scispace - formally typeset
Search or ask a question
Author

Mario Kupnik

Bio: Mario Kupnik is an academic researcher from Technische Universität Darmstadt. The author has contributed to research in topics: Capacitive micromachined ultrasonic transducers & Ultrasonic sensor. The author has an hindex of 31, co-authored 177 publications receiving 2728 citations. Previous affiliations of Mario Kupnik include AVL & Vienna University of Technology.


Papers
More filters
Proceedings ArticleDOI
01 Nov 2008
TL;DR: In this paper, the mass-spring-damper model used for many MEMS structures accurately captures the behavior of a CMUT with a circular plate and provided equations for the CMUT's equivalent massspringdamper parameters, pull-in point, and equivalent circuit parameters.
Abstract: A small-signal equivalent circuit model and FEM often guide CMUT design The small-signal model is usually derived using a combination of numerical and FEM analysis A strictly analytical approach to CMUT design is desired because it provides design intuition and efficient numerical analysis In this paper, we show that the mass-spring-damper model used for many MEMS structures accurately captures the behavior of a CMUT with a circular plate We provide equations for the CMUT's equivalent mass-spring-damper parameters, pull-in point, and equivalent circuit parameters Comparison with FEM shows that the model accurately captures the CMUT's behavior for a wide range of designs Using this model, we can derive simple design equations, calculate the small-signal model for frequency response simulations, and simulate the CMUT's large-signal transient behavior

149 citations

Journal ArticleDOI
TL;DR: The results presented in this paper demonstrate that large-area CMUTs, which produce high-intensity ultrasound, can be fabricated for transmitting directional sound with parametric arrays.
Abstract: In this study, we examine the use of capacitive micromachined ultrasonic transducers (CMUTs) with vacuum- sealed cavities for transmitting directional sound with parametric arrays. We used finite element modeling to design CMUTs with 40-mum- and 60-mum-thick membranes to have resonance frequencies of 46 kHz and 54 kHz, respectively. The wafer bonding approach used to fabricate the CMUTs provides good control over device properties and the capability to fabricate CMUTs with large diameter membranes and deep cavities. Each CMUT is 8 cm in diameter and consists of 284 circular membranes. Each membrane is 4 mm in diameter. Characterization of the fabricated CMUTs shows they have center frequencies of 46 kHz and 55 kHz and 3 dB bandwidths of 1.9 kHz and 5.3 kHz for the 40-mum- and 60-mum-thick membrane devices, respectively. With dc bias voltages of 380 V and 350 V and an ac excitation of 200 V peak-to-peak, the CMUTs generate average sound pressure levels, normalized to the device's surface, of 135 dB and 129 dB (re 20 muPa), respectively. When used to generate 5 kHz sound with a parametric array, we measured sound at 3 m with a 6 dB beamwidth of 8.7deg and a sound pressure level of 58 dB. To understand how detector nonlinearity (e.g., the nonlinearity of the microphone used to make the sound level measurements) affects the measured sound pressure level, we made measurements with and without an acoustic low-pass filter placed in front of the microphone; the measured sound levels agree with numerical simulations of the pressure field. The results presented in this paper demonstrate that large-area CMUTs, which produce high-intensity ultrasound, can be fabricated for transmitting directional sound with parametric arrays.

