scispace - formally typeset
Search or ask a question
Author

Laurie E. Locascio

Bio: Laurie E. Locascio is an academic researcher from National Institute of Standards and Technology. The author has contributed to research in topics: Microchannel & Liposome. The author has an hindex of 38, co-authored 96 publications receiving 7669 citations. Previous affiliations of Laurie E. Locascio include Government of the United States of America.


Papers
More filters
Journal ArticleDOI
11 Feb 2002-Talanta
TL;DR: This article presents a review of polymer-based microfluidic systems including their material properties, fabrication methods, device applications, and finally an analysis of the market that drives their development.

1,150 citations

Journal ArticleDOI
TL;DR: The efficacy of the method is demonstrated by measuring temperature distributions resulting from Joule heating in a variety of microfluidic circuits that are electrokinetically pumped.
Abstract: A technique is described for the measurement of fluid temperatures in microfluidic systems based on temperature-dependent fluorescence. The technique is easy to implement with a standard fluorescence microscope and CCD camera. In addition, the method can be used to measure fluid temperatures with micrometer spatial resolution and millisecond time resolution. The efficacy of the method is demonstrated by measuring temperature distributions resulting from Joule heating in a variety of microfluidic circuits that are electrokinetically pumped. With the equipment used for these measurements, fluid temperatures ranging from room temperature to 90 °C were measured with a precision ranging from 0.03 to 3.5 °Cdependent on the amount of signal averaging done. The spatial and temporal resolutions achieved were 1 μm and 33 ms, respectively.

609 citations

Journal ArticleDOI
TL;DR: Microfluidic devices have been fabricated on poly(methyl methacrylate) substrates by two independent imprinting techniques and fluorescent analtyes were used to demonstrate reproducible electrophoretic injections.
Abstract: Microfluidic devices have been fabricated on poly(methyl methacrylate) substrates by two independent imprinting techniques. First-generation devices were fabricated using a small-diameter wire to create an impression in plastics softened by low-temperature heating. The resulting devices are limited to only simple linear channel designs but are readily produced at low cost. Second-generation devices with more complex microchannel arrangements were fabricated by imprinting the plastic substrates using an inverse three-dimensional image of the device micromachined on a silicon wafer. This micromachined template may be used repeatedly to generate devices reproducibly. Fluorescent analtyes were used to demonstrate reproducible electrophoretic injections. An immunoassay was also performed in an imprinted device as a demonstration of future applications.

571 citations

Journal ArticleDOI
TL;DR: A preformed T-microchannel imprinted in polycarbonate was postmodified with a pulsed UV excimer laser (KrF, 248 nm) to create a series of slanted wells at the junction that leads to a high degree of lateral transport within the channel and rapid mixing of two confluent streams undergoing electroosmotic flow.
Abstract: A preformed T-microchannel imprinted in polycarbonate was postmodified with a pulsed UV excimer laser (KrF, 248 nm) to create a series of slanted wells at the junction. The presence of the wells leads to a high degree of lateral transport within the channel and rapid mixing of two confluent streams undergoing electroosmotic flow. Several mixer designs were fabricated and investigated. All designs were relatively successful at low flow rates (0.06 cm/s, ≥75% mixing), but had varying degrees of success at high flow rates (0.81 cm/s, 45−80% mixing). For example, one design operating at high flow rates was able to split an incoming fluorescent stream into two streams of varying concentrations depending on the number of slanted wells present. The final mixer design was able to overcome stream splitting at high flow rates, and it was shown that the two incoming streams were 80% mixed within 443 μm of the T-junction for a flow rate of 0.81 cm/s. Without the presence of the mixer and at the same high flow rate, a...

522 citations

Journal ArticleDOI
TL;DR: It is demonstrated that by creating a solvent-aqueous interfacial region in a microfluidic format that is homogeneous and controllable on the length scale of a liposome, this work can facilitate the fine control of liposomes size and polydispersity.
Abstract: Traditional liposome preparation methods are based on mixing of bulk phases, leading to inhomogeneous chemical and/or mechanical conditions during formation; hence liposomes are often polydisperse in size and lamellarity. Here we show the formation of liposomes that encapsulate reagents in a continuous two-phase flow microfluidic network with precision control of size from 100 to 300 nm by manipulation of liquid flow rates. We demonstrate that by creating a solvent−aqueous interfacial region in a microfluidic format that is homogeneous and controllable on the length scale of a liposome, we can facilitate the fine control of liposome size and polydispersity.

