scispace - formally typeset
Search or ask a question
Author

Masaki Sekine

Bio: Masaki Sekine is an academic researcher from Tsukuba International University. The author has contributed to research in topics: Wearable computer & Fractal analysis. The author has an hindex of 9, co-authored 22 publications receiving 1147 citations. Previous affiliations of Masaki Sekine include University of Tsukuba & Tokyo Denki University.

Papers
More filters
Journal ArticleDOI
TL;DR: A review of wearable pulse rate sensors with green LEDs can be found in this paper. But, the authors do not discuss the application of these sensors in the medical field. But, they briefly present the history of wearable PPG and recent developments in wearable pulse-rate sensors.
Abstract: Photoplethysmography (PPG) technology has been used to develop small, wearable, pulse rate sensors. These devices, consisting of infrared light-emitting diodes (LEDs) and photodetectors, offer a simple, reliable, low-cost means of monitoring the pulse rate noninvasively. Recent advances in optical technology have facilitated the use of high-intensity green LEDs for PPG, increasing the adoption of this measurement technique. In this review, we briefly present the history of PPG and recent developments in wearable pulse rate sensors with green LEDs. The application of wearable pulse rate monitors is discussed.

700 citations

Journal ArticleDOI
01 Sep 2002
TL;DR: The results suggest that the acceleration signals change into a more complex pattern with aging and with Parkinson's disease, and the fractal dimension can be used to evaluate the gait of elderly subjects and patients with Parkinson’s disease.
Abstract: In this paper, we attempted to classify the acceleration signals for walking along a corridor and on stairs by using the wavelet-based fractal analysis method. In addition, the wavelet-based fractal analysis method was used to evaluate the gait of elderly subjects and patients with Parkinson's disease. The triaxial acceleration signals were measured close to the center of gravity of the body while the subject walked along a corridor and up and down stairs continuously. Signal measurements were recorded from 10 healthy young subjects and 11 elderly subjects. For comparison, two patients with Parkinson's disease participated in the level walking. The acceleration signal in each direction was decomposed to seven detailed signals at different wavelet scales by using the discrete wavelet transform. The variances of detailed signals at scales 7 to 1 were calculated. The fractal dimension of the acceleration signal was then estimated from the slope of the variance progression. The fractal dimensions were significantly different among the three types of walking for individual subjects (p < 0.01) and showed a high reproducibility. Our results suggest that the fractal dimensions are effective for classifying the walking types. Moreover, the fractal dimensions were significantly higher for the elderly subjects than for the young subjects (p < 0.01). For the patients with Parkinson's disease, the fractal dimensions tended to be higher than those of healthy subjects. These results suggest that the acceleration signals change into a more complex pattern with aging and with Parkinson's disease, and the fractal dimension can be used to evaluate the gait of elderly subjects and patients with Parkinson's disease.

213 citations

Journal ArticleDOI
TL;DR: A triaxial accelerometer was fixed to the subject's waist and the three acceleration signals were recorded by a portable data logger at a sampling rate of 256 Hz to distinguish walking on level ground from walking on a stairway using waist acceleration signals.

138 citations

Proceedings ArticleDOI
23 Jul 2000
TL;DR: It was possible to classify the walking pattern using acceleration signals in elderly people and walking up stairs could be distinguished by the smallest value in RPA from other walking patterns.
Abstract: We attempted to classify walking on level ground from walking on a stairway using a waist acceleration signal. A tri-axial accelerometer was fixed to the subject's waist and the three acceleration signals were recorded by a portable data logger at a sampling rate of 256 Hz. Eleven healthy, elderly subjects were asked to walk through a corridor and up and down a stairway as a single sequence, without any instruction. The data were analyzed using a discrete wavelet transform. Walking patterns were classified using two parameters; one was the ratio between the power of wavelet coefficients which were corresponded to locomotion and total power in the anteroposterior direction (RPA). The other was the ratio between root mean square of wavelet coefficients at the anteroposterior direction and that at the vertical direction (RAV). Walking up stairs could be distinguished by the smallest value in RPA from other walking patterns. Walking down stairs could be discriminated from level walking using RAV. It was possible to classify the walking pattern using acceleration signals in elderly people.

