Journal ArticleDOI
TL;DR: In this article, the authors evaluated CAD/CAM technologies and materials for implementation into the workflow for producing these orthodontic appliances (TPPs), manufactured by different techniques and materials: additive manufacturing (AM) and subtractive manufacturing (SM) technologies vs. conventional manufacturing.
Abstract: CAD/CAM technologies and materials have the potential to improve the treatment of Robin Sequence with orthodontic appliances (Tubingen palatal plate, TPP). However, studies on the provided suitability and safety are lacking. The present study evaluates CAD/CAM technologies and materials for implementation into the workflow for producing these orthodontic appliances (TPPs), manufactured by different techniques and materials: additive manufacturing (AM) and subtractive manufacturing (SM) technologies vs. conventional manufacturing. The fracture load was obtained in a universal testing machine, and the breaking behavior of each bunch, as well as the necessity of adding a safety wire, was evaluated. The minimum fracture load was used to calculate the safety factor (SF) provided by each material. Secondary factors included manufacturing time, material cost and reproducibility. Dental LT clear showed the highest fracture load and best breaking behavior among AM materials. The highest fracture load and safety factor were obtained with Smile polyether ether ketone (PEEK). For the prototyping stage, the use of a Freeprint tray (SF = 114.145) is recommended. For final manufacturing, either the cost-effective approach, Dental LT clear (SF = 232.13%), or the safest but most expensive approach, Smile PEEK (SF = 491.48%), can be recommended.

12 citations

Journal ArticleDOI
TL;DR: In this article, the accuracy of CAD/CAM manufactured orthodontic appliances for this kind of application was evaluated using a 3D inspection software (Geomagic Control X, 3D systems).
Abstract: Different approaches for digital workflows have already been presented for their use in palatal plates for newborns and infants. However, there is no evidence on the accuracy of CAD/CAM manufactured orthodontic appliances for this kind of application. This study evaluates trueness and precision provided by different CAM technologies and materials for these appliances. Samples of a standard palatal stimulation plate were manufactured using stereolithography (SLA), direct light processing (DLP) and subtractive manufacturing (SM). The effect of material (for SM) and layer thickness (for DLP) were also investigated. Specimens were digitized with a laboratory scanner (D2000, 3Shape) and analyzed with a 3D inspection software (Geomagic Control X, 3D systems). For quantitative analysis, differences between 3D datasets were measured using root mean square (RMS) error values for trueness and precision. For qualitative analysis, color maps were generated to detect locations of deviations within each sample. SM showed higher trueness and precision than AM technologies. Reducing layer thickness in DLP did not significantly increase accuracy, but prolonged manufacturing time. All materials and technologies met the clinically acceptable range and are appropriate for their use. DLP with 100 µm layer thickness showed the highest efficiency, obtaining high trueness and precision within the lowest manufacturing time.

12 citations

Journal ArticleDOI
TL;DR: In this article, different additive manufacturing technologies (Dental LT Clear, Freeprint Splint, V-Print Splint) as well as subtractive technologies (Yamahachi PMMA, Smile PEEK) were evaluated and compared to the cold polymerizing PMMA (Orthocryl) used for conventional TPPs.
Abstract: The study’s aim was to test and evaluate different class IIa CAD/CAM materials for their potential use as the Tubingen Palatal Plate (TPP) orthodontic appliance. Materials manufactured by additive manufacturing technologies (Dental LT Clear, Freeprint Splint, Freeprint Ortho, V-Print Splint) as well as subtractive technologies (Yamahachi PMMA, Smile PEEK) were evaluated and compared to the cold polymerizing PMMA (Orthocryl) used for conventional TPPs. The test was carried out using a modified protocol following DIN EN ISO 20795-2:2013, for which materials are pre-conditioned by storage in distilled water for 50 ± 2 h at 37 ± 1 °C. The flexural strength and modulus of each material was then determined by a three-point bending test. Orthocryl showed one of the lowest flexural strength values (93.5 ± 3.0 MPa) while Dental LT Clear exhibited the highest flexural strength (147.7 ± 5.0 MPa; p = 0.0465) among the additive manufacturing materials. Smile PEEK showed the highest value (244.0 ± 1.7 MPa; p

