scispace - formally typeset
Search or ask a question

Showing papers by "Lidia Morawska published in 2013"


Journal ArticleDOI
TL;DR: In this article, the authors reviewed existing literature to identify state-of-the-art experimental techniques used for personal exposure assessment; compare exposure levels reported for domestic/school settings in different countries, assess the contribution of outdoor background vs indoor sources to personal exposure; and examine scientific understanding of the risks posed by personal exposure to indoor aerosols.
Abstract: Motivated by growing considerations of the scale, severity, and risks associated with human exposure to indoor particulate matter, this work reviewed existing literature to: (i) identify state-of-the-art experimental techniques used for personal exposure assessment; (ii) compare exposure levels reported for domestic/school settings in different countries (excluding exposure to environmental tobacco smoke and particulate matter from biomass cooking in developing countries); (iii) assess the contribution of outdoor background vs indoor sources to personal exposure; and (iv) examine scientific understanding of the risks posed by personal exposure to indoor aerosols. Limited studies assessing integrated daily residential exposure to just one particle size fraction, ultrafine particles, show that the contribution of indoor sources ranged from 19% to 76%. This indicates a strong dependence on resident activities, source events and site specificity, and highlights the importance of indoor sources for total personal exposure. Further, it was assessed that 10-30% of the total burden of disease from particulate matter exposure was due to indoor-generated particles, signifying that indoor environments are likely to be a dominant environmental factor affecting human health. However, due to challenges associated with conducting epidemiological assessments, the role of indoor-generated particles has not been fully acknowledged, and improved exposure/risk assessment methods are still needed, together with a serious focus on exposure control.

364 citations


Journal ArticleDOI
TL;DR: In this paper, the authors performed continuous exposure monitoring to estimate alveolar and tracheobronchial dose, measured as deposited surface area, for 103 children and evaluated the long-term effects of exposure to airborne particles through spirometry, skin prick tests and measurement of exhaled nitric oxide (eNO).

130 citations


Journal ArticleDOI
TL;DR: In this paper, the authors reviewed and summarised physical factors of the indoor environment reported to affect human health and wellbeing in HCFs and provided a practical resource for those responsible for the design and operate the facilities as well as researchers investigating these factors.
Abstract: Understanding the physical characteristics of the indoor environment that affect human health and wellbeing is the key requirement underpinning the beneficial design of a healthcare facility (HCF) We reviewed and summarised physical factors of the indoor environment reported to affect human health and wellbeing in HCFs Research materials included articles identified in a Pubmed search, guidelines, books, reports and monographs, as well as the bibliographies of review articles in the area studied Of these, 209 publications were selected for this review According to the literature, there is evidence that the following physical factors of the indoor environment affect the health and wellbeing of human beings in an HCF: safety, ventilation and HVAC systems, thermal environment, acoustic environment, interior layout and room type, windows (including daylight and views), nature and gardens, lighting, colour, floor covering, furniture and its placement, ergonomics, wayfinding, artworks and music Some of these, in themselves, directly promote or hinder health and wellbeing, but the physical factors may also have numerous indirect impacts by influencing the behaviour, actions, and interactions of patients, their families and the staff members The findings of this research enable a good understanding of the different physical factors of the indoor environment on health and wellbeing and provide a practical resource for those responsible for the design and operate the facilities as well as researchers investigating these factors However, more studies are needed in order to inform the design of optimally beneficial indoor environments in HCFs for all user groups

109 citations


Journal ArticleDOI
TL;DR: In this paper, an exposure assessment of children in relation to two different aerosol species: ultrafine particles (UFPs) and black carbon (BC) was performed on 103 children aged 8-11 years using hand-held particle counters and aethalometers.

106 citations


Journal ArticleDOI
TL;DR: In this paper, the authors quantified the efficiency of deep bag and electrostatic filters, and assessed the influence of ventilation systems using these filters on indoor fine and ultrafine particle concentrations in commercial office buildings.

98 citations


01 Jan 2013
TL;DR: In this paper, the authors discuss the challenges faced by Indian megacities in their quest for sustainable growth, without compromising the air quality and urban way of life, and discuss the solutions to these challenges.
Abstract: Deterioration of air quality in Indian megacities (Delhi, Mumbai or Kolkata) is much more significant than that observed in the megacities of developed countries. Densely packed high-rise buildings restrict the self-cleaning capabilities of Indian megacities. Also, the ever growing number of on-road vehicles, resuspension of the dust, and anthropogenic activities exacerbate the levels of ambient air pollution, which is in turn breathed by urban dwellers. Pollution levels exceeding the standards on a regular basis often result in a notable increase in morbidity and mortality. This article discusses the challenges faced by Indian megacities in their quest for sustainable growth, without compromising the air quality and urban way of life.

