scispace - formally typeset
Search or ask a question
Author

Marco A. Costa

Bio: Marco A. Costa is an academic researcher from University Hospitals of Cleveland. The author has contributed to research in topics: Stent & Restenosis. The author has an hindex of 58, co-authored 266 publications receiving 17146 citations. Previous affiliations of Marco A. Costa include University of Florida & University of Florida Health.


Papers
More filters
Journal ArticleDOI
TL;DR: This document may be broadly used as a standard reference regarding the current state of theIVOCT imaging modality, intended for researchers and clinicians who use IVOCT and analyze IVO CT data.

1,501 citations

Journal ArticleDOI
TL;DR: In this article, the impact of individual response variability to clopidogrel on clinical outcomes and current and future directions for its management is reviewed. But, despite the use of clopidine, a considerable number of patients continue to have cardiovascular events.

940 citations

Journal ArticleDOI
TL;DR: In this article, the safety and efficacy of sirolimus-coated BX Velocity stents were evaluated in 30 patients with angina pectoris electively treated with two different formulations of SIROlimuscoated stents (slow release and fast release).
Abstract: BACKGROUND: Restenosis remains an important limitation of interventional cardiology. Therefore, we aimed to determine the safety and efficacy of sirolimus (a cell-cycle inhibitor)-coated BX Velocity stents. METHODS AND RESULTS: Thirty patients with angina pectoris were electively treated with 2 different formulations of sirolimus-coated stents (slow release [SR], n=15, and fast release [FR], n=15). All stents were successfully delivered, and patients were discharged without clinical complications. Independent core laboratories analyzed angiographic and 3D volumetric intravascular ultrasound data (immediately after procedure and at 4-month follow-up). Eight-month clinical follow-up was obtained for all patients. There was minimal neointimal hyperplasia in both groups (11.0+/-3.0% in the SR group and 10.4+/-3.0% in the FR group, P:=NS) by ultrasound and quantitative coronary angiography (in-stent late loss, 0.09+/-0.3 mm [SR] and -0.02+/-0.3 mm [FR]; in-lesion late loss, 0.16+/-0.3 mm [SR] and -0.1+/-0.3 mm [FR]). No in-stent or edge restenosis (diameter stenosis >or=50%) was observed. No major clinical events (stent thrombosis, repeat revascularization, myocardial infarction, or death) had occurred by 8 months. CONCLUSIONS: The implantation of sirolimus-coated BX Velocity stents is feasible and safe and elicits minimal neointimal proliferation. Additional placebo-controlled trials are required to confirm these promising results.

833 citations

Journal ArticleDOI
TL;DR: The aim of the present Expert Review Document is to address the methodology, terminology and clinical applications of OCT for qualitative and quantitative assessment of coronary arteries and atherosclerosis.
Abstract: Optical coherence tomography (OCT) is a novel intravascular imaging modality, based on infrared light emission, that enables a high resolution arterial wall imaging, in the range of 10-20 microns. This feature of OCT allows the visualization of specific components of the atherosclerotic plaques. The aim of the present Expert Review Document is to address the methodology, terminology and clinical applications of OCT for qualitative and quantitative assessment of coronary arteries and atherosclerosis.

782 citations

Journal ArticleDOI
TL;DR: This study demonstrates a sustained suppression of neointimal proliferation by sirolimus-eluting Bx VELOCITY stents 1 year after implantation.
Abstract: BACKGROUND: We have previously reported a virtual absence of neointimal hyperplasia 4 months after implantation of sirolimus-eluting stents. The aim of the present investigation was to determine whether these results are sustained over a period of 1 year. METHODS AND RESULTS: Forty-five patients with de novo coronary disease were successfully treated with the implantation of a single sirolimus-eluting Bx VELOCITY stent in Sao Paulo, Brazil (n=30, 15 fast release [group I, GI] and 15 slow release [GII]) and Rotterdam, The Netherlands (15 slow release, GIII). Angiographic and volumetric intravascular ultrasound (IVUS) follow-up was obtained at 4 and 12 months (GI and GII) and 6 months (GIII). In-stent minimal lumen diameter and percent diameter stenosis remained essentially unchanged in all groups (at 12 months, GI and GII; at 6 months, GIII). Follow-up in-lesion minimal lumen diameter was 2.28 mm (GIII), 2.32 mm (GI), and 2.48 mm (GII). No patient approached the >/=50% diameter stenosis at 1 year by angiography or IVUS assessment, and no edge restenosis was observed. Neointimal hyperplasia, as detected by IVUS, was virtually absent at 6 months (2+/-5% obstruction volume, GIII) and at 12 months (GI=2+/-5% and GII=2+/-3%). CONCLUSIONS: This study demonstrates a sustained suppression of neointimal proliferation by sirolimus-eluting Bx VELOCITY stents 1 year after implantation.