432 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: A procedure that makes it possible to design and fabricate microfluidic systems in an elastomeric material poly(dimethylsiloxane) (PDMS) in less than 24 h by fabricating a miniaturized capillary electrophoresis system is described.
Abstract: This paper describes a procedure that makes it possible to design and fabricate (including sealing) microfluidic systems in an elastomeric materialpoly(dimethylsiloxane) (PDMS)in less than 24 h. A network of microfluidic channels (with width >20 μm) is designed in a CAD program. This design is converted into a transparency by a high-resolution printer; this transparency is used as a mask in photolithography to create a master in positive relief photoresist. PDMS cast against the master yields a polymeric replica containing a network of channels. The surface of this replica, and that of a flat slab of PDMS, are oxidized in an oxygen plasma. These oxidized surfaces seal tightly and irreversibly when brought into conformal contact. Oxidized PDMS also seals irreversibly to other materials used in microfluidic systems, such as glass, silicon, silicon oxide, and oxidized polystyrene; a number of substrates for devices are, therefore, practical options. Oxidation of the PDMS has the additional advantage that it ...

5,491 citations

Journal ArticleDOI
TL;DR: A review of the physics of small volumes (nanoliters) of fluids is presented, as parametrized by a series of dimensionless numbers expressing the relative importance of various physical phenomena as mentioned in this paper.
Abstract: Microfabricated integrated circuits revolutionized computation by vastly reducing the space, labor, and time required for calculations. Microfluidic systems hold similar promise for the large-scale automation of chemistry and biology, suggesting the possibility of numerous experiments performed rapidly and in parallel, while consuming little reagent. While it is too early to tell whether such a vision will be realized, significant progress has been achieved, and various applications of significant scientific and practical interest have been developed. Here a review of the physics of small volumes (nanoliters) of fluids is presented, as parametrized by a series of dimensionless numbers expressing the relative importance of various physical phenomena. Specifically, this review explores the Reynolds number Re, addressing inertial effects; the Peclet number Pe, which concerns convective and diffusive transport; the capillary number Ca expressing the importance of interfacial tension; the Deborah, Weissenberg, and elasticity numbers De, Wi, and El, describing elastic effects due to deformable microstructural elements like polymers; the Grashof and Rayleigh numbers Gr and Ra, describing density-driven flows; and the Knudsen number, describing the importance of noncontinuum molecular effects. Furthermore, the long-range nature of viscous flows and the small device dimensions inherent in microfluidics mean that the influence of boundaries is typically significant. A variety of strategies have been developed to manipulate fluids by exploiting boundary effects; among these are electrokinetic effects, acoustic streaming, and fluid-structure interactions. The goal is to describe the physics behind the rich variety of fluid phenomena occurring on the nanoliter scale using simple scaling arguments, with the hopes of developing an intuitive sense for this occasionally counterintuitive world.

4,044 citations

Journal ArticleDOI
TL;DR: Fabrication of microfluidic devices in poly(dimethylsiloxane) (PDMS) by soft lithography provides faster, less expensive routes to devices that handle aqueous solutions.
Abstract: Microfluidic devices are finding increasing application as analytical systems, biomedical devices, tools for chemistry and biochemistry, and systems for fundamental research. Conventional methods of fabricating microfluidic devices have centered on etching in glass and silicon. Fabrication of microfluidic devices in poly(dimethylsiloxane) (PDMS) by soft lithography provides faster, less expensive routes than these conventional methods to devices that handle aqueous solutions. These soft-lithographic methods are based on rapid prototyping and replica molding and are more accessible to chemists and biologists working under benchtop conditions than are the microelectronics-derived methods because, in soft lithography, devices do not need to be fabricated in a cleanroom. This paper describes devices fabricated in PDMS for separations, patterning of biological and nonbiological material, and components for integrated systems.

3,344 citations

Journal ArticleDOI
TL;DR: An overview of flows in microdevices with focus on electrokinetics, mixing and dispersion, and multiphase flows is provided, highlighting topics important for the description of the fluid dynamics: driving forces, geometry, and the chemical characteristics of surfaces.
Abstract: Microfluidic devices for manipulating fluids are widespread and finding uses in many scientific and industrial contexts. Their design often requires unusual geometries and the interplay of multiple physical effects such as pressure gradients, electrokinetics, and capillarity. These circumstances lead to interesting variants of well-studied fluid dynamical problems and some new fluid responses. We provide an overview of flows in microdevices with focus on electrokinetics, mixing and dispersion, and multiphase flows. We highlight topics important for the description of the fluid dynamics: driving forces, geometry, and the chemical characteristics of surfaces.

3,307 citations

Journal ArticleDOI
TL;DR: The majority of examples, discussed in this paper, deal with pH-responsive drug delivery system, and Thermo-responsive polymer is also covered to a large extent, as well as double-responsive system.

2,746 citations