87 citations


Journal ArticleDOI
TL;DR: In this article, measurements in terms of particle number concentration, particle size distribution and black carbon (BC) concentrations were performed in three school buildings in Cassino (Italy) and its suburbs, outside and inside of the classrooms during normal occupancy and use.

84 citations


Journal ArticleDOI
TL;DR: In this paper, the authors discuss the challenges faced by Indian megacities in their quest for sustainable growth, without compromising the air quality and urban way of life, and discuss the solutions to these challenges.

76 citations


Journal ArticleDOI
TL;DR: In this article, the potential to lower exposure to ultrafine particles during bicycle commuting by reducing proximity to motorised traffic was investigated with real-time air pollution and intermittent acute inflammatory measurements in healthy individuals using their typical higher proximity, and an alternative lower proximity, bicycle commute route.
Abstract: Bicycle commuting in an urban environment of high air pollution is known to be a potential health risk, especially for susceptible individuals. While risk management strategies aimed to reduce exposure to motorised traffic emissions have been suggested, only limited studies have assessed the utility of such strategies in real-world circumstances. The potential to lower exposure to ultrafine particles (UFP; < 0.1 μm) during bicycle commuting by reducing proximity to motorised traffic was investigated with real-time air pollution and intermittent acute inflammatory measurements in healthy individuals using their typical higher proximity, and an alternative lower proximity, bicycle commute route. Thirty-five healthy adults (mean ± SD: age = 39 ± 11 yr; 29% female) completed two return trips, one each in the condition of their typical route (HIGH) and a pre-determined alternative route of lower proximity to motorised traffic (LOW); proximity being determined by the proportion of on-road cycle paths. Particle number concentration (PNC) and diameter (PD) were monitored in-commute in real-time. Acute inflammatory indices of respiratory symptoms (as a scalar of frequency from very low to very high / 1 to 5), lung function and spontaneous sputum (for inflammatory cell analyses) were collected immediately pre-commute, and immediately and three hours post-commute. In the condition of LOW, compared to in the condition of HIGH, there was a significant decrease in mean PNC (1.91 x e4 ± 0.93 × e4 ppcc vs. 2.95 × e4 ± 1.50 × e4 ppcc; p ≤ 0.001), and the mean frequency of in-commute offensive odour detection (2.1 vs. 2.8; p = 0.019), dust and soot observation (1.7 vs. 2.3; p = 0.038) and nasopharyngeal irritation (1.5 vs. 1.9; p = 0.007). There were no significant differences between LOW and HIGH in the commute distance and duration (12.8 ± 7.1 vs. 12.0 ± 6.9 km and 44 ± 17 vs. 42 ± 17 min, respectively), or other indices of acute airway inflammation. Exposure to PNC and offensive odour, and nasopharyngeal irritation, can be significantly lowered when utilising a route of lower proximity to motorised traffic whilst bicycle commuting, without significantly affecting commute distance or duration. This may bring health benefits for both healthy and susceptible individuals.

44 citations


Journal ArticleDOI
TL;DR: In this paper, the implications of key indoor physical design parameters, in relation to their potential impact on human health and wellbeing, were reviewed and discussed within the context of relevant guidelines and standards for the design of healthcare facilities.
Abstract: As a result of growing evidence regarding the effects of environmental characteristics on the health and wellbeing of people in healthcare facilities (HCFs), more emphasis is being placed on, and more attention being paid to, the consequences of design choices in HCFs. Therefore, we have critically reviewed the implications of key indoor physical design parameters, in relation to their potential impact on human health and wellbeing. In addition, we discussed these findings within the context of the relevant guidelines and standards for the design of HCFs. A total of 810 abstracts that met the inclusion criteria were identified through a PubMed search, and these covered journal articles, guidelines, books, reports and monographs in the studied area. Out of these, 230 full publications were selected for this review. According to the literature, the most beneficial design elements were: single-bed patient rooms, safe and easily cleaned surface materials, sound-absorbing ceiling tiles, adequate and sufficient...