695 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: March 5, 2019 e1 WRITING GROUP MEMBERS Emelia J. Virani, MD, PhD, FAHA, Chair Elect On behalf of the American Heart Association Council on Epidemiology and Prevention Statistics Committee and Stroke Statistics Subcommittee.
Abstract: March 5, 2019 e1 WRITING GROUP MEMBERS Emelia J. Benjamin, MD, ScM, FAHA, Chair Paul Muntner, PhD, MHS, FAHA, Vice Chair Alvaro Alonso, MD, PhD, FAHA Marcio S. Bittencourt, MD, PhD, MPH Clifton W. Callaway, MD, FAHA April P. Carson, PhD, MSPH, FAHA Alanna M. Chamberlain, PhD Alexander R. Chang, MD, MS Susan Cheng, MD, MMSc, MPH, FAHA Sandeep R. Das, MD, MPH, MBA, FAHA Francesca N. Delling, MD, MPH Luc Djousse, MD, ScD, MPH Mitchell S.V. Elkind, MD, MS, FAHA Jane F. Ferguson, PhD, FAHA Myriam Fornage, PhD, FAHA Lori Chaffin Jordan, MD, PhD, FAHA Sadiya S. Khan, MD, MSc Brett M. Kissela, MD, MS Kristen L. Knutson, PhD Tak W. Kwan, MD, FAHA Daniel T. Lackland, DrPH, FAHA Tené T. Lewis, PhD Judith H. Lichtman, PhD, MPH, FAHA Chris T. Longenecker, MD Matthew Shane Loop, PhD Pamela L. Lutsey, PhD, MPH, FAHA Seth S. Martin, MD, MHS, FAHA Kunihiro Matsushita, MD, PhD, FAHA Andrew E. Moran, MD, MPH, FAHA Michael E. Mussolino, PhD, FAHA Martin O’Flaherty, MD, MSc, PhD Ambarish Pandey, MD, MSCS Amanda M. Perak, MD, MS Wayne D. Rosamond, PhD, MS, FAHA Gregory A. Roth, MD, MPH, FAHA Uchechukwu K.A. Sampson, MD, MBA, MPH, FAHA Gary M. Satou, MD, FAHA Emily B. Schroeder, MD, PhD, FAHA Svati H. Shah, MD, MHS, FAHA Nicole L. Spartano, PhD Andrew Stokes, PhD David L. Tirschwell, MD, MS, MSc, FAHA Connie W. Tsao, MD, MPH, Vice Chair Elect Mintu P. Turakhia, MD, MAS, FAHA Lisa B. VanWagner, MD, MSc, FAST John T. Wilkins, MD, MS, FAHA Sally S. Wong, PhD, RD, CDN, FAHA Salim S. Virani, MD, PhD, FAHA, Chair Elect On behalf of the American Heart Association Council on Epidemiology and Prevention Statistics Committee and Stroke Statistics Subcommittee

5,739 citations

Journal ArticleDOI
TL;DR: This year's edition of the Statistical Update includes data on the monitoring and benefits of cardiovascular health in the population, metrics to assess and monitor healthy diets, an enhanced focus on social determinants of health, a focus on the global burden of cardiovascular disease, and further evidence-based approaches to changing behaviors, implementation strategies, and implications of the American Heart Association’s 2020 Impact Goals.
Abstract: Background: The American Heart Association, in conjunction with the National Institutes of Health, annually reports on the most up-to-date statistics related to heart disease, stroke, and cardiovas...

5,078 citations

Journal ArticleDOI
TL;DR: Criteria for assessment of death, myocardial infarction, repeat revascularization, and stent thrombosis were developed and provide consistency across studies that can facilitate the evaluation of safety and effectiveness of these devices.
Abstract: Background— Although most clinical trials of coronary stents have measured nominally identical safety and effectiveness end points, differences in definitions and timing of assessment have created confusion in interpretation. Methods and Results— The Academic Research Consortium is an informal collaboration between academic research organizations in the United States and Europe. Two meetings, in Washington, DC, in January 2006 and in Dublin, Ireland, in June 2006, sponsored by the Academic Research Consortium and including representatives of the US Food and Drug Administration and all device manufacturers who were working with the Food and Drug Administration on drug-eluting stent clinical trial programs, were focused on consensus end point definitions for drug-eluting stent evaluations. The effort was pursued with the objective to establish consistency among end point definitions and provide consensus recommendations. On the basis of considerations from historical legacy to key pathophysiological mechani...

4,994 citations

Journal ArticleDOI
TL;DR: The 2017-18 FAHA/FACC/FAHA Education and Research Grants will be focused on advancing the profession’s understanding of central nervous system disorders and the management of post-traumatic stress disorder.

4,556 citations

Journal ArticleDOI
TL;DR: Authors/Task Force Members: Franz-Josef Neumann* (ESC Chairperson) (Germany), Miguel Sousa-Uva* (EACTS Chair person) (Portugal), Anders Ahlsson (Sweden), Fernando Alfonso (Spain), Adrian P. Banning (UK), Umberto Benedetto (UK).

4,342 citations