scispace - formally typeset
Search or ask a question
Author

Luís Fernando dos Santos Alves Morgan

Bio: Luís Fernando dos Santos Alves Morgan is an academic researcher from Universidade Federal de Minas Gerais. The author has contributed to research in topics: Root canal & Medicine. The author has an hindex of 4, co-authored 10 publications receiving 98 citations.

Papers
More filters
Journal ArticleDOI
TL;DR: The quantitative analysis showed significant differences between different posts and depths, and it was revealed that the quantity of luminous energy transmitted depends on the type of post and that for all of them there was a significant reduction of the quantities of light transmitted as the depth increased.

76 citations

Journal ArticleDOI
TL;DR: Generally, the simplification of steps in the adhesive system and the polymerization reaction of resin adhesives and cements produced a direct effect on the quality of the adhesive post/dentin substrate interface.
Abstract: This in vitro study evaluated the adhesive interface of intraradicular fiber glass posts and root dentin using scanning electron microscopy (SEM). Forty-eight single-rooted premolars were randomly divided into 6 groups consisting of chemical, dual, or light cured adhesive systems combined with either chemical or dual cure resin cements. Scanning electron microscopic analysis showed the best results for continuity, density and morphology of the hybrid layer and resin tags for the combination of a self-cure adhesive with self-cure cement resin, followed by a dual-cure adhesive with self-cure cement resin, and finally a light-cure adhesive with self-cure cement. For the dual-cure resin cement, the same relation may be observed. The apical third was the most critical region for evaluated the criteria for all combinations of materials (Kruskal-Wallis and Friedman tests; p<0.001). Generally, the simplification of steps in the adhesive system and the polymerization reaction of resin adhesives and cements produced a direct effect on the quality of the adhesive post/dentin substrate interface.

13 citations

Journal ArticleDOI
TL;DR: Adequate photopolymerization should be considered during cementation when using dual polymerization self-etching resin cements, because of the high level of cytotoxicity of these cements.
Abstract: Aim: The aim of this study was to evaluate the correlation between the cytotoxicity and degree of conversion (DC) of self-etch resin cements with or without photopolymerization. Materials and Methods: Three self-etching resin cements with or without photopolymerization were evaluated. Six test groups and one control group represented by a standardized L929-fibroblast cell culture were formed. The DC was measured by Fourier transform infrared spectrometry and was correlated with cell culture survival. Statistical Analysis: The analysis of variance and Bonferroni–Holm tests were applied (P < 0.05). Results:The results show that, the cytotoxicity of self-etching resin cements is directly related to the DC. With the exception of Unicem, the other cements show some level of cytotoxicity, even with photopolymerization. Conclusion: These results indicate that photopolymerization of dual cure self-etching resin cements decrease toxic effects on cell culture. Adequate photopolymerization should be considered during cementation when using dual polymerization self-etching resin cements.

8 citations

Journal ArticleDOI
TL;DR: A delayed post preparation of the root space, following the root canal filling, is recommended and, for all of the evaluated thirds, delayed preparation showed greater bond strength than immediate preparation.
Abstract: Background: To assist the retention of restorations prepared in endodontically treated teeth, fiber posts are widely used in dental practice. The ideal time to prepare space for the post is still controversial. Aim: The purpose of this study was to evaluate the effects of immediate and delayed postspace preparation on the retention of the self-adhesive resin cement. Materials and Methods: Twelve bovine teeth were used with sectioned roots standardized to 19 mm. The teeth were properly instrumented and filled with gutta-percha and eugenol-free cement AH Plus. Two experimental groups (n = 6) were created based on the different times of post preparation (immediate and delayed). Using cemented cylindrical fiber posts, the teeth were put in acrylic resin and polyvinyl chloride tubes, where the cuts were made. Two slices were obtained from the cervical third, two from the medium third and two from the apical third. Subsequently, the samples were subjected into push-out tests. Statistical analysis were performed using ANOVA and Tukey's test (P = 5%). Results: The results indicated that, for all of the evaluated thirds, delayed preparation showed greater bond strength than immediate preparation. Conclusion: A delayed post preparation of the root space, following the root canal filling, is recommended.