42 citations


Journal ArticleDOI
TL;DR: In this article, the authors determined the spatial variation of particle number concentration (PNC) within microscale school environments, in order to assess the importance of the number of monitoring sites on exposure estimation.
Abstract: It has not yet been established whether the spatial variation of particle number concentration (PNC) within a microscale environment can have an effect on exposure estimation results. In general, the degree of spatial variation within microscale environments remains unclear, since previous studies have only focused on spatial variation within macroscale environments. The aims of this study were to determine the spatial variation of PNC within microscale school environments, in order to assess the importance of the number of monitoring sites on exposure estimation. Furthermore, this paper aims to identify which parameters have the largest influence on spatial variation, as well as the relationship between those parameters and spatial variation. Air quality measurements were conducted for two consecutive weeks at each of the 25 schools across Brisbane, Australia. PNC was measured at three sites within the grounds of each school, along with the measurement of meteorological and several other air quality parameters. Traffic density was recorded for the busiest road adjacent to the school. Spatial variation at each school was quantified using coefficient of variation (CV). The portion of CV associated with instrument uncertainty was found to be 0.3 and therefore, CV was corrected so that only non-instrument uncertainty was analysed in the data. The median corrected CV (CVc) ranged from 0 to 0.35 across the schools, with 12 schools found to exhibit spatial variation. The study determined the number of required monitoring sites at schools with spatial variability and tested the deviation in exposure estimation arising from using only a single site. Nine schools required two measurement sites and three schools required three sites. Overall, the deviation in exposure estimation from using only one monitoring site was as much as one order of magnitude. The study also tested the association of spatial variation with wind speed/direction and traffic density, using partial correlation coefficients to identify sources of variation and non-parametric function estimation to quantify the level of variability. Traffic density and road to school wind direction were found to have a positive effect on CVc, and therefore, also on spatial variation. Wind speed was found to have a decreasing effect on spatial variation when it exceeded a threshold of 1.5 (m/s), while it had no effect below this threshold. Traffic density had a positive effect on spatial variation and its effect increased until it reached a density of 70 vehicles per five minutes, at which point its effect plateaued and did not increase further as a result of increasing traffic density.

01 Apr 2013
TL;DR: The results of this study provide important scientific information on the toxicity of aircraft exhaust and their impact on local air quality.
Abstract: In order to provide realistic data for air pollution inventories and source apportionment at airports, the morphology and composition of ultrafine particles (UFP) in aircraft engine exhaust were measured and characterized. For this purpose, two independent measurement techniques were employed to collect emissions during normal takeoff and landing operations at Brisbane Airport, Australia. PM1 emissions in the airfield were collected on filters and analyzed using the particle-induced X-ray emission (PIXE) technique. Morphological and compositional analyses of individual ultrafine particles in aircraft plumes were performed on silicon nitride membrane grids using transmission electron microscopy (TEM) combined with energy-dispersive X-ray microanalysis (EDX). TEM results showed that the deposited particles were in the range of 5 to 100 nm in diameter, had semisolid spherical shapes and were dominant in the nucleation mode (18 – 20 nm). The EDX analysis showed the main elements in the nucleation particles were C, O, S and Cl. The PIXE analysis of the airfield samples was generally in agreement with the EDX in detecting S, Cl, K, Fe and Si in the particles. The results of this study provide important scientific information on the toxicity of aircraft exhaust and their impact on local air quality.

Journal ArticleDOI
TL;DR: In this article, the morphology and composition of ultrafine particles (UFP) in aircraft engine exhaust were measured and characterized using transmission electron microscopy (TEM) combined with energy-dispersive X-ray microanalysis (EDX).
Abstract: In order to provide realistic data for air pollution inventories and source apportionment at airports, the morphology and composition of ultrafine particles (UFP) in aircraft engine exhaust were measured and characterized. For this purpose, two independent measurement techniques were employed to collect emissions during normal takeoff and landing operations at Brisbane Airport, Australia. PM1 emissions in the airfield were collected on filters and analyzed using the particle-induced X-ray emission (PIXE) technique. Morphological and compositional analyses of individual ultrafine particles in aircraft plumes were performed on silicon nitride membrane grids using transmission electron microscopy (TEM) combined with energy-dispersive X-ray microanalysis (EDX). TEM results showed that the deposited particles were in the range of 5 to 100 nm in diameter, had semisolid spherical shapes and were dominant in the nucleation mode (18 – 20 nm). The EDX analysis showed the main elements in the nucleation particles were C, O, S and Cl. The PIXE analysis of the airfield samples was generally in agreement with the EDX in detecting S, Cl, K, Fe and Si in the particles. The results of this study provide important scientific information on the toxicity of aircraft exhaust and their impact on local air quality.