9 citations

Journal ArticleDOI
TL;DR: A user-friendly workflow for in-house manufacturing of these medical appliances proved to have potential for improving NIV in neonates and infants, as well as increasing comfort.
Abstract: The objective of this study was to present a methodology and manufacturing workflow for non-invasive ventilation interfaces (NIV) for neonates and small infants. It aimed to procure a fast and feasible solution for personalized NIV produced in-house with the aim of improving fit and comfort for the patient. Three-dimensional scans were obtained by means of an intraoral (Trios 3) and a facial scanner (3dMd Flex System). Fusion 360 3D-modelling software was employed to automatize the design of the masks and their respective casting molds. These molds were additively manufactured by stereolithography (SLA) and fused filament fabrication (FFF) technologies. Silicone was poured into the molds to produce the medical device. In this way, patient individualized oronasal and nasal masks were produced. An automated design workflow and use of additive manufacturing enabled a fast and feasible procedure. Despite the cost for individualization likely being higher than for standard masks, a user-friendly workflow for in-house manufacturing of these medical appliances proved to have potential for improving NIV in neonates and infants, as well as increasing comfort.

2 citations

Journal ArticleDOI
TL;DR: A semi-automatic and custom-made program, based on Rhinoceros 7 and Grasshopper, was developed to measure the Tübingen Palatal Plate (TPP) as mentioned in this paper .
Abstract: Measuring the dimensions of personalized devices can provide relevant information for the production of future such devices used in various medical specialties. Difficulties with standardizing such measurement and obtaining high accuracy, alongside cost-intensive measuring methodologies, has dampened interest in this practice. This study presents a methodology for automatized measurements of personalized medical appliances of variable shape, in this case an orthodontic appliance known as Tübingen Palatal Plate (TPP). Parameters such as length, width and angle could help to standardize and improve its future use. A semi-automatic and custom-made program, based on Rhinoceros 7 and Grasshopper, was developed to measure the device (via an extraoral scanner digital file). The program has a user interface that allows the import of the desired part, where the user is able to select the necessary landmarks. From there, the program is able to process the digital file, calculate the necessary dimensions automatically and directly export all measurements into a document for further processing. In this way, a solution for reducing the time for measuring multiple dimensions and parts while reducing human error can be achieved.

1 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: In this paper, 15 denture bases were printed with stereolithography and direct light processing (DLP) methods using three build angles: 0°, 45° and 90°, and the differences between 3D datasets were measured using the root mean square (RMS) value for trueness and precision.
Abstract: The topical literature lacks any comparison between stereolithography (SLA) and direct light processing (DLP) printing methods with regard to the accuracy of complete denture base fabrication, thereby utilizing materials certified for this purpose. In order to investigate this aspect, 15 denture bases were printed with SLA and DLP methods using three build angles: 0°, 45° and 90°. The dentures were digitalized using a laboratory scanner (D2000, 3Shape) and analyzed in analyzing software (Geomagic Control X, 3D systems). Differences between 3D datasets were measured using the root mean square (RMS) value for trueness and precision and mean and maximum deviations were obtained for each denture base. The data were statistically analyzed using two-way ANOVA and Tukey's multiple comparison test. A heat map was generated to display the locations of the deviations within the intaglio surface. The overall tendency indicated that SLA denture bases had significantly higher trueness for most build angles compared to DLP (p < 0.001). The 90° build angle may provide the best trueness for both SLA and DLP. With regard to precision, statistically significant differences were found in the build angles only. Higher precision was revealed in the DLP angle of 0° in comparison to the 45° and 90° angles.

