scispace - formally typeset
Search or ask a question
Author

Lisa Veltri

Bio: Lisa Veltri is an academic researcher from University of Pittsburgh. The author has contributed to research in topics: Restenosis & Stent. The author has an hindex of 2, co-authored 2 publications receiving 4309 citations.

Papers
More filters
Journal ArticleDOI
TL;DR: In selected patients, placement of an intracoronary stent, as compared with balloon angioplasty, results in an improved rate of procedural success, a lower rate of angiographically detected restenosis, a similar rate of clinical events after six months, and a less frequent need for revascularization of the original coronary lesion.
Abstract: Background Coronary-stent placement is a new technique in which a balloon-expandable, stainless-steel, slotted tube is implanted at the site of a coronary stenosis. The purpose of this study was to compare the effects of stent placement and standard balloon angioplasty on angiographically detected restenosis and clinical outcomes. Methods We randomly assigned 410 patients with symptomatic coronary disease to elective placement of a Palmaz-Schatz stent or to standard balloon angioplasty. Coronary angiography was performed at base line, immediately after the procedure, and six months later. Results The patients who underwent stenting had a higher rate of procedural success than those who underwent standard balloon angioplasty (96.1 percent vs. 89.6 percent, P = 0.011), a larger immediate increase in the diameter of the lumen (1.72 ±0.46 vs. 1.23 ±0.48 mm, P<0.001), and a larger luminal diameter immediately after the procedure (2.49 ±0.43 vs. 1.99 ±0.47 mm, P<0.001). At six months, the patients with stented ...

4,300 citations

Journal ArticleDOI
TL;DR: The Stent Restenosis Study (STRESS I) as discussed by the authors compared the safety of elective stent to balloon angioplasty (PTCA) in terms of freedom from clinical events up to 1 year after treatment.
Abstract: We present the completed 1-year follow-up results of the original Stent Restenosis Study (STRESS I), in which 407 patients with symptomatic ischemic heart disease and new lesions of the native coronary circulation were randomly assigned to treatment with either the Palmaz-Schatz coronary stent or conventional percutaneous transluminal coronary angioplasty (PTCA). The present study compares the safety of elective stenting to balloon angioplasty (PTCA) in terms of freedom from clinical events up to 1 year after treatment. Patients were enrolled and treated from January 1991 through February 1993, and follow-up data were collected and verified until July 1995. Ninety-seven percent of all patients had complete follow-up (deceased or alive with known clinical status) beyond 8 months, and 94% beyond 11 months. Anginal status between 9 to 15 months postprocedure was available for 78% of patients. At 1 year, 154 patients (75%) assigned to stent implantation and 141 (70%) to PTCA were free of all clinical events (death, myocardial infarction, or any revascularization procedure), and 162 stent patients (79%) and 149 PTCA patients (74%) were free from death, myocardial infarction, or target lesion revascularization. Symptom-driven target lesion revascularization occurred in 12% of the stent group versus 17% of the PTCA group. None of these differences in clinical events was statistically significant. Only 2 patients in the stent group and 7 in the PTCA group had a first event after 239 days, and freedom from angina at 1 year was reported in equal frequency in both groups (84%). There appear to be no late adverse effects of stent implantation. However, these results are limited by low statistical power, narrow patient selection, and the anticoagulation regimen used in the early experience with this device.

72 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: In this randomized clinical trial involving patients with complex coronary lesions, the use of a sirolimus-eluting stent had a consistent treatment effect, reducing the rates of restenosis and associated clinical events in all subgroups analyzed.
Abstract: Background Preliminary reports of studies involving simple coronary lesions indicate that a sirolimus-eluting stent significantly reduces the risk of restenosis after percutaneous coronary revascularization. Methods We conducted a randomized, double-blind trial comparing a sirolimus-eluting stent with a standard stent in 1058 patients at 53 centers in the United States who had a newly diagnosed lesion in a native coronary artery. The coronary disease in these patients was complex because of the frequent presence of diabetes (in 26 percent of patients), the high percentage of patients with longer lesions (mean, 14.4 mm), and small vessels (mean, 2.80 mm). The primary end point was failure of the target vessel (a composite of death from cardiac causes, myocardial infarction, and repeated percutaneous or surgical revascularization of the target vessel) within 270 days. Results The rate of failure of the target vessel was reduced from 21.0 percent with a standard stent to 8.6 percent with a sirolimus-eluting ...