Journal ArticleDOI
TL;DR: In this article, an interlaboratory comparison on size characterization of SiO2 airborne nanoparticles using on-line and off-line measurement techniques is discussed, and the results of the main size distribution parameters (mean and mode diameters), obtained from several laboratories, were compared based on metrological approaches.
Abstract: Results of an interlaboratory comparison on size characterization of SiO2 airborne nanoparticles using on-line and off-line measurement techniques are discussed. This study was performed in the framework of Technical Working Area (TWA) 34—“Properties of Nanoparticle Populations” of the Versailles Project on Advanced Materials and Standards (VAMAS) in the project no. 3 “Techniques for characterizing size distribution of airborne nanoparticles”. Two types of nano-aerosols, consisting of (1) one population of nanoparticles with a mean diameter between 30.3 and 39.0 nm and (2) two populations of non-agglomerated nanoparticles with mean diameters between, respectively, 36.2–46.6 nm and 80.2–89.8 nm, were generated for characterization measurements. Scanning mobility particle size spectrometers (SMPS) were used for on-line measurements of size distributions of the produced nano-aerosols. Transmission electron microscopy, scanning electron microscopy, and atomic force microscopy were used as off-line measurement techniques for nanoparticles characterization. Samples were deposited on appropriate supports such as grids, filters, and mica plates by electrostatic precipitation and a filtration technique using SMPS controlled generation upstream. The results of the main size distribution parameters (mean and mode diameters), obtained from several laboratories, were compared based on metrological approaches including metrological traceability, calibration, and evaluation of the measurement uncertainty. Internationally harmonized measurement procedures for airborne SiO2 nanoparticles characterization are proposed.

Journal ArticleDOI
TL;DR: Emission of bacteria and molds (Penicillium/Aspergillus) can reach values as high as 1E5 cell equivalents/min and that those emissions are not related to each other, and diversity analyses showed that most bacteria are from human sources, in keeping with other recent results.
Abstract: Vacuum cleaners can release large concentrations of particles, both in their exhaust air and from resuspension of settled dust. However, the size, variability, and microbial diversity of these emissions are unknown, despite evidence to suggest they may contribute to allergic responses and infection transmission indoors. This study aimed to evaluate bioaerosol emission from various vacuum cleaners. We sampled the air in an experimental flow tunnel where vacuum cleaners were run, and their airborne emissions were sampled with closed-face cassettes. Dust samples were also collected from the dust bag. Total bacteria, total archaea, Penicillium/Aspergillus, and total Clostridium cluster 1 were quantified with specific quantitative PCR protocols, and emission rates were calculated. Clostridium botulinum and antibiotic resistance genes were detected in each sample using endpoint PCR. Bacterial diversity was also analyzed using denaturing gradient gel electrophoresis (DGGE), image analysis, and band sequencing. We demonstrated that emission of bacteria and molds (Penicillium/Aspergillus) can reach values as high as 1E5 cell equivalents/min and that those emissions are not related to each other. The bag dust bacterial and mold content was also consistent across the vacuums we assessed, reaching up to 1E7 bacterial or mold cell equivalents/g. Antibiotic resistance genes were detected in several samples. No archaea or C. botulinum was detected in any air samples. Diversity analyses showed that most bacteria are from human sources, in keeping with other recent results. These results highlight the potential capability of vacuum cleaners to disseminate appreciable quantities of molds and human-associated bacteria indoors and their role as a source of exposure to bioaerosols.

Journal ArticleDOI
TL;DR: No relationship between endotoxin concentration and load is indicated, which points to the necessity for measuring endotoxin levels in both the air and settled dust, and temperature increases were associated with lower concentrations in indoor air and higher loads in floor dust.
Abstract: Endotoxins can significantly affect the air quality in school environments. However, there is currently no reliable method for the measurement of endotoxins, and there is a lack of reference values for endotoxin concentrations to aid in the interpretation of measurement results in school settings. We benchmarked the "baseline" range of endotoxin concentration in indoor air, together with endotoxin load in floor dust, and evaluated the correlation between endotoxin levels in indoor air and settled dust, as well as the effects of temperature and humidity on these levels in subtropical school settings. Bayesian hierarchical modeling indicated that the concentration in indoor air and the load in floor dust were generally (<95th percentile) <13 EU/m(3) and <24,570 EU/m(2), respectively. Exceeding these levels would indicate abnormal sources of endotoxins in the school environment and the need for further investigation. Metaregression indicated no relationship between endotoxin concentration and load, which points to the necessity for measuring endotoxin levels in both the air and settled dust. Temperature increases were associated with lower concentrations in indoor air and higher loads in floor dust. Higher levels of humidity may be associated with lower airborne endotoxin concentrations.