127 citations

Journal ArticleDOI
TL;DR: In this paper, the authors presented the successful fabrication of capacitive micromachined ultrasonic transducers (CMUTs) with an improved insulation layer structure, which is based on consecutive thermal oxidation steps, on local oxidation of silicon (LOCOS), and on direct wafer bonding.
Abstract: We present the successful fabrication of capacitive micromachined ultrasonic transducers (CMUTs) with an improved insulation layer structure. The goal is to improve device reliability (electrical breakdown) and device performance (reduced parasitic capacitance). The fabrication is based on consecutive thermal oxidation steps, on local oxidation of silicon (LOCOS), and on direct wafer bonding. No chemical-mechanical polishing step is required during the device fabrication. Aside from the advantages associated with direct wafer bonding for CMUT fabrication (simple fabrication, cell shape flexibility, wide gap height range, good uniformity, well-known material properties of single-crystal materials, and low intrinsic stress), the main vertical dimension (electrode separation) is determined by thermal oxidation only, which provides excellent vertical tolerance control ( <;10 nm) and unprecedented uniformity across the wafer. Thus, we successfully fabricated CMUTs with gap heights as small as 40 nm with a uniformity of ±2 nm over the entire wafer. This paper demonstrates that reliable parallel-plate electrostatic actuators and sensors with gap heights in the tens of nanometer range can be realized via consecutive thermal oxidation steps, LOCOS, and direct wafer bonding without chemical-mechanical polishing steps.

115 citations

Journal ArticleDOI
TL;DR: Compared frequency response and efficiency of the transducer in conventional and collapse regimes, experimental results show that a collapsed membrane can be used to generate and detect ultrasound more efficiently than a membrane operated in the conventional mode.
Abstract: This paper reports on the experimental characterization of collapse-mode operation of capacitive micromachined ultrasonic transducers (CMUTs). CMUTs are conventionally operated by applying a direct current (DC) bias voltage less than the collapse voltage of the membrane, so that the membrane is deflected toward the bottom electrode. In the conventional regime, there is no contact between the membrane and the substrate; the maximum alternating current (AC) displacement occurs at the center of the membrane. In collapse-mode operation, the DC bias voltage is first increased beyond the collapse voltage, then reduced without releasing the collapsed membrane. In collapse-mode operation, the center of the membrane is always in contact with the substrate. In the case of a circular membrane, the maximum AC displacement occurs along the ring formed between the center and the edge of the membrane. The experimental characterization presented in this paper includes impedance measurements in air, pulse-echo experiments in immersion, and one-way optical displacement measurements in immersion for both conventional and collapse-mode operations. A 205-mum times 205-mum 2-D CMUT array element composed of circular silicon nitride membranes is used in the experiments. In pulse-echo experiments, a custom integrated circuit (IC) comprising a pulse driver, a transmit/receive switch, a wideband low-noise preamplifier, and a line driver is used. By reducing the parasitic capacitance, the use of a custom IC enables pulse-echo measurements at high frequencies with a very small transducer. By comparing frequency response and efficiency of the transducer in conventional and collapse regimes, experimental results show that a collapsed membrane can be used to generate and detect ultrasound more efficiently than a membrane operated in the conventional mode. Furthermore, the center frequency of the collapsed membrane can be changed by varying the applied DC voltage. In this study, the center frequency of a collapsed transducer in immersion is shown to vary from 20 MHz to 28 MHz with applied DC bias; the same transducer operates at 10 MHz in the conventional mode. In conventional mode, the maximum peak-to-peak pressure is 370 kPa on the transducer surface for a 40-ns, 25-V unipolar pulse excitation. In collapse mode, a 25-ns, 25-V unipolar pulse generates 590 kPa pressure at the surface of the transducer

101 citations

Journal ArticleDOI
TL;DR: The first designs and prototypes of an eight-element, concentric-ring, CMUT array to treat upper abdominal cancers are presented and designed to focus 30-50 mm into tissue, and ablate a 2- to 3-cm-diameter tumor within 1 h.
Abstract: Therapeutic ultrasound guided by MRI is a noninvasive treatment that potentially reduces mortality, lowers medical costs, and widens accessibility of treatments for patients. Recent developments in the design and fabrication of capacitive micromachined ultrasonic transducers (CMUTs) have made them competitive with piezoelectric transducers for use in therapeutic ultrasound applications. In this paper, we present the first designs and prototypes of an eight-element, concentric-ring, CMUT array to treat upper abdominal cancers. This array was simulated and designed to focus 30-50 mm into tissue, and ablate a 2- to 3-cm-diameter tumor within 1 h. Assuming a surface acoustic output pressure of 1 MPa peak-to-peak (8.5 W/cm2) at 2.5 MHz, we simulated an array that produced a focal intensity of 680 W/cm2 when focusing to 35 mm. CMUT cells were then designed to meet these frequency and surface acoustic intensity specifications. These cell designs were fabricated as 2.5 mm x 2.5 mm test transducers and used to verify our models. The test transducers were shown to operate at 2.5 MHz with an output pressure of 1.4 MPa peak-to-peak (16.3 W/cm2). With this CMUT cell design, we fabricated a full eight-element array. Due to yield issues, we only developed electronics to focus the four center elements of the array. The beam profile of the measured array deviated from the simulated one because of the crosstalk effects; the beamwidth matched within 10% and sidelobes increased by two times, which caused the measured gain to be 16.6 compared to 27.4.

