scispace - formally typeset
Search or ask a question
Author

M. Toppi

Bio: M. Toppi is an academic researcher from Sapienza University of Rome. The author has contributed to research in topics: Particle therapy & Range (particle radiation). The author has an hindex of 13, co-authored 37 publications receiving 303 citations. Previous affiliations of M. Toppi include Istituto Nazionale di Fisica Nucleare.

Papers
More filters
Journal ArticleDOI
TL;DR: This proof-of-principle test on a patient assessed that the technique is feasible with negligible background to medical personnel and confirmed that the expectations obtained with Monte Carlo simulations starting from diagnostic PET images are correct.

32 citations

Journal ArticleDOI
TL;DR: The design of a new tracking device for beam range real-time monitoring in pencil beam carbon ion therapy is presented and detector reconstruction efficiency for charged particle emission profile is evaluated using a Monte Carlo simulation considering a quasi-realistic case of a non-homogenous phantom.

31 citations

Journal ArticleDOI
TL;DR: The attenuation of 4He primary particles and the build-up of secondary charged fragments at various depths in water and polymethyl methacrylate were investigated experimentally for 120 and 200 MeV u-1 beams delivered by the synchrotron at the Heidelberg Ion-Beam Therapy Center, Heidelburg.
Abstract: Recently, the use of 4He particles in cancer radiotherapy has been reconsidered as they potentially represent a good compromise between protons and 12C ions. The first step to achieve this goal is the development of a dedicated treatment planning system, for which basic physics information such as the characterization of the beam lateral scattering and fragmentation cross sections are required. In the present work, the attenuation of 4He primary particles and the build-up of secondary charged fragments at various depths in water and polymethyl methacrylate were investigated experimentally for 120 and 200 MeV u-1 beams delivered by the synchrotron at the Heidelberg Ion-Beam Therapy Center, Heidelberg. Species and isotope identification was accomplished combining energy loss and time-of-flight measurements. Differential yields and energy spectra of all fragments types were recorded between 0° and 20° with respect to the primary beam direction.

30 citations

Journal ArticleDOI
TL;DR: In this paper, the yields of prompt photons produced by the interaction of helium, carbon and oxygen ion beams with a poly-methyl methacrylate (PMMA) beam stopping target were evaluated.
Abstract: Charged particle beams are used in particle therapy (PT) to treat oncological patients due to their selective dose deposition in tissues with respect to the photons and electrons used in conventional radiotherapy. Heavy (Z > 1) PT beams can additionally be exploited for their high biological effectiveness in killing cancer cells. Nowadays, protons and carbon ions are used in PT clinical routines. Recently, interest in the potential application of helium and oxygen beams has been growing. With respect to protons, such beams are characterized by their reduced multiple scattering inside the body, increased linear energy transfer, relative biological effectiveness and oxygen enhancement ratio. The precision of PT demands online dose monitoring techniques, crucial to improving the quality assurance of any treatment: possible patient mis-positioning and biological tissue changes with respect to the planning CT scan could negatively affect the outcome of the therapy. The beam range confined in the irradiated target can be monitored thanks to the neutral or charged secondary radiation emitted by the interactions of hadron beams with matter. Among these secondary products, prompt photons are produced by nuclear de-excitation processes, and at present, different dose monitoring and beam range verification techniques based on prompt-γ detection are being proposed. It is hence of importance to perform γ yield measurement in therapeutic-like conditions. In this paper we report on the yields of prompt photons produced by the interaction of helium, carbon and oxygen ion beams with a poly-methyl methacrylate (PMMA) beam stopping target. The measurements were performed at the Heidelberg Ion-Beam Therapy Center (HIT) with beams of different energies. An LYSO scintillator, placed at [Formula: see text] and [Formula: see text] with respect to the beam direction, was used as the photon detector. The obtained γ yields for the carbon ion beams are compared with results from the literature, while no other results from helium and oxygen beams have been published yet. A discussion on the expected resolution of a slit camera detector is presented, demonstrating the feasibility of a prompt-γ-based monitoring technique for PT treatments using helium, carbon and oxygen ion beams.

28 citations

Journal ArticleDOI
TL;DR: The yields of prompt photons produced by the interaction of helium, carbon and oxygen ion beams with a poly-methyl methacrylate (PMMA) beam stopping target are reported on, demonstrating the feasibility of a prompt-γ-based monitoring technique for PT treatments using helium,carbon and oxygen Ion beams.
Abstract: Charged particle beams are used in Particle Therapy (PT) to treat oncological patients due to their selective dose deposition in tissues and to their high biological effect in killing cancer cells with respect to photons and electrons used in conventional radiotherapy. Nowadays, protons and carbon ions are used in PT clinical routine but, recently, the interest on the potential application of helium and oxygen beams is growing due to their reduced multiple scattering inside the body and increased linear energy transfer, relative biological effectiveness and oxygen enhancement ratio. The precision of PT demands for online dose monitoring techniques, crucial to improve the quality assurance of treatments. The beam range confined in the irradiated target can be monitored thanks to the neutral or charged secondary radiation emitted by the interactions of hadron beams with matter. Prompt photons are produced by nuclear de-excitation processes and, at present, different dose monitoring and beam range verification techniques based on the prompt {\gamma} detection have been proposed. It is hence of importance to perform the {\gamma} yield measurement in therapeutical-like conditions. In this paper we report the yields of prompt photons produced by the interaction of helium, carbon and oxygen ion beams with a PMMA target. The measurements were performed at the Heidelberg Ion-beam Therapy center (HIT) with beams of different energies. A LYSO scintillator has been used as photon detector. The obtained {\gamma} yields for $^{12}$C ion beams are compared with results from literature, while no other results from $^{4}$He and $^{16}$O beams have been published yet. A discussion on the expected resolution of a slit camera detector is presented, demonstrating the feasibility of a prompt-{\gamma} based monitoring technique for PT treatments using helium, carbon and oxygen ion beams.