01 Aug 2013
TL;DR: In this article, the authors evaluated the correlation between endotoxin levels in indoor air and settled dust, as well as the effects of temperature and humidity on these levels in subtropical school settings.
Abstract: Endotoxins can significantly affect the air quality in school environments. However, there is currently no reliable method for the measurement of endotoxins and there is a lack of reference values for endotoxin concentrations to aid in the interpretation of measurement results in school settings. We benchmarked the “baseline” range of endotoxin concentration in indoor air, together with endotoxin load in floor dust, and evaluated the correlation between endotoxin levels in indoor air and settled dust, as well as the effects of temperature and humidity on these levels in subtropical school settings. Bayesian hierarchical modeling indicated that the concentration in indoor air and the load in floor dust were generally (<95th percentile) < 13 EU/m3 and < 24,570 EU/m2, respectively. Exceeding these levels would indicate abnormal sources of endotoxins in the school environment, and the need for further investigation. Metaregression indicated no relationship between endotoxin concentration and load, which points to the necessity for measuring endotoxin levels in both the air and settled dust. Temperature increases were associated with lower concentrations in indoor air and higher loads in floor dust. Higher levels of humidity may be associated with lower airborne endotoxin concentrations.

Journal ArticleDOI
TL;DR: In this article, the authors argue that the key questions are how energy consumption is distributed between different building services, and how the resulting pollution affects indoor air quality, and they argue that such studies could be instrumental in providing sustainable solutions to maintain the trade-off between the energy efficiency of buildings and acceptable levels of air pollution for healthy living.
Abstract: Since the first oil crisis in 1974, economic reasons placed energy saving among the top priorities in most industrialised countries. In the decades that followed, another, equally strong driver for energy saving emerged: climate change caused by anthropogenic emissions, a large fraction of which result from energy generation. Intrinsically linked to energy consumption and its related emissions is another problem: indoor air quality. City dwellers in industrialised nations spend over 90% of their time indoors and exposure to indoor pollutants contributes to ~2.6% of global burden of disease and nearly 2 million premature deaths per year1. Changing climate conditions, together with human expectations of comfortable thermal conditions, elevates building energy requirements for heating, cooling, lighting and the use of other electrical equipment. We believe that these changes elicit a need to understand the nexus between energy consumption and its consequent impact on indoor air quality in urban buildings. In our opinion the key questions are how energy consumption is distributed between different building services, and how the resulting pollution affects indoor air quality. The energy-pollution nexus has clearly been identified in qualitative terms; however the quantification of such a nexus to derive emissions or concentrations per unit energy consumption is still weak, inconclusive and requires forward thinking. Of course, various aspects of energy consumption and indoor air quality have been studied in detail separately, but in-depth, integrated studies of the energy-pollution nexus are hard to come by. We argue that such studies could be instrumental in providing sustainable solutions to maintain the trade-off between the energy efficiency of buildings and acceptable levels of air pollution for healthy living.

Journal ArticleDOI
TL;DR: In this paper, a technique for analysing exhaust emission plumes from unmodified locomotives under real world conditions is described and applied to the task of characterizing plumes of railway trains servicing an Australian shipping port.

Journal ArticleDOI
TL;DR: In this paper, an intensive campaign was undertaken where particles and small ions of both signs were monitored over two week periods at each of three sites A, B and C that were affected to varying degrees by vehicle emissions.

Journal ArticleDOI
TL;DR: In this article, the surface area of inhaled particles deposited in the alveolar region, as reported by the TSI nanoparticle surface area monitor (NSAM), was compared with the corresponding value estimated by a TSI scanning mobility particle sizer (SMPS) for a range of environmentally relevant aerosols, including petrol emissions, ETS, laser printer emissions, cooking emissions and ambient aerosols.