4,271 citations

Journal ArticleDOI
TL;DR: As compared with a standard coronary stent, a sirolimus-eluting stent shows considerable promise for the prevention of neointimal proliferation, restenosis, and associated clinical events.
Abstract: BACKGROUND: The need for repeated treatment of restenosis of a treated vessel remains the main limitation of percutaneous coronary revascularization. Because sirolimus (rapamycin) inhibits the proliferation of lymphocytes and smooth-muscle cells, we compared a sirolimus-eluting stent with a standard uncoated stent in patients with angina pectoris. METHODS: We performed a randomized, double-blind trial to compare the two types of stents for revascularization of single, primary lesions in native coronary arteries. The trial included 238 patients at 19 medical centers. The primary end point was in-stent late luminal loss (the difference between the minimal luminal diameter immediately after the procedure and the diameter at six months). Secondary end points included the percentage of in-stent stenosis of the luminal diameter and the rate of restenosis (luminal narrowing of 50 percent or more). We also analyzed a composite clinical end point consisting of death, myocardial infarction, and percutaneous or surgical revascularization at 1, 6, and 12 months. RESULTS: At six months, the degree of neointimal proliferation, manifested as the mean (+/-SD) late luminal loss, was significantly lower in the sirolimus-stent group (-0.01+/-0.33 mm) than in the standard-stent group (0.80+/-0.53 mm, P<0.001). None of the patients in the sirolimus-stent group, as compared with 26.6 percent of those in the standard-stent group, had restenosis of 50 percent or more of the luminal diameter (P<0.001). There were no episodes of stent thrombosis. During a follow-up period of up to one year, the overall rate of major cardiac events was 5.8 percent in the sirolimus-stent group and 28.8 percent in the standard-stent group (P<0.001). The difference was due entirely to a higher rate of revascularization of the target vessel in the standard-stent group. CONCLUSIONS: As compared with a standard coronary stent, a sirolimus-eluting stent shows considerable promise for the prevention of neointimal proliferation, restenosis, and associated clinical events.

4,051 citations

Journal ArticleDOI
TL;DR: Alice K. Jacobs, MD, FACC, FAHA, Chair Jeffrey L. Anderson, PhD, CCNS, CCRN, FAH, Chair-Elect - The first female FACC-FAHA board member to be elected in the history of the sport.
Abstract: Alice K. Jacobs, MD, FACC, FAHA, Chair Jeffrey L. Anderson, MD, FACC, FAHA, Chair-Elect Nancy Albert, PhD, CCNS, CCRN, FAHA Mark A. Creager, MD, FACC, FAHA Steven M. Ettinger, MD, FACC Robert A. Guyton, MD, FACC Jonathan L. Halperin, MD, FACC, FAHA Judith S. Hochman, MD, FACC, FAHA

3,040 citations

Journal ArticleDOI
TL;DR: As compared with bare-metal stents, the slow-release, polymer-based, paclitaxel-eluting stent is safe and markedly reduces the rates of clinical and angiographic restenosis at nine months.
Abstract: Background Restenosis after coronary stenting necessitates repeated percutaneous or surgical revascularization procedures. The delivery of paclitaxel to the site of vascular injury may reduce the incidence of neointimal hyperplasia and restenosis. Methods At 73 U.S. centers, we enrolled 1314 patients who were receiving a stent in a single, previously untreated coronary-artery stenosis (vessel diameter, 2.5 to 3.75 mm; lesion length, 10 to 28 mm) in a prospective, randomized, double-blind study. A total of 652 patients were randomly assigned to receive a bare-metal stent, and 662 to receive an identical-appearing, slow-release, polymer-based, paclitaxel-eluting stent. Angiographic follow-up was prespecified at nine months in 732 patients. Results In terms of base-line characteristics, the two groups were well matched. Diabetes mellitus was present in 24.2 percent of patients; the mean reference-vessel diameter was 2.75 mm, and the mean lesion length was 13.4 mm. A mean of 1.08 stents (length, 21.8 mm) were...

2,617 citations

Journal ArticleDOI
TL;DR: The medical profession should play a central role in evaluating the evidence related to drugs, devices, and procedures for the detection, management, and prevention of disease as mentioned in this paper, and when properly applied, expert analysis of available data on the benefits and risks of these therapies and procedures can

2,495 citations