriate to fulfil the definition of DED and its sub-classifications, 3) to propose the most appropriate order and technique to conduct these tests in a clinical setting, and 4) to provide a differential diagnosis for DED and distinguish conditions where DED is a comorbidity. Prior to diagnosis, it is important to exclude conditions that can mimic DED with the aid of triaging questions. Symptom screening with the DEQ-5 or OSDI confirms that a patient might have DED and triggers the conduct of diagnostic tests of (ideally non-invasive) breakup time, osmolarity and ocular surface staining with fluorescein and lissamine green (observing the cornea, conjunctiva and eyelid margin). Meibomian gland dysfunction, lipid thickness/dynamics and tear volume assessment and their severity allow sub-classification of DED (as predominantly evaporative or aqueous deficient) which informs the management of DED. Videos of these diagnostic and sub-classification techniques are available on the TFOS website. It is envisaged that the identification of the key tests to diagnose and monitor DED and its sub-classifications will inform future epidemiological studies and management clinical trials, improving comparability, and enabling identification of the sub-classification of DED in which different management strategies are most efficacious.

1,152 citations

Journal ArticleDOI
TL;DR: The TFOS DEWS II Pathophysiology Subcommittee reviewed the mechanisms involved in the initiation and perpetuation of dry eye disease, finding the targeting of the terminal duct in meibomian gland disease and the influence of gaze dynamics and the closed eye state on tear stability and ocular surface inflammation to be important.
Abstract: The TFOS DEWS II Pathophysiology Subcommittee reviewed the mechanisms involved in the initiation and perpetuation of dry eye disease. Its central mechanism is evaporative water loss leading to hyperosmolar tissue damage. Research in human disease and in animal models has shown that this, either directly or by inducing inflammation, causes a loss of both epithelial and goblet cells. The consequent decrease in surface wettability leads to early tear film breakup and amplifies hyperosmolarity via a Vicious Circle. Pain in dry eye is caused by tear hyperosmolarity, loss of lubrication, inflammatory mediators and neurosensory factors, while visual symptoms arise from tear and ocular surface irregularity. Increased friction targets damage to the lids and ocular surface, resulting in characteristic punctate epithelial keratitis, superior limbic keratoconjunctivitis, filamentary keratitis, lid parallel conjunctival folds, and lid wiper epitheliopathy. Hybrid dry eye disease, with features of both aqueous deficiency and increased evaporation, is common and efforts should be made to determine the relative contribution of each form to the total picture. To this end, practical methods are needed to measure tear evaporation in the clinic, and similarly, methods are needed to measure osmolarity at the tissue level across the ocular surface, to better determine the severity of dry eye. Areas for future research include the role of genetic mechanisms in non-Sjogren syndrome dry eye, the targeting of the terminal duct in meibomian gland disease and the influence of gaze dynamics and the closed eye state on tear stability and ocular surface inflammation.

994 citations

Journal ArticleDOI
TL;DR: On the basis of these promising results and those of other similar studies, autologous osteochondral mosaicplasty appears to be an alternative for the treatment of small and medium-sized focal chondral and osteochondRAL defects of the weight-bearing surfaces of the knee and other weight- bearing synovial joints.
Abstract: Background: The successful treatment of chondral and osteochondral defects of the weight-bearing surfaces is a challenge for orthopaedic surgeons. Autologous osteochondral transplantation is one method that can be used to create hyaline or hyaline-like repair in the defect area. This paper describes the results after ten years of clinical experience with autologous osteochondral mosaicplasty. Methods: Clinical scores, imaging techniques, arthroscopy, histological examination of biopsy samples, and cartilage stiffness measurements were used to evaluate the clinical outcomes and quality of the transplanted cartilage in 831 patients undergoing mosaicplasty. Results: According to these investigations, good-to-excellent results were achieved in 92% of the patients treated with femoral condylar implantations, 87% of those treated with tibial resurfacing, 79% of those treated with patellar and/or trochlear mosaicplasties, and 94% of those treated with talar procedures. Long-term donor-site disturbances, assessed with use of the Bandi score, showed that patients had 3% morbidity after mosaicplasty. Sixty-nine of eighty-three patients who were followed arthroscopically showed congruent gliding surfaces, histological evidence of the survival of the transplanted hyaline cartilage, and fibrocartilage filling of the donor sites. Complications of the surgery included four deep infections and thirty-six painful postoperative hemarthroses. Conclusions: On the basis of these promising results and those of other similar studies, autologous osteochondral mosaicplasty appears to be an alternative for the treatment of small and medium-sized focal chondral and osteochondral defects of the weight-bearing surfaces of the knee and other weight-bearing synovial joints.

980 citations