scispace - formally typeset
Search or ask a question
Author

Lev Gregorian

Bio: Lev Gregorian is an academic researcher from Advanced Technology Center. The author has an hindex of 1, co-authored 1 publications receiving 63 citations.

Papers
More filters
Journal ArticleDOI
TL;DR: The three CT components with the greatest impact on image quality are the X-ray source, detection system and reconstruction algorithms, and this paper focuses on the first two.
Abstract: The three CT components with the greatest impact on image quality are the X-ray source, detection system and reconstruction algorithms. In this paper, we focus on the first two. We describe the state-of-the-art of CT detection systems, their calibrations, software corrections and common performance metrics. The components of CT detection systems, such as scintillator materials, photodiodes, data acquisition electronics and anti-scatter grids, are discussed. Their impact on CT image quality, their most important characteristics, as well as emerging future technology trends for each, are reviewed. The use of detection for multi-energy CT imaging is described. An overview of current CT X-ray sources, their evolution to support major trends in CT imaging and future trends is provided.

91 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: PCD technology and its use for in vivo high-spatial-resolution multienergy CT imaging is discussed, and examples with phantom, animal, and patient studies are provided.
Abstract: Photon-counting detector (PCD) CT is an emerging technology that has shown tremendous progress in the last decade. Various types of PCD CT systems have been developed to investigate the benefits of this technology, which include reduced electronic noise, increased contrast-to-noise ratio with iodinated contrast material and radiation dose efficiency, reduced beam-hardening and metal artifacts, extremely high spatial resolution (33 line pairs per centimeter), simultaneous multienergy data acquisition, and the ability to image with and differentiate among multiple CT contrast agents. PCD technology is described and compared with conventional CT detector technology. With the use of a whole-body research PCD CT system as an example, PCD technology and its use for in vivo high-spatial-resolution multienergy CT imaging is discussed. The potential clinical applications, diagnostic benefits, and challenges associated with this technology are then discussed, and examples with phantom, animal, and patient studies are provided. ©RSNA, 2019.

234 citations

Journal ArticleDOI
TL;DR: Comparing DECT with future MECT, the authors found noticeable material image quality improvements for an ideal photon counting detector; however, a realistic detector model with multiple energy bins predicts a performance on the level of dual source DECT at 100 kV/Sn 140 kV.
Abstract: Purpose: To study the performance of different dual energy computed tomography (DECT) techniques, which are available today, and future multi energy CT (MECT) employing novel photon counting detectors in an image-based material decomposition task. Methods: The material decomposition performance of different energy-resolved CT acquisition techniques is assessed and compared in a simulation study of virtual non-contrast imaging and iodine quantification. The material-specific images are obtained via a statistically optimal image-based material decomposition. A projection-based maximum likelihood approach was used for comparison with the authors’ image-based method. The different dedicated dual energy CT techniques are simulated employing realistic noise models and x-ray spectra. The authors compare dual source DECT with fast kV switching DECT and the dual layer sandwich detector DECT approach. Subsequent scanning and a subtraction method are studied as well. Further, the authors benchmark future MECT with novel photon counting detectors in a dedicated DECT application against the performance of today’s DECT using a realistic model. Additionally, possible dual source concepts employing photon counting detectors are studied. Results: The DECT comparison study shows that dual source DECT has the best performance, followed by the fast kV switching technique and the sandwich detector approach. Comparing DECT with future MECT, the authors found noticeable material image quality improvements for an ideal photon counting detector; however, a realistic detector model with multiple energy bins predicts a performance on the level of dual source DECT at 100 kV/Sn 140 kV. Employing photon counting detectors in dual source concepts can improve the performance again above the level of a single realistic photon counting detector and also above the level of dual source DECT. Conclusions: Substantial differences in the performance of today’s DECT approaches were found for the application of virtual non-contrast and iodine imaging. Future MECT with realistic photon counting detectors currently can only perform comparably to dual source DECT at 100 kV/Sn 140 kV. Dual source concepts with photon counting detectors could be a solution to this problem, promising a better performance.

184 citations

Journal ArticleDOI
TL;DR: Technical advancements of scanner hardware and image reconstruction techniques are reviewed and discussed in their clinical context and have led to a steady increase of CT examinations in all age groups for a number of reasons.
Abstract: The advent of computed tomography (CT) has revolutionized radiology. Starting as head-only scanners, modern CT systems are now capable of performing whole-body examinations within a couple of seconds in isotropic resolution. Technical advancements of scanner hardware and image reconstruction techniques are reviewed and discussed in their clinical context. These improvements have led to a steady increase of CT examinations in all age groups for a number of reasons. On the one hand, it is very easy today to obtain whole-body data for oncologic staging and follow-up or for trauma imaging. On the other hand, new examinations such as cardiac imaging, virtual colonoscopy, gout imaging, and whole-organ perfusion imaging have widened the application profile of CT. The increasing awareness of risks associated with radiation exposure triggered the development of a variety of dose reduction techniques. Effective dose values below 1 mSv, less than the annual natural background radiation (3.1 mSv/year on average in the United States), are now routinely possible for a number of dedicated examinations, even for coronary CT angiography.

133 citations

Journal ArticleDOI
TL;DR: An overview of data processing, reconstruction methods and metrics of imaging performance; outline clinical applications; and discuss potential future developments in the field of photon-counting CT are given.
Abstract: The introduction of photon-counting detectors is expected to be the next major breakthrough in clinical x-ray computed tomography (CT). During the last decade, there has been considerable research activity in the field of photon-counting CT, in terms of both hardware development and theoretical understanding of the factors affecting image quality. In this article, we review the recent progress in this field with the intent of highlighting the relationship between detector design considerations and the resulting image quality. We discuss detector design choices such as converter material, pixel size, and readout electronics design, and then elucidate their impact on detector performance in terms of dose efficiency, spatial resolution, and energy resolution. Furthermore, we give an overview of data processing, reconstruction methods and metrics of imaging performance; outline clinical applications; and discuss potential future developments.

100 citations

Journal ArticleDOI
TL;DR: Dual‐layer detector based CT offers high quantitative accuracy of spectral images over the complete field‐of‐view without any compromise in radiation dose or diagnostic image quality.
Abstract: The performance of a recently introduced spectral computed tomography system based on a dual-layer detector has been investigated. A semi-anthropomorphic abdomen phantom for CT performance evaluation was imaged on the dual-layer spectral CT at different radiation exposure levels (CTDIvol of 10 mGy, 20 mGy and 30 mGy). The phantom was equipped with specific low-contrast and tissue-equivalent inserts including water-, adipose-, muscle-, liver-, bone-like materials and a variation in iodine concentrations. Additionally, the phantom size was varied using different extension rings to simulate different patient sizes. Contrast-to-noise (CNR) ratio over the range of available virtual mono-energetic images (VMI) and the quantitative accuracy of VMI Hounsfield Units (HU), effective-Z maps and iodine concentrations have been evaluated. Central and peripheral locations in the field-of-view have been examined. For all evaluated imaging tasks the results are within the calculated theoretical range of the tissue-equivalent inserts. Especially at low energies, the CNR in VMIs could be boosted by up to 330% with respect to conventional images using iDose/spectral reconstructions at level 0. The mean bias found in effective-Z maps and iodine concentrations averaged over all exposure levels and phantom sizes was 1.9% (eff. Z) and 3.4% (iodine). Only small variations were observed with increasing phantom size (+3%) while the bias was nearly independent of the exposure level (±0.2%). Therefore, dual-layer detector based CT offers high quantitative accuracy of spectral images over the complete field-of-view without any compromise in radiation dose or diagnostic image quality.

62 citations