75 citations

Journal ArticleDOI
TL;DR: The proposed system consists of an electrocardiograph, a photoplethysmograph, and a control circuit with a Bluetooth module, all of which are mounted on a common armchair to measure ECG and PPG signals from users while sitting on the armchair in order to calculate continuous PAT.
Abstract: In this paper, we present an unobtrusive cuffless blood pressure (BP) monitoring system based on pulse arrival time (PAT) for facilitating long-term home BP monitoring. The proposed system consists of an electrocardiograph (ECG), a photoplethysmograph (PPG), and a control circuit with a Bluetooth module, all of which are mounted on a common armchair to measure ECG and PPG signals from users while sitting on the armchair in order to calculate continuous PAT. Considering the good linear correlation of systolic BP (SBP) and the nonlinear correlation of diastolic BP (DBP) with PAT, a new BP estimation method was proposed. Ten subjects underwent BP monitoring experiments involving stationary sitting on a chair, lying on a bed, and pedaling using an ergometer in order to assess the accuracy of the estimated BP. A cuff-type BP monitor was used as reference in the experiments. Results showed that the mean difference of the estimated SBP and DBP was within 0.2 ± 5.8 mmHg ( $p$ $p$ < 0.00001), respectively, and the mean absolute difference of the estimated SBP and DBP were 4.4 and 4.6 mmHg, respectively, compared to references. Additionally, five subjects participated in data collections consisting of sitting on a chair twice a day for one month. Compared to the reference, the difference did not obviously increase along with time, even though individualized calibration was executed only once at the beginning. These results suggest that the proposed system has quite the potential for long-term home BP monitoring.

66 citations


Cited by
More filters
Journal ArticleDOI
01 Jan 2006
TL;DR: Results demonstrate the feasibility of implementing an accelerometry-based, real-time movement classifier using embedded intelligence.
Abstract: The real-time monitoring of human movement can provide valuable information regarding an individual's degree of functional ability and general level of activity. This paper presents the implementation of a real-time classification system for the types of human movement associated with the data acquired from a single, waist-mounted triaxial accelerometer unit. The major advance proposed by the system is to perform the vast majority of signal processing onboard the wearable unit using embedded intelligence. In this way, the system distinguishes between periods of activity and rest, recognizes the postural orientation of the wearer, detects events such as walking and falls, and provides an estimation of metabolic energy expenditure. A laboratory-based trial involving six subjects was undertaken, with results indicating an overall accuracy of 90.8% across a series of 12 tasks (283 tests) involving a variety of movements related to normal daily activities. Distinction between activity and rest was performed without error; recognition of postural orientation was carried out with 94.1% accuracy, classification of walking was achieved with less certainty (83.3% accuracy), and detection of possible falls was made with 95.6% accuracy. Results demonstrate the feasibility of implementing an accelerometry-based, real-time movement classifier using embedded intelligence

1,334 citations

Journal ArticleDOI
TL;DR: The latest reported systems on activity monitoring of humans based on wearable sensors and issues to be addressed to tackle the challenges are reviewed.
Abstract: An increase in world population along with a significant aging portion is forcing rapid rises in healthcare costs. The healthcare system is going through a transformation in which continuous monitoring of inhabitants is possible even without hospitalization. The advancement of sensing technologies, embedded systems, wireless communication technologies, nano technologies, and miniaturization makes it possible to develop smart systems to monitor activities of human beings continuously. Wearable sensors detect abnormal and/or unforeseen situations by monitoring physiological parameters along with other symptoms. Therefore, necessary help can be provided in times of dire need. This paper reviews the latest reported systems on activity monitoring of humans based on wearable sensors and issues to be addressed to tackle the challenges.