97 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: Targeted imaging and therapeutic agents will be developed in tandem through close collaboration between academia and biotechnology, information technology and pharmaceutical industries to improve outcome and reduce collateral effects.

654 citations

Journal ArticleDOI
TL;DR: This paper presents a meta-analyses of the chiral stationary phase transition of Na6(CO3)(SO4)/ Na2SO4 using a high-performance liquid chromatography apparatus for the determination of Na2CO3(SO4).
Abstract: Xin Zhou,†,‡ Songyi Lee,† Zhaochao Xu,* and Juyoung Yoon*,† †Department of Chemistry and Nanoscience, Ewha Womans University, Seoul 120-750, Republic of Korea ‡Research Center for Chemical Biology, Department of Chemistry, Yanbian University, Yanjii 133002, People’s Republic of China Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Shahekou, Dalian, Liaoning, People’s Republic of China

631 citations

Journal ArticleDOI
14 Mar 2019-Sensors
TL;DR: An overview of the recent progress made in a wide range of gas-sensing technology is presented, including the sensing functionalizing materials, the advanced micro-machining fabrication methods, as well as their constraints on the sensor design.
Abstract: Micro- and nano-sensors lie at the heart of critical innovation in fields ranging from medical to environmental sciences. In recent years, there has been a significant improvement in sensor design along with the advances in micro- and nano-fabrication technology and the use of newly designed materials, leading to the development of high-performance gas sensors. Advanced micro- and nano-fabrication technology enables miniaturization of these sensors into micro-sized gas sensor arrays while maintaining the sensing performance. These capabilities facilitate the development of miniaturized integrated gas sensor arrays that enhance both sensor sensitivity and selectivity towards various analytes. In the past, several micro- and nano-gas sensors have been proposed and investigated where each type of sensor exhibits various advantages and limitations in sensing resolution, operating power, response, and recovery time. This paper presents an overview of the recent progress made in a wide range of gas-sensing technology. The sensing functionalizing materials, the advanced micro-machining fabrication methods, as well as their constraints on the sensor design, are discussed. The sensors’ working mechanisms and their structures and configurations are reviewed. Finally, the future development outlook and the potential applications made feasible by each category of the sensors are discussed.

332 citations

Journal ArticleDOI
TL;DR: The presented results prove the CMUT as a MEMS technology for many medical diagnostic and therapeutic applications as well as the progression of developing several generations of fabrication processes.
Abstract: Capacitive micromachined ultrasonic transducers (CMUTs) have been subject to extensive research for the last two decades. Although they were initially developed for air-coupled applications, today their main application space is medical imaging and therapy. This paper first presents a brief description of CMUTs, their basic structure and operating principles. Our progression of developing several generations of fabrication processes is discussed with an emphasis on the advantages and disadvantages of each process. Monolithic and hybrid approaches for integrating CMUTs with supporting integrated circuits are surveyed. Several prototype transducer arrays with integrated front-end electronic circuits we developed and their use for 2D and 3D, anatomical and functional imaging, and ablative therapies are described. The presented results prove the CMUT as a micro-electro-mechanical systems technology for many medical diagnostic and therapeutic applications.

290 citations