7 citations

Journal ArticleDOI
TL;DR: A quantitative investigation of the radial transmission of light through different fiber posts and its influence on the Knoop hardness number (KHN) and bond strength (BS) of a dual-cure self-adhesive resin cement at 3 different depths found LT depended on the type of post and on depth.
Abstract: Context: Light transmission (LT) into deeper areas of the dentin root is limited. Aim: The aim of this study is to perform a quantitative investigation of the radial transmission of light (LT) through different fiber posts and its influence on the Knoop hardness number (KHN) and bond strength (BS) of a dual-cure self-adhesive resin cement at 3 different depths. Materials and Methods: Four types of fiber posts (2 translucent and 2 conventional) were used. LT and KHN analyses were performed in a specially designed matrix, which allowed measurements at 3 different depths. LT was measured using a volt-ampere meter while KHN tests were performed in a microhardness tester. For BS analysis, endodontically treated bovine roots were divided into 4 groups, each group receiving one type of post. After cementation, cross sections of the root were tested for resistance to displacement using a universal testing machine. Statistical Analysis Used: Statistical analysis was performed by using this ANOVA and Tukey's test. Results: For LT, translucent posts showed significantly higher values at all depths compared to the conventional ones. For all posts, LT decreased at the deeper depths. The KHN results showed no statistical differences among the different posts, regardless of depth. For BS, a translucent post showed the highest values, and comparative analyses between the different depths of posts also showed statistically significant differences while comparisons among the different depths of the same post showed no differences. Conclusions: LT depended on the type of post and on depth. The type of post did not significantly influence the cement KHN. A translucent post showed higher BS in pooled data.

3 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: Whether the light-transmitting ability of marketed fiber posts reflected the manufacturers’ claims for translucency was verified, and a statistically significant difference was found for Dentin Post X and FRC Postec Plus in comparison with Reforpost, FibreKleer, Tech21 X-OP, and Composipost.
Abstract: If proper polymerization of resin-based cements is to be achieved for fiber post luting, light activation is needed for photo-curing agents, recommended for self-curing materials. The study was aimed at verifying whether the light-transmitting ability of marketed fiber posts reflected the manufacturers' claims for translucency. Ten posts per type were light-irradiated with a curing unit. Spectrophotometric measurements of the amount of photons reaching different post levels were taken. Data were statistically analyzed (linear regression, two-way ANOVA; alpha = 0.05). No light transmission was recorded through FibreKleer and Tech21 X-OP. For the other posts, light intensity decreased from coronal to apical and rose again at the apical tip, where it peaked for GC Fiber Post, Macrolock Illusion Post, and Radix Fiber Post. Light transmission was significantly higher at the coronal level. A statistically significant difference in translucency was found for Dentin Post X and FRC Postec Plus in comparison with Reforpost, FibreKleer, Tech21 X-OP, and Composipost.

115 citations

Journal ArticleDOI
TL;DR: Cementation of fiber post with no light transmitting ability using a dual-cured resin cement resulted in lower E and VH of the cement layer, and lower percentage of continuous C-RD and C-FP interface in comparison to cementation of light transmitting fiber post.

66 citations

Journal ArticleDOI
TL;DR: Current concepts based on the literature from the past 10 years or so are focused on, and treatment guidelines based on that research are provided.

61 citations

Journal ArticleDOI
TL;DR: It can be concluded that the self-adhesive cement RelyX U100 showed the highest bond strength to the root canal in the student's group, and its performance was not affected by the operator's experience.
Abstract: Clinical Relevance RelyX U100 (commercially available outside Brazil as RelyX Unicem) was shown not to be affected by the operator's experience and therefore seems to be more suitable for use by less experienced clinicians.

50 citations

Journal ArticleDOI
TL;DR: The self-adhesive cement appears to be a good alternative for luting fiber posts due to the high push-out bond strengths and lower polymerization stress values.
Abstract: PURPOSE To evaluate the effect of mechanical cycling and cementation strategies on the push-out bond strength between fiber posts and root dentin and the polymerization stresses produced using three resin cements. MATERIALS AND METHODS Eighty bovine mandibular teeth were sectioned to a length of 16 mm, prepared to 12 mm, and embedded in self-curing acrylic resin. The specimens were then distributed into 8 groups (n = 10): Gr1 - Scotchbond Multi Purpose + RelyX ARC; Gr2 - Scotchbond Multi Purpose + RelyX ARC + mechanical cycling; Gr3 - AdheSE + Multilink Automix; Gr4 - AdheSE + Multilink Automix + mechanical cycling; Gr5 - phosphoric acid + RelyX U100 (self-adhesive cement); Gr6 - phosphoric acid+ RelyX U100 + mechanical cycling; Gr7 - RelyX U100; Gr8 - RelyX U100 + mechanical cycling. The values obtained from the push-out bond strength test were submitted to two-way ANOVA and Tukey's test (p = 0.05), while the values obtained from the polymerization stress test were subjected to one-way ANOVA and Tukey's test (α = 0.05). RESULTS Mechanical cycling did not affect the bond strength values (p = 0.236), while cementation strategies affected the push-out bond strength (p < 0.001). Luting with RelyX U100 and Scotch Bond Multi Purpose + RelyX ARC yielded higher push-out bond strength values. The polymerization stress results were affected by the factor "cement" (p = 0.0104): the self-adhesive cement RelyX U100 exhibited the lowest values, RelyX ARC resulted in the highest values, while Multilink Automix presented values statistically similar to the other two cements. CONCLUSION The self-adhesive cement appears to be a good alternative for luting fiber posts due to the high push-out bond strengths and lower polymerization stress values.

48 citations