28 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: Several randomized trials of charged-particle therapies that are ongoing are reviewed, with results that will enable selective delivery to patients who are most likely to benefit from them and aspects related to radiobiology, including the immune response and hypoxia, which will need to be taken into consideration in future randomized trials to fully exploit the potential of charged particles.
Abstract: Radiotherapy with high-energy charged particles has become an attractive therapeutic option for patients with several tumour types because this approach better spares healthy tissue from radiation than conventional photon therapy. The cost associated with the delivery of charged particles, however, is higher than that of even the most elaborate photon-delivery technologies. Reliable evidence of the relative cost-effectiveness of both modalities can only come from the results of randomized clinical trials. Thus, the hurdles that currently limit direct comparisons of these two approaches in clinical trials, especially those related to insurance coverage, should be removed. Herein, we review several randomized trials of charged-particle therapies that are ongoing, with results that will enable selective delivery to patients who are most likely to benefit from them. We also discuss aspects related to radiobiology, including the immune response and hypoxia, which will need to be taken into consideration in future randomized trials to fully exploit the potential of charged particles.

309 citations

Journal ArticleDOI
TL;DR: Research in applied nuclear physics, including nuclear interactions, dosimetry, image guidance, range verification, novel accelerators and beam delivery technologies, can significantly improve the clinical outcome in particle therapy.
Abstract: Charged particle therapy has been largely driven and influenced by nuclear physics. The increase in energy deposition density along the ion path in the body allows reducing the dose to normal tissues during radiotherapy compared to photons. Clinical results of particle therapy support the physical rationale for this treatment, but the method remains controversial because of the high cost and of the lack of comparative clinical trials proving the benefit compared to x-rays. Research in applied nuclear physics, including nuclear interactions, dosimetry, image guidance, range verification, novel accelerators and beam delivery technologies, can significantly improve the clinical outcome in particle therapy. Measurements of fragmentation cross-sections, including those for the production of positron-emitting fragments, and attenuation curves are needed for tuning Monte Carlo codes, whose use in clinical environments is rapidly increasing thanks to fast calculation methods. Existing cross sections and codes are indeed not very accurate in the energy and target regions of interest for particle therapy. These measurements are especially urgent for new ions to be used in therapy, such as helium. Furthermore, nuclear physics hardware developments are frequently finding applications in ion therapy due to similar requirements concerning sensors and real-time data processing. In this review we will briefly describe the physics bases, and concentrate on the open issues.

220 citations

Journal ArticleDOI
TL;DR: In this paper, a review and discussion of the state of the art for all techniques using prompt-gamma detection to improve the quality assurance in hadrontherapy is presented.
Abstract: Secondary radiation emission induced by nuclear reactions is correlated to the path of ions in matter. Therefore, such penetrating radiation can be used for in vivo control of hadrontherapy treatments, for which the primary beam is absorbed inside the patient. Among secondary radiations, prompt-gamma rays were proposed for real-time verification of ion range. Such a verification is a desired condition to reduce uncertainties in treatment planning. For more than a decade, efforts have been undertaken worldwide to promote prompt-gamma-based devices to be used in clinical conditions. Dedicated cameras are necessary to overcome the challenges of a broad- and high-energy distribution, a large background, high instantaneous count rates, and compatibility constraints with patient irradiation. Several types of prompt-gamma imaging devices have been proposed, that are either physically-collimated or electronically collimated (Compton cameras). Clinical tests are now undergoing. Meanwhile, other methods than direct prompt-gamma imaging were proposed, that are based on specific counting using either time-of-flight or photon energy measurements. In the present article, we make a review and discuss the state of the art for all techniques using prompt-gamma detection to improve the quality assurance in hadrontherapy.

178 citations

Journal ArticleDOI
TL;DR: This review has aimed to provide a comprehensive update of the most recent advances in the field of radioguided surgery, covering all aspects of radioisotopes that emit γ, β+, and/or β− radiation.
Abstract: Introduction: Radioguided surgery is an ever-evolving part of nuclear medicine. In fact, this nuclear medicine sub-discipline actively bridges non-invasive molecular imaging with surgical care. Nex...

68 citations

Journal ArticleDOI
TL;DR: The measurements of charged particle fluxes produced by the interaction of a 220 MeV/u carbon ion beam at GSI, Darmstadt, with a polymethyl methacrylate target are reported and a method to monitor the dose profile and the position of the Bragg peak inside the target is proposed.
Abstract: The radiation used in hadrontherapy treatments interacts with the patient body producing secondary particles, either neutral or charged, that can be used for dose and Bragg peak monitoring and to provide a fast feedback on the treatment plans. Recent results obtained from the authors on simplified setups (mono-energetic primary beams interacting with homogeneous tissue-like target) have already indicated the correlation that exists between the flux of these secondaries coming from the target (e.g. protons and photons) and the position of the primary beam Bragg peak. In this paper, the measurements of charged particle fluxes produced by the interaction of a 220 MeV/u carbon ion beam at GSI, Darmstadt, with a polymethyl methacrylate target are reported. The emission region of protons (p), deuterons (d) and tritons (t) has been characterized using a drift chamber while the particle time-of-flight, used to compute the kinetic energy spectra, was measured with a LYSO scintillator. The energy released in the LYSO crystal was used for particle identification purposes. The measurements were repeated with the setup at 60° and 90° with respect to the primary beam direction. The accuracy on the fragments emission profile reconstruction and its relationship with the Bragg peak position have been studied. Based on the acquired experimental evidence, a method to monitor the dose profile and the position of the Bragg peak inside the target is proposed.

63 citations