scispace - formally typeset
Search or ask a question
Author

Masaaki Nakai

Other affiliations: Nagoya University, Tohoku University
Bio: Masaaki Nakai is an academic researcher from Kindai University. The author has contributed to research in topics: Titanium alloy & Ultimate tensile strength. The author has an hindex of 32, co-authored 232 publications receiving 4278 citations. Previous affiliations of Masaaki Nakai include Nagoya University & Tohoku University.


Papers
More filters
Journal ArticleDOI
TL;DR: The development of new metallic alloys for biomedical applications is described in this paper, which includes β-type titanium alloys with a self-tunable modulus, which has been proposed for the construction of removable implants.

1,154 citations

Journal ArticleDOI
TL;DR: Effective methods to improve the static and dynamic strength while maintaining low Young's modulus for β-type titanium alloys used in biomedical applications are discussed.
Abstract: β-type titanium alloys with low Young's modulus are required to inhibit bone atrophy and enhance bone remodeling for implants used to substitute failed hard tissue. At the same time, these titanium alloys are required to have high static and dynamic strength. On the other hand, metallic biomaterials with variable Young's modulus are required to satisfy the needs of both patients and surgeons, namely, low and high Young's moduli, respectively. In this paper, we have discussed effective methods to improve the static and dynamic strength while maintaining low Young's modulus for β-type titanium alloys used in biomedical applications. Then, the advantage of low Young's modulus of β-type titanium alloys in biomedical applications has been discussed from the perspective of inhibiting bone atrophy and enhancing bone remodeling. Further, we have discussed the development of β-type titanium alloys with a self-adjusting Young's modulus for use in removable implants.

488 citations

Journal ArticleDOI
TL;DR: The microstructures, Young's moduli and tensile properties of the alloys were systemically examined to investigate the effects of deformation-induced ω phase transformation on their mechanical properties and Ti-17Mo alloy is considered to be a potential candidate for the spinal rods in spinal fixation devices.

150 citations

Journal ArticleDOI
TL;DR: The surface oxide film on a Ti-29Nb-13Ta-4.6Zr alloy (TNTZ) was precisely characterized using X-ray photoelectron spectroscopy (XPS) and Auger electron spectrography (AES) to understand the composition and chemical state of the surface oxide films of TNTZ as discussed by the authors.

126 citations

Journal ArticleDOI
TL;DR: In this paper, the effect of Mo addition on the microstructures, Young's moduli, and tensile properties of Ti-30Zr-(0, 8 ¼% Mo) alloys was investigated.

107 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: In this article, the most critical challenges for metallic implant biomaterials are summarized, with emphasis on the most promising approaches and strategies, and the properties that affect biocompatibility and mechanical integrity are discussed in detail.
Abstract: Human tissue is structured mainly of self-assembled polymers (proteins) and ceramics (bone minerals), with metals present as trace elements with molecular scale functions. However, metals and their alloys have played a predominant role as structural biomaterials in reconstructive surgery, especially orthopedics, with more recent uses in non-osseous tissues, such as blood vessels. With the successful routine use of a large variety of metal implants clinically, issues associated with long-term maintenance of implant integrity have also emerged. This review focuses on metallic implant biomaterials, identifying and discussing critical issues in their clinical applications, including the systemic toxicity of released metal ions due to corrosion, fatigue failure of structural components due to repeated loading, and wearing of joint replacements due to movement. This is followed by detailed reviews on specific metallic biomaterials made from stainless steels, alloys of cobalt, titanium and magnesium, as well as shape memory alloys of nickel–titanium, silver, tantalum and zirconium. For each, the properties that affect biocompatibility and mechanical integrity (especially corrosion fatigue) are discussed in detail. Finally, the most critical challenges for metallic implant biomaterials are summarized, with emphasis on the most promising approaches and strategies.

1,575 citations

Journal ArticleDOI
TL;DR: The development of new metallic alloys for biomedical applications is described in this paper, which includes β-type titanium alloys with a self-tunable modulus, which has been proposed for the construction of removable implants.

1,154 citations

Journal ArticleDOI
Mitsuo Niinomi1
TL;DR: The following are described with regard to biomedical applications of titanium alloys: the Young's modulus, wear properties, notch fatigue strength, fatigue behaviour on relation to ageing treatment, and multifunctional deformation behaviours of Titanium alloys.
Abstract: Young's modulus as well as tensile strength, ductility, fatigue life, fretting fatigue life, wear properties, functionalities, etc., should be adjusted to levels that are suitable for structural biomaterials used in implants that replace hard tissue. These factors may be collectively referred to as mechanical biocompatibilities. In this paper, the following are described with regard to biomedical applications of titanium alloys: the Young's modulus, wear properties, notch fatigue strength, fatigue behaviour on relation to ageing treatment, improvement of fatigue strength, fatigue crack propagation resistance and ductility by the deformation-induced martensitic transformation of the unstable beta phase, and multifunctional deformation behaviours of titanium alloys.

1,022 citations

Book ChapterDOI
02 Mar 2001

984 citations