Journal ArticleDOI
TL;DR: In this article, the sources of air pollution were identified by applying two mathematical models to data consisting of particle size distribution and chemical composition data, using positive matrix factorization (PMF) and principal component analysis-absolute principal component scores (PCA-APCS) compared with information from gaseous chemical composition analysis.
Abstract: Environmental context Identifying the sources responsible for air pollution is crucial for reducing the effect of the pollutants on human health. The sources of the pollutants were found here by applying two mathematical models to data consisting of particle size distribution and chemical composition data. The identified sources could be used as the basis for controlling or reducing emissions of air pollution into the atmosphere. Abstract Particulate matter is common in our environment and has been linked to human health problems particularly in the ultrafine size range. In this investigation, the sources of particles measured at two sites in Brisbane, Australia, were identified by analysing particle number size distribution data, chemical species concentrations and meteorological data with two source apportionment models. The source apportionment results obtained by positive matrix factorisation (PMF) and principal component analysis–absolute principal component scores (PCA–APCS) were compared with information from the gaseous chemical composition analysis. Although PCA–APCS resolved more sources, the results of the PMF analysis appear to be more reliable. Six common sources were identified by both methods and these include: traffic 1, traffic 2, local traffic, biomass burning and two unassigned factors. Thus motor vehicle related activities had the greatest effect on the data with the average contribution from nearly all sources to the measured concentrations being higher during peak traffic hours and weekdays. Further analyses incorporated the meteorological measurements into the PMF results to determine the direction of the sources relative to the measurement sites, and this indicated that traffic on the nearby road and intersection was responsible for most of the factors. The described methodology that utilised a combination of three types of data related to particulate matter to determine the sources and combination of two receptor models could assist future development of particle emission control and reduction strategies.

Journal ArticleDOI
TL;DR: In this article, a method for investigating ship emissions, the plume capture and analysis system (PCAS), and its application in measuring airborne pollutant emission factors (EFs) and particle size distributions was presented.

Journal ArticleDOI
TL;DR: In this article, the overall aim of the study was to characterize airborne particles from selected nanotechnology processes and to utilize the data to develop and test quantitative particle concentration-based criteria that can be used to trigger an assessment of particle emission controls.
Abstract: The overall aim of our research was to characterize airborne particles from selected nanotechnology processes and to utilize the data to develop and test quantitative particle concentration-based criteria that can be used to trigger an assessment of particle emission controls. We investigated particle number concentration (PNC), particle mass (PM) concentration, count median diameter (CMD), alveolar deposited surface area, elemental composition, and morphology from sampling of aerosols arising from six nanotechnology processes. These included fibrous and non-fibrous particles, including carbon nanotubes (CNTs). We adopted standard occupational hygiene principles in relation to controlling peak emission and exposures, as outlined by both Safe Work Australia, (1) and the American Conference of Governmental Industrial Hygienists (ACGIH®). (2) The results from the study were used to analyses peak and 30-minute averaged particle number and mass concentration values measured during the operation of the nanotech...

Journal ArticleDOI
TL;DR: In this article, an Aerodyne compact time-of-flight aerosol mass spectrometer (TOF-AMS) was deployed at five urban schools in Brisbane, Australia to quantify the concentration of organic aerosol (OA) and in particular, vehicle emissions that children are exposed to during school hours.

Journal Article
TL;DR: In this article, the authors discuss the challenges faced by Indian megacities in their quest for sustainable growth, without compromising the air quality and urban way of life, and discuss the solutions to these challenges.

