Proceedings ArticleDOI
04 May 1994
TL;DR: In this paper, the authors evaluate the air cooling characteristics of plate fins for MCMs (multichip modules) with and without some spanwise space around the plate fins, and propose empirical equations for the Nusselt number and friction factor based on the numerical results.
Abstract: Numerical and experimental studies were carried out to evaluate the air cooling characteristics of plate fins for MCMs (multichip modules) with and without some spanwise space around the plate fins. The flow field in-between the plate fins can be assumed to be similar to that of a parallel plate duct, and hence two dimensional laminar flow analyses using the finite volume method were performed. Calculations were carried out for Res (S/L)=1 to 200 and S/t (plate spacing to plate thickness ratio)=3, 4 and 7. Some empirical equations for the Nusselt number and friction factor based on the numerical results are proposed. Considering the fin efficiency calculated from the conventional conduction fin model, the thermal resistance of the plate fins with no space around the fins could be estimated easily on the basis of the above-mentioned equations. Comparisons with experimental results show that this method is valid for H/S (fin height to plate spacing ratio)/spl ges/7. In the case of H/S=4, the thermal resistance is overestimated by this method. Furthermore, nodal network analyses were carried out to estimate the thermal resistance of the plate fin including some spanwise space by specifying the cooling characteristics of the plate fin with no space around the fin. The good agreement between the predicted results and corresponding experimental data shows that this relatively simple nodal network method is quite useful to estimate the thermal resistance of plate fills including some spanwise space. >

34 citations

Journal ArticleDOI
29 May 1996
TL;DR: In this article, a numerical simulation was carried out on the flow and the temperature fields around a plate fin array subjected to a uniform flow, varying the ratio of fin length L to the half-pitch of fin s. The results showed that frictional resistance and heat transfer of the fin array showed excellent agreement with those for the developing flow between parallel plates with uniform inlet flow velocity equal to U/sub f/.
Abstract: Numerical simulation was carried out on the flow and the temperature fields around a plate fin array subjected to a uniform flow, varying the ratio of fin length L to the half-pitch of fins s. As Re/sub 0/s/L decreased, the flow approaching the fin array had a tendency to bypass it and thus the average flow velocity through fins U/sub f/ became lower, where Re/sub 0/ is the Reynolds number defined by uniform flow velocity and s. It was also found that frictional resistance and heat transfer of the fins showed excellent agreement with those for the developing flow between parallel plates with uniform inlet flow velocity equal to U/sub f/. A prediction technique for the cooling performance of the array was developed in which U/sub f/ was estimated under the condition of constant pressure distribution at its downstream edge. The present technique can predict the heat transfer of the fin array with an error level below 30% under practical conditions of electronics design, although it underestimates U/sub f/ in the region of small Re/sub 0/s/L.

31 citations

Proceedings ArticleDOI
Hideo Iwasaki1, Masaru Ishizuka1
23 May 2000
TL;DR: In this article, a three-dimensional laminar flow simulation was carried out in order to investigate forced convection air cooling characteristics of compact plate fin arrays expected to be used for cooling notebook personal computers under the condition for which the fin tips were shrouded and no spanwise space around the fins was provided.
Abstract: Three-dimensional laminar flow simulation was carried out in order to investigate forced convection air cooling characteristics of compact plate fin arrays expected to be used for cooling notebook personal computers under the condition for which the fin tips were shrouded and no spanwise space around the fins was provided. The numerical simulation was performed by considering a conjugate problem which solved both flow and heat transfer in air stream and heat conduction in the fins and fin bases. Numerical results showed that the average heat transfer coefficient of the fin base was approximately one half of that of the fin. Based on the results of computation, some empirical equations for average Nusselt number of the fins and the fin bases and the friction factor were proposed as a function of Reynolds number. Using the fin efficiency calculated on the basis of the conventional conduction fin model, the thermal resistance of the plate fins could be estimated easily on the basis of the above-mentioned equations within an error level of 5% compared with the numerical results. The results also led to an important finding that there existed an optimum fin spacing fora given heat flux which could minimize blowing power.