40 citations

Journal ArticleDOI
Rupak Dua1, Zuri Rashad1, Joy Spears1, Grace Dunn, Micaela Maxwell1 
22 Nov 2021-Polymers
TL;DR: A systematic review of 3D-printed polyether ether ketone (PEEK) is presented in this article, where the authors found that most of the applications are still in the research phase.
Abstract: Polyether ether ketone (PEEK) is an organic polymer that has excellent mechanical, chemical properties and can be additively manufactured (3D-printed) with ease. The use of 3D-printed PEEK has been growing in many fields. This article systematically reviews the current status of 3D-printed PEEK that has been used in various areas, including medical, chemical, aerospace, and electronics. A search of the use of 3D-printed PEEK articles published until September 2021 in various fields was performed using various databases. After reviewing the articles, and those which matched the inclusion criteria set for this systematic review, we found that the printing of PEEK is mainly performed by fused filament fabrication (FFF) or fused deposition modeling (FDM) printers. Based on the results of this systematic review, it was concluded that PEEK is a versatile material, and 3D-printed PEEK is finding applications in numerous industries. However, most of the applications are still in the research phase. Still, given how the research on PEEK is progressing and its additive manufacturing, it will soon be commercialized for many applications in numerous industries.

33 citations

Journal ArticleDOI
TL;DR: In this article, the authors investigated the effect of post-rinsing time on the flexural strength and cytotoxicity of an SLA printed orthodontic splint material.

26 citations

Journal ArticleDOI
01 Sep 2022-Polymers
TL;DR: The paper concludes with the viability of the described method and material upon interdisciplinary clinical evaluation of experts from departments of orthodontics and cleft anomalies, pediatric pneumology and phthisiology, and pediatric otorhinolaryngology.
Abstract: This paper introduces a complex novel concept and methodology for the creation of personalized biomedical appliances 3D-printed from certified biocompatible photopolymer resin Dental LT Clear (V2). The explained workflow includes intraoral and CT scanning, patient virtualization, digital appliance design, additive manufacturing, and clinical application with evaluation of the appliance intended for patients with cranio-facial syndromes. The presented concept defines virtual 3D fusion of intraoral optical scan and segmented CT as sufficient and accurate data defining the 3D surface of the face, intraoral and airway morphology necessary for the 3D design of complex personalized intraoral and extraoral parts of the orthopedic appliance. A central aspect of the concept is a feasible utilization of composite resin for biomedical prototyping of the sequence of marginally different appliances necessary to keep the pace with the patient rapid growth. Affordability, noninvasiveness, and practicality of the appliance update process shall be highlighted. The methodology is demonstrated on a particular case of two-year-old infant with Pierre Robin sequence. Materialization by additive manufacturing of this photopolymer provides a highly durable and resistant-to-fracture two-part appliance similar to a Tübingen palatal plate, for example. The paper concludes with the viability of the described method and material upon interdisciplinary clinical evaluation of experts from departments of orthodontics and cleft anomalies, pediatric pneumology and phthisiology, and pediatric otorhinolaryngology.

15 citations

Journal ArticleDOI
TL;DR: In this article, the authors evaluated CAD/CAM technologies and materials for implementation into the workflow for producing these orthodontic appliances (TPPs), manufactured by different techniques and materials: additive manufacturing (AM) and subtractive manufacturing (SM) technologies vs. conventional manufacturing.
Abstract: CAD/CAM technologies and materials have the potential to improve the treatment of Robin Sequence with orthodontic appliances (Tubingen palatal plate, TPP). However, studies on the provided suitability and safety are lacking. The present study evaluates CAD/CAM technologies and materials for implementation into the workflow for producing these orthodontic appliances (TPPs), manufactured by different techniques and materials: additive manufacturing (AM) and subtractive manufacturing (SM) technologies vs. conventional manufacturing. The fracture load was obtained in a universal testing machine, and the breaking behavior of each bunch, as well as the necessity of adding a safety wire, was evaluated. The minimum fracture load was used to calculate the safety factor (SF) provided by each material. Secondary factors included manufacturing time, material cost and reproducibility. Dental LT clear showed the highest fracture load and best breaking behavior among AM materials. The highest fracture load and safety factor were obtained with Smile polyether ether ketone (PEEK). For the prototyping stage, the use of a Freeprint tray (SF = 114.145) is recommended. For final manufacturing, either the cost-effective approach, Dental LT clear (SF = 232.13%), or the safest but most expensive approach, Smile PEEK (SF = 491.48%), can be recommended.

12 citations