01 Jan 2013
TL;DR: In this article, a method for investigating ship emissions, the plume capture and analysis system (PCAS), and its application in measuring airborne pollutant emission factors (EFs) and particle size distributions was presented.
Abstract: This paper presents a method for investigating ship emissions, the plume capture and analysis system (PCAS), and its application in measuring airborne pollutant emission factors (EFs) and particle size distributions. The current investigation was conducted in situ, aboard two dredgers (Amity: a cutter suction dredger and Brisbane: a hopper suction dredger) but the PCAS is also capable of performing such measurements remotely at a distant point within the plume. EFs were measured relative to the fuel consumption using the fuel combustion derived plume CO2. All plume measurements were corrected by subtracting background concentrations sampled regularly from upwind of the stacks. Each measurement typically took 6 minutes to complete and during one day, 40 to 50 measurements were possible. The relationship between the EFs and plume sample dilution was examined to determine the plume dilution range over which the technique could deliver consistent results when measuring EFs for particle number (PN), NOx, SO2, and PM2.5 within a targeted dilution factor range of 50-1000 suitable for remote sampling. The EFs for NOx, SO2, and PM2.5 were found to be independent of dilution, for dilution factors within that range. The EF measurement for PN was corrected for coagulation losses by applying a time dependant particle loss correction to the particle number concentration data. For the Amity, the EF ranges were PN: 2.2 - 9.6 × 1015 (kg-fuel)-1; NOx: 35-72 g(NO2).(kg-fuel)-1, SO2 0.6 - 1.1 g(SO2).(kg-fuel)-1and PM2.5: 0.7 – 6.1 g(PM2.5).(kg-fuel)-1. For the Brisbane they were PN: 1.0 – 1.5 x 1016 (kg-fuel)-1, NOx: 3.4 – 8.0 g(NO2).(kg-fuel)-1, SO2: 1.3 – 1.7 g(SO2).(kg-fuel)-1 and PM2.5: 1.2 – 5.6 g(PM2.5).(kg-fuel)-1. The results are discussed in terms of the operating conditions of the vessels’ engines. Particle number emission factors as a function of size as well as the count median diameter (CMD), and geometric standard deviation of the size distributions are provided. The size distributions were found to be consistently uni-modal in the range below 500 nm, and this mode was within the accumulation mode range for both vessels. The representative CMDs for the various activities performed by the dredgers ranged from 94-131 nm in the case of the Amity, and 58-80 nm for the Brisbane. A strong inverse relationship between CMD and EF(PN) was observed.

21 May 2013
TL;DR: Variation is a child's activity over time appeared to have a strong impact on respiratory outcomes, which indicates that personal monitoring is vital for assessing the expected health effects of exposure to particles.
Abstract: Air pollution is a widespread health problem associated with respiratory symptoms. Continuous exposure monitoring was performed to estimate alveolar and tracheobronchial dose, measured as deposited surface area, for 103 children and to evaluate the long-term effects of exposure to airborne particles through spirometry, skin prick tests and measurement of exhaled nitric oxide (eNO). The mean daily alveolar deposited surface area dose received by children was 1.35×103 mm2. The lowest and highest particle number concentrations were found during sleeping and eating time. A significant negative association was found between changes in pulmonary function tests and individual dose estimates. Significant differences were found for asthmatics, children with allergic rhinitis and sensitive to allergens compared to healthy subjects for eNO. Variation is a child’s activity over time appeared to have a strong impact on respiratory outcomes, which indicates that personal monitoring is vital for assessing the expected health effects of exposure to particles.

Journal ArticleDOI
TL;DR: Overall, this procedure provides accurate representation of the mass spectra of ambient organic aerosols and could facilitate rapid data acquisition at multiple sites where AMS could not be deployed for logistical reasons.

Journal Article
TL;DR: In this article, the authors developed new guidelines focused on household fuel combustion, covering cooking, heating and lighting, and although global, the key focus is low and middle income countries reflecting the distribution of disease burden.
Abstract: Household air pollution (HAP), arising mainly from the combustion of solid and other polluting fuels, is responsible for a very substantial public health burden, most recently estimated as causing 3.5 million premature deaths in 2010. These patterns of household fuel use have also important negative impacts on safety, prospects for poverty reduction and the environment, including climate change. Building on previous air quality guidelines, the WHO is developing new guidelines focused on household fuel combustion, covering cooking, heating and lighting, and although global, the key focus is low and middle income countries reflecting the distribution of disease burden. As discussed in this paper, currently in development, the guidelines will include reviews of a wide range of evidence including fuel use in homes, emissions from stoves and lighting, household air pollution and exposure levels experienced by populations, health risks, impacts of interventions on HAP and exposure, and also key factors influencing sustainable and equitable adoption of improved stoves and cleaner fuels. GRADE, the standard method used for guidelines evidence review may not be well suited to the variety and nature of evidence required for this project, and a modified approach is being developed and tested. Work on the guidelines is being carried out in close collaboration with the UN Foundation Global Alliance on Clean cookstoves, allowing alignment with specific tools including recently developed international voluntary standards for stoves, and the development of country action plans. Following publication, WHO plans to work closely with a number of countries to learn from implementation efforts, in order to further strengthen support and guidance. A case study on the situation and policy actions to date in Bhutan provide an illustration of the challenges and opportunities involved, and the timely importance of the new guidelines and associated research, evaluation and policy development agendas.