16 citations

Patent
31 Mar 1989
TL;DR: A semiconductor switching apparatus includes a member for radiating heat generated from semiconductor switches and for reducing a thermal stress as mentioned in this paper, and the lengths of gate electrode wires are equally set.
Abstract: A semiconductor switching apparatus includes a member for radiating heat generated from semiconductor switching element chips and for reducing a thermal stress. The lengths of gate electrode wires are equally set. The semiconductor switching apparatus has a large capacity and good switching characteristics.

13 citations


Cited by
More filters
Journal ArticleDOI
TL;DR: The use of latent heat thermal energy storage for thermally buffering vehicle systems is reviewed in this article, where the authors identify material candidates for each vehicle system based on system temperature, specific and volumetric latent heat and thermal conductivity.

331 citations

Patent
02 Apr 1997
TL;DR: A chip scale ball grid array for integrated circuit packaging has a non-polymer layer or support structure positioned between a semiconductor die and a substrate as discussed by the authors, which acts to increase circuit reliability by reducing thermal stress effects and/or by reducing or eliminating formation of voids in an integrated circuit package.
Abstract: A chip scale ball grid array for integrated circuit packaging having a nonpolymer layer or support structure positioned between a semiconductor die and a substrate. The nonpolymer support structure acts to increase circuit reliability by reducing thermal stress effects and/or by reducing or eliminating formation of voids in an integrated circuit package. A nonpolymer support structure may be a material, such as copper foil, having sufficient rigidity to allow processing of chip scale package in strip format.

295 citations

Journal ArticleDOI
TL;DR: The electrical applications of carbons and their composites are reviewed in this paper, with emphasis on applications that are relevant to industrial needs, such as electrical conduction, electrical contacts, electrodes, electromagnetic interference shielding, resistance heating, thermoelectricity, sensing, electrical switching, electronic devices and thermal pastes.
Abstract: The electrical applications of carbons and their composites are reviewed, with emphasis on applications that are relevant to industrial needs. The applications include electrical conduction, electrical contacts, electrodes, electromagnetic interference shielding, resistance heating, thermoelectricity, sensing, electrical switching, electronic devices and thermal pastes. The carbons include graphite, coke, carbon fibers, carbon filaments, carbon black and flexible graphite.

293 citations

Journal ArticleDOI
TL;DR: In this paper, a wind tunnel test with seven types of heat sinks including plate fin, strip fin, and pin fin heat sinks was conducted in order to evaluate the Nusselt number and dimensionless pressure drop.
Abstract: Tests have been conducted in a wind tunnel with seven types of heat sinks including plate fin, strip fin, and pin fin heat sinks. In the case of strip fin, and pin fin heat sinks, both in-line and staggered arrays have been studied. The pin fin heat sinks had circular and square cross-sections. For each type, tests were run with fin heights (H) of 10, 15, and 20 mm while the heat sink width (B) was kept constant and equal to 52.8 mm. In total, 42 different heat sinks were tested. The width of the wind tunnel duct (CB) was varied in such a way that results were obtained for B/CB=0.84, 0.53, and 0.33. The wind tunnel height (CH) was varied similarly, and data were recorded for H/CH=1, 0.67, and 0.33 while the duct Reynolds number was varied between 2000 through 16500. An empirical bypass correlation has been developed for the different fin designs. The correlation predicts the Nusselt number and the dimensionless pressure drop and takes into account the influence of duct height, duct width, fin height, fin thickness, and fin-to-fin distance. The correlation parameters are individual for each fin design. Further, a physical bypass model for plate fin heat sinks has been developed to describe the bypass effect.

127 citations

Journal ArticleDOI
01 Jan 2003-Carbon
TL;DR: Carbon black dispersions based on polyethylene glycol (PEG) or di(e glycol) butyl ether, along with dissolved ethyl cellulose, provide thermal pastes that are superior to solder as thermal interface materials as mentioned in this paper.

124 citations