1,117 citations

Journal ArticleDOI
20 Aug 2010-Sensors
TL;DR: This paper reviews and compares existing commercial products to provide a comprehensive outlook of current development status and possible emerging technologies of wearable accelerometry-based motion detectors.
Abstract: Characteristics of physical activity are indicative of one's mobility level, latent chronic diseases and aging process. Accelerometers have been widely accepted as useful and practical sensors for wearable devices to measure and assess physical activity. This paper reviews the development of wearable accelerometry-based motion detectors. The principle of accelerometry measurement, sensor properties and sensor placements are first introduced. Various research using accelerometry-based wearable motion detectors for physical activity monitoring and assessment, including posture and movement classification, estimation of energy expenditure, fall detection and balance control evaluation, are also reviewed. Finally this paper reviews and compares existing commercial products to provide a comprehensive outlook of current development status and possible emerging technologies.

937 citations

Journal ArticleDOI
TL;DR: The ambulatory system showed a very high accuracy (> 99%) in identifying the 62 transfers or rolling out of bed, as well as 144 different posture changes to the back, ventral, right and left sides, in both first and second studies.
Abstract: A new method of physical activity monitoring is presented, which is able to detect body postures (sifting, standing, and lying) and periods of walking in elderly persons using only one kinematic sensor attached to the chest. The wavelet transform, in conjunction with a simple kinematics model, was used to detect different postural transitions (PTs) and walking periods during daily physical activity. To evaluate the system, three studies were performed. The method was first tested on 11 community-dwelling elderly subjects in a gait laboratory where an optical motion system (Vicon) was used as a reference system. In the second study, the system was tested for classifying PTs (i.e., lying-to-sitting, sitting-to-lying, and turning the body in bed) in 24 hospitalized elderly persons. Finally, in a third study monitoring was performed on nine elderly persons for 45-60 min during their daily physical activity. Moreover, the possibility-to-perform long-term monitoring over 12 h has been shown. The first study revealed a close concordance between the ambulatory and reference systems. Overall, subjects performed 349 PTs during this study. Compared with the reference system, the ambulatory system had an overall sensitivity of 99% for detection of the different PTs. Sensitivities and specificities were 93% and 82% in sit-to-stand, and 82% and 94% in stand-to-sit, respectively. In both first and second studies, the ambulatory system also showed a very high accuracy (> 99%) in identifying the 62 transfers or rolling out of bed, as well as 144 different posture changes to the back, ventral, right and left sides. Relatively high sensitivity (> 90%) was obtained for the classification of usual physical activities in the third study in comparison with visual observation. Sensitivities and specificities were, respectively, 90.2% and 93.4% in sitting, 92.2% and 92.1% in "standing + walking," and, finally, 98.4% and 99.7% in lying. Overall detection errors (as percent of range) were 3.9% for "standing + walking," 4.1% for sitting, and 0.3% for lying. Finally, overall symmetric mean average errors were 12% for "standing + walking." 8.2% for sifting, and 1.3% for lying.

778 citations

Journal ArticleDOI
TL;DR: An integrated approach is described in which a single, waist-mounted accelerometry system is used to monitor a range of different parameters of human movement in an unsupervised setting.
Abstract: Accelerometry offers a practical and low cost method of objectively monitoring human movements, and has particular applicability to the monitoring of free-living subjects. Accelerometers have been used to monitor a range of different movements, including gait, sit-to-stand transfers, postural sway and falls. They have also been used to measure physical activity levels and to identify and classify movements performed by subjects. This paper reviews the use of accelerometer-based systems in each of these areas. The scope and applicability of such systems in unsupervised monitoring of human movement are considered. The different systems and monitoring techniques can be integrated to provide a more comprehensive system that is suitable for measuring a range of different parameters in an unsupervised monitoring context with free-living subjects. An integrated approach is described in which a single, waist-mounted accelerometry system is used to monitor a range of different parameters of human movement in an unsupervised